The first experience of the usage of leadless pacemaker in Ukraine

The article presents literature review about pacemakers of different generations. It is indicated that wire-type of pacemakers are accompanied by frequent local complications which are related to the system of electrodes, i.e. electrode fracture, electrode dislocation, subclavian vein thrombosis, ri...

Full description

Saved in:
Bibliographic Details
Main Authors: O.M. Grytsay, Ya.V. Skybchyk, E.V. Zhytynskyi, V.O. Kuts, O.J. Zharinov
Format: Article
Language:English
Published: TOV Chetverta Khvylia 2020-06-01
Series:Кардіохірургія та інтервенційна кардіологія
Subjects:
Online Access:http://csic.com.ua/images/pdf/2020/2-2020/first-experience-of-usage-leadless-pacemaker-in-ukraine.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832569460325613568
author O.M. Grytsay
Ya.V. Skybchyk
E.V. Zhytynskyi
V.O. Kuts
O.J. Zharinov
author_facet O.M. Grytsay
Ya.V. Skybchyk
E.V. Zhytynskyi
V.O. Kuts
O.J. Zharinov
author_sort O.M. Grytsay
collection DOAJ
description The article presents literature review about pacemakers of different generations. It is indicated that wire-type of pacemakers are accompanied by frequent local complications which are related to the system of electrodes, i.e. electrode fracture, electrode dislocation, subclavian vein thrombosis, right ventricle perforation resulting in hemopericardium, pneumothorax and infectious complications. Failure rates and technical issues are reported up to 0.1–1.5 % per year. Medtronic Micra leadless pacemaker has shown safety and efficacy at short term and during prospective monitoring as an alternative to traditional pacemakers. This technology demonstrates important perspectives in cardiac rhythm control. In Ukraine, on the basis of the Heart Institute, Ministry of Health of Ukraine, 12 successful surgical interventions were conducted using Medtronic Micra.
format Article
id doaj-art-66fde59b66ef4ff6bb0fde58ed2ad461
institution Kabale University
issn 2305-3127
language English
publishDate 2020-06-01
publisher TOV Chetverta Khvylia
record_format Article
series Кардіохірургія та інтервенційна кардіологія
spelling doaj-art-66fde59b66ef4ff6bb0fde58ed2ad4612025-02-02T21:03:53ZengTOV Chetverta KhvyliaКардіохірургія та інтервенційна кардіологія2305-31272020-06-0123641http://doi.org/10.31928/2305-3127-2020.2.3641The first experience of the usage of leadless pacemaker in UkraineO.M. Grytsay0Ya.V. Skybchyk1E.V. Zhytynskyi2V.O. Kuts3O.J. Zharinov4Heart Institute, Ministry of Health of Ukraine, Kyiv, UkraineHeart Institute, Ministry of Health of Ukraine, Kyiv, Ukraine, Shupyk National Medical Academy of Postgraduate Education, Kyiv, UkraineHeart Institute, Ministry of Health of Ukraine, Kyiv, UkraineShupyk National Medical Academy of Postgraduate Education, Kyiv, UkraineShupyk National Medical Academy of Postgraduate Education, Kyiv, UkraineThe article presents literature review about pacemakers of different generations. It is indicated that wire-type of pacemakers are accompanied by frequent local complications which are related to the system of electrodes, i.e. electrode fracture, electrode dislocation, subclavian vein thrombosis, right ventricle perforation resulting in hemopericardium, pneumothorax and infectious complications. Failure rates and technical issues are reported up to 0.1–1.5 % per year. Medtronic Micra leadless pacemaker has shown safety and efficacy at short term and during prospective monitoring as an alternative to traditional pacemakers. This technology demonstrates important perspectives in cardiac rhythm control. In Ukraine, on the basis of the Heart Institute, Ministry of Health of Ukraine, 12 successful surgical interventions were conducted using Medtronic Micra.http://csic.com.ua/images/pdf/2020/2-2020/first-experience-of-usage-leadless-pacemaker-in-ukraine.pdfmedtronic micraleadless pacemakermicra-idepar-micra
spellingShingle O.M. Grytsay
Ya.V. Skybchyk
E.V. Zhytynskyi
V.O. Kuts
O.J. Zharinov
The first experience of the usage of leadless pacemaker in Ukraine
Кардіохірургія та інтервенційна кардіологія
medtronic micra
leadless pacemaker
micra-ide
par-micra
title The first experience of the usage of leadless pacemaker in Ukraine
title_full The first experience of the usage of leadless pacemaker in Ukraine
title_fullStr The first experience of the usage of leadless pacemaker in Ukraine
title_full_unstemmed The first experience of the usage of leadless pacemaker in Ukraine
title_short The first experience of the usage of leadless pacemaker in Ukraine
title_sort first experience of the usage of leadless pacemaker in ukraine
topic medtronic micra
leadless pacemaker
micra-ide
par-micra
url http://csic.com.ua/images/pdf/2020/2-2020/first-experience-of-usage-leadless-pacemaker-in-ukraine.pdf
work_keys_str_mv AT omgrytsay thefirstexperienceoftheusageofleadlesspacemakerinukraine
AT yavskybchyk thefirstexperienceoftheusageofleadlesspacemakerinukraine
AT evzhytynskyi thefirstexperienceoftheusageofleadlesspacemakerinukraine
AT vokuts thefirstexperienceoftheusageofleadlesspacemakerinukraine
AT ojzharinov thefirstexperienceoftheusageofleadlesspacemakerinukraine
AT omgrytsay firstexperienceoftheusageofleadlesspacemakerinukraine
AT yavskybchyk firstexperienceoftheusageofleadlesspacemakerinukraine
AT evzhytynskyi firstexperienceoftheusageofleadlesspacemakerinukraine
AT vokuts firstexperienceoftheusageofleadlesspacemakerinukraine
AT ojzharinov firstexperienceoftheusageofleadlesspacemakerinukraine