The first experience of the usage of leadless pacemaker in Ukraine
The article presents literature review about pacemakers of different generations. It is indicated that wire-type of pacemakers are accompanied by frequent local complications which are related to the system of electrodes, i.e. electrode fracture, electrode dislocation, subclavian vein thrombosis, ri...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
TOV Chetverta Khvylia
2020-06-01
|
Series: | Кардіохірургія та інтервенційна кардіологія |
Subjects: | |
Online Access: | http://csic.com.ua/images/pdf/2020/2-2020/first-experience-of-usage-leadless-pacemaker-in-ukraine.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832569460325613568 |
---|---|
author | O.M. Grytsay Ya.V. Skybchyk E.V. Zhytynskyi V.O. Kuts O.J. Zharinov |
author_facet | O.M. Grytsay Ya.V. Skybchyk E.V. Zhytynskyi V.O. Kuts O.J. Zharinov |
author_sort | O.M. Grytsay |
collection | DOAJ |
description | The article presents literature review about pacemakers of different generations. It is indicated that wire-type of pacemakers are accompanied by frequent local complications which are related to the system of electrodes, i.e. electrode fracture, electrode dislocation, subclavian vein thrombosis, right ventricle perforation resulting in hemopericardium, pneumothorax and infectious complications. Failure rates and technical issues are reported up to 0.1–1.5 % per year. Medtronic Micra leadless pacemaker has shown safety and efficacy at short term and during prospective monitoring as an alternative to traditional pacemakers. This technology demonstrates important perspectives in cardiac rhythm control. In Ukraine, on the basis of the Heart Institute, Ministry of Health of Ukraine, 12 successful surgical interventions were conducted using Medtronic Micra. |
format | Article |
id | doaj-art-66fde59b66ef4ff6bb0fde58ed2ad461 |
institution | Kabale University |
issn | 2305-3127 |
language | English |
publishDate | 2020-06-01 |
publisher | TOV Chetverta Khvylia |
record_format | Article |
series | Кардіохірургія та інтервенційна кардіологія |
spelling | doaj-art-66fde59b66ef4ff6bb0fde58ed2ad4612025-02-02T21:03:53ZengTOV Chetverta KhvyliaКардіохірургія та інтервенційна кардіологія2305-31272020-06-0123641http://doi.org/10.31928/2305-3127-2020.2.3641The first experience of the usage of leadless pacemaker in UkraineO.M. Grytsay0Ya.V. Skybchyk1E.V. Zhytynskyi2V.O. Kuts3O.J. Zharinov4Heart Institute, Ministry of Health of Ukraine, Kyiv, UkraineHeart Institute, Ministry of Health of Ukraine, Kyiv, Ukraine, Shupyk National Medical Academy of Postgraduate Education, Kyiv, UkraineHeart Institute, Ministry of Health of Ukraine, Kyiv, UkraineShupyk National Medical Academy of Postgraduate Education, Kyiv, UkraineShupyk National Medical Academy of Postgraduate Education, Kyiv, UkraineThe article presents literature review about pacemakers of different generations. It is indicated that wire-type of pacemakers are accompanied by frequent local complications which are related to the system of electrodes, i.e. electrode fracture, electrode dislocation, subclavian vein thrombosis, right ventricle perforation resulting in hemopericardium, pneumothorax and infectious complications. Failure rates and technical issues are reported up to 0.1–1.5 % per year. Medtronic Micra leadless pacemaker has shown safety and efficacy at short term and during prospective monitoring as an alternative to traditional pacemakers. This technology demonstrates important perspectives in cardiac rhythm control. In Ukraine, on the basis of the Heart Institute, Ministry of Health of Ukraine, 12 successful surgical interventions were conducted using Medtronic Micra.http://csic.com.ua/images/pdf/2020/2-2020/first-experience-of-usage-leadless-pacemaker-in-ukraine.pdfmedtronic micraleadless pacemakermicra-idepar-micra |
spellingShingle | O.M. Grytsay Ya.V. Skybchyk E.V. Zhytynskyi V.O. Kuts O.J. Zharinov The first experience of the usage of leadless pacemaker in Ukraine Кардіохірургія та інтервенційна кардіологія medtronic micra leadless pacemaker micra-ide par-micra |
title | The first experience of the usage of leadless pacemaker in Ukraine |
title_full | The first experience of the usage of leadless pacemaker in Ukraine |
title_fullStr | The first experience of the usage of leadless pacemaker in Ukraine |
title_full_unstemmed | The first experience of the usage of leadless pacemaker in Ukraine |
title_short | The first experience of the usage of leadless pacemaker in Ukraine |
title_sort | first experience of the usage of leadless pacemaker in ukraine |
topic | medtronic micra leadless pacemaker micra-ide par-micra |
url | http://csic.com.ua/images/pdf/2020/2-2020/first-experience-of-usage-leadless-pacemaker-in-ukraine.pdf |
work_keys_str_mv | AT omgrytsay thefirstexperienceoftheusageofleadlesspacemakerinukraine AT yavskybchyk thefirstexperienceoftheusageofleadlesspacemakerinukraine AT evzhytynskyi thefirstexperienceoftheusageofleadlesspacemakerinukraine AT vokuts thefirstexperienceoftheusageofleadlesspacemakerinukraine AT ojzharinov thefirstexperienceoftheusageofleadlesspacemakerinukraine AT omgrytsay firstexperienceoftheusageofleadlesspacemakerinukraine AT yavskybchyk firstexperienceoftheusageofleadlesspacemakerinukraine AT evzhytynskyi firstexperienceoftheusageofleadlesspacemakerinukraine AT vokuts firstexperienceoftheusageofleadlesspacemakerinukraine AT ojzharinov firstexperienceoftheusageofleadlesspacemakerinukraine |