T2*-weighted imaging for detection of intracranial silicone oil in MRI obtained with motion correction sequences
Abstract Background For magnetic resonance imaging (MRI) findings of intracranial silicone oil migration, little has been described about images obtained with motion correction sequences such as MultiVane XD (Philips Healthcare) that provides high resolution diagnostic images even with severe patien...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
SpringerOpen
2025-02-01
|
Series: | Egyptian Journal of Neurosurgery |
Subjects: | |
Online Access: | https://doi.org/10.1186/s41984-025-00362-4 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1823862656161808384 |
---|---|
author | Ryuta Yasuda Masayuki Maeda Kenichi Takada Katsuhiro Inoue Masataka Sugao Hidenori Suzuki |
author_facet | Ryuta Yasuda Masayuki Maeda Kenichi Takada Katsuhiro Inoue Masataka Sugao Hidenori Suzuki |
author_sort | Ryuta Yasuda |
collection | DOAJ |
description | Abstract Background For magnetic resonance imaging (MRI) findings of intracranial silicone oil migration, little has been described about images obtained with motion correction sequences such as MultiVane XD (Philips Healthcare) that provides high resolution diagnostic images even with severe patient motion. We report a case with intracranial silicone oil migration in which MRI was obtained with MultiVane XD and T2*-weighted imaging (T2*WI) was found the most useful in detecting intracranial silicone oil. Case presentation A 77-year-old female with a history of eye surgery using silicone oil referred to our hospital due to conscious disturbance. Head computed tomography demonstrated multiple intracranial masses whose signal density was similar to that in the operated eyeball and the tentative diagnosis of intracranial silicone oil migration was made. MRI was performed with MultiVane XD due to the significant patient’s restlessness, and among all sequences including T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), fluid-attenuated inversion recovery (FLAIR) and T2*WI, only T2*WI detected intracranial silicone oil. In contrast, another MRI obtained previously with conventional turbo spin-echo detected intracranial silicone oil not only in T2*WI but also in T1WI, T2WI and FLAIR. Phantom experiment revealed that chemical shift artifact played an important role in discriminating silicone oil from artificial cerebrospinal fluid, which attenuated in MultiVane XD. However, T2*WI still showed good discrimination of silicone oil even using MultiVane XD because of susceptibility artifacts. Conclusion T2*WI was the best sequence to detect intracranial silicone oil in MRI obtained with motion correction sequences because of its ability to depict the susceptibility artifacts. |
format | Article |
id | doaj-art-6659880aae3d4c5c82c32a588a6aed90 |
institution | Kabale University |
issn | 2520-8225 |
language | English |
publishDate | 2025-02-01 |
publisher | SpringerOpen |
record_format | Article |
series | Egyptian Journal of Neurosurgery |
spelling | doaj-art-6659880aae3d4c5c82c32a588a6aed902025-02-09T12:25:20ZengSpringerOpenEgyptian Journal of Neurosurgery2520-82252025-02-014011610.1186/s41984-025-00362-4T2*-weighted imaging for detection of intracranial silicone oil in MRI obtained with motion correction sequencesRyuta Yasuda0Masayuki Maeda1Kenichi Takada2Katsuhiro Inoue3Masataka Sugao4Hidenori Suzuki5Department of Neurosurgery, Tohyama HospitalDepartment of Radiology, Tohyama HospitalDepartment of Radiology, Tohyama HospitalDepartment of Neuroradiology, Mie University Graduate School of MedicineDepartment of Internal Medicine, Tohyama HospitalDepartment of Neurosurgery, Mie University Graduate School of MedicineAbstract Background For magnetic resonance imaging (MRI) findings of intracranial silicone oil migration, little has been described about images obtained with motion correction sequences such as MultiVane XD (Philips Healthcare) that provides high resolution diagnostic images even with severe patient motion. We report a case with intracranial silicone oil migration in which MRI was obtained with MultiVane XD and T2*-weighted imaging (T2*WI) was found the most useful in detecting intracranial silicone oil. Case presentation A 77-year-old female with a history of eye surgery using silicone oil referred to our hospital due to conscious disturbance. Head computed tomography demonstrated multiple intracranial masses whose signal density was similar to that in the operated eyeball and the tentative diagnosis of intracranial silicone oil migration was made. MRI was performed with MultiVane XD due to the significant patient’s restlessness, and among all sequences including T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), fluid-attenuated inversion recovery (FLAIR) and T2*WI, only T2*WI detected intracranial silicone oil. In contrast, another MRI obtained previously with conventional turbo spin-echo detected intracranial silicone oil not only in T2*WI but also in T1WI, T2WI and FLAIR. Phantom experiment revealed that chemical shift artifact played an important role in discriminating silicone oil from artificial cerebrospinal fluid, which attenuated in MultiVane XD. However, T2*WI still showed good discrimination of silicone oil even using MultiVane XD because of susceptibility artifacts. Conclusion T2*WI was the best sequence to detect intracranial silicone oil in MRI obtained with motion correction sequences because of its ability to depict the susceptibility artifacts.https://doi.org/10.1186/s41984-025-00362-4Silicone oilIntracranial migrationT2*-weighted imagingMotion correction sequence |
spellingShingle | Ryuta Yasuda Masayuki Maeda Kenichi Takada Katsuhiro Inoue Masataka Sugao Hidenori Suzuki T2*-weighted imaging for detection of intracranial silicone oil in MRI obtained with motion correction sequences Egyptian Journal of Neurosurgery Silicone oil Intracranial migration T2*-weighted imaging Motion correction sequence |
title | T2*-weighted imaging for detection of intracranial silicone oil in MRI obtained with motion correction sequences |
title_full | T2*-weighted imaging for detection of intracranial silicone oil in MRI obtained with motion correction sequences |
title_fullStr | T2*-weighted imaging for detection of intracranial silicone oil in MRI obtained with motion correction sequences |
title_full_unstemmed | T2*-weighted imaging for detection of intracranial silicone oil in MRI obtained with motion correction sequences |
title_short | T2*-weighted imaging for detection of intracranial silicone oil in MRI obtained with motion correction sequences |
title_sort | t2 weighted imaging for detection of intracranial silicone oil in mri obtained with motion correction sequences |
topic | Silicone oil Intracranial migration T2*-weighted imaging Motion correction sequence |
url | https://doi.org/10.1186/s41984-025-00362-4 |
work_keys_str_mv | AT ryutayasuda t2weightedimagingfordetectionofintracranialsiliconeoilinmriobtainedwithmotioncorrectionsequences AT masayukimaeda t2weightedimagingfordetectionofintracranialsiliconeoilinmriobtainedwithmotioncorrectionsequences AT kenichitakada t2weightedimagingfordetectionofintracranialsiliconeoilinmriobtainedwithmotioncorrectionsequences AT katsuhiroinoue t2weightedimagingfordetectionofintracranialsiliconeoilinmriobtainedwithmotioncorrectionsequences AT masatakasugao t2weightedimagingfordetectionofintracranialsiliconeoilinmriobtainedwithmotioncorrectionsequences AT hidenorisuzuki t2weightedimagingfordetectionofintracranialsiliconeoilinmriobtainedwithmotioncorrectionsequences |