Comparative Study of Vault Measurement by Pentacam, Casia2, and RTVue in Myopic Eyes After Implantable Collamer Lens Implantation

Fang Liu,1– 4,* Yijia Xu,1– 4,* Yuhao Ye,1– 4 Zhe Zhang,1– 4 Lingling Niu,1– 4 Peijun Yao,1– 4 Xiaoying Wang,1– 4 Xingtao Zhou,1– 4 Jing Zhao1– 4 1Department of Ophthalmology and Optometry, Eye & ENT Hospital, Fudan University, Shanghai, People’s Republic of China; 2Key Laborator...

Full description

Saved in:
Bibliographic Details
Main Authors: Liu F, Xu Y, Ye Y, Zhang Z, Niu L, Yao P, Wang X, Zhou X, Zhao J
Format: Article
Language:English
Published: Dove Medical Press 2025-03-01
Series:Clinical Optometry
Subjects:
Online Access:https://www.dovepress.com/comparative-study-of-vault-measurement-by-pentacam-casia2-and-rtvue-in-peer-reviewed-fulltext-article-OPTO
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849707312964435968
author Liu F
Xu Y
Ye Y
Zhang Z
Niu L
Yao P
Wang X
Zhou X
Zhao J
author_facet Liu F
Xu Y
Ye Y
Zhang Z
Niu L
Yao P
Wang X
Zhou X
Zhao J
author_sort Liu F
collection DOAJ
description Fang Liu,1– 4,* Yijia Xu,1– 4,* Yuhao Ye,1– 4 Zhe Zhang,1– 4 Lingling Niu,1– 4 Peijun Yao,1– 4 Xiaoying Wang,1– 4 Xingtao Zhou,1– 4 Jing Zhao1– 4 1Department of Ophthalmology and Optometry, Eye & ENT Hospital, Fudan University, Shanghai, People’s Republic of China; 2Key Laboratory of Myopia and Related Eye Diseases, NHC, Shanghai, China; Key Laboratory of Myopia and Related Eye Diseases, Chinese Academy of Medical Sciences, Shanghai, People’s Republic of China; 3Shanghai Research Center of Ophthalmology and Optometry, Shanghai, People’s Republic of China; 4Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, People’s Republic of China*These authors contributed equally to this workCorrespondence: Jing Zhao; Xingtao Zhou, Department of Ophthalmology, Eye and ENT Hospital of Fudan University; NHC Key Laboratory of Myopia; Laboratory of Myopia, Chinese Academy of Medical Sciences, 83 Fenyang Road, Shanghai, 200031, People’s Republic of China, Tel +86-021-64377134, Email zhaojing_med@163.com; doctzhouxingtao@163.comPurpose: To compare vault measurement using Pentacam (Oculus, Germany) and two optical coherence tomography (OCT) instruments, Casia2 (Tomey Corporation, Japan) and RTVue (Optovue Inc. USA).Methods: This comparative study recruited 95 eyes of 50 patients (mean age: 28.40± 4.51, male/female 15/35) who underwent implantable collamer lens (ICL) implantation for myopia correction. All patients underwent a series of ophthalmic examinations at 3 and 6 months postoperatively, and the vault was measured using three instruments in the same order at both follow-ups. Intraclass coefficients (ICC) and Bland-Altman plots were used to analyze intra-equipment reproducibility and agreement between two instruments. A multivariate regression model was used to analyze the factors influencing the vault differences between the devices.Results: The ICC values for intra-observer and inter-observer reproducibility of each piece of equipment were above 0.9. The ICC values and mean differences of vault measurement of Casia2 vs Pentacam, Casia2 vs RTVue, and RTVue vs Pentacam were 0.763 and 139.81 μm, 0.960 and − 17.18 μm, 0.739 and 151.86 μm, respectively. An average of 96.2% of the points fell within the limit of agreement in the Bland-Altman plots. No difference was found in the inter-device agreement between the 3– and 6-month vaults. The difference in pupil diameter, anterior chamber depth, and anterior chamber angle could influence the vault difference between the Pentacam and the two OCT instruments.Conclusion: All three instruments demonstrated good intra-equipment reproducibility. Casia2 and RTVue showed excellent agreement in the vault measurements. The Pentacam’s vault readings were significantly lower than those measured by Casia2 and RTVue; therefore, their vault measurements were not interchangeable.Keywords: ICL implantation, vault, agreement, Pentacam, OCT
format Article
id doaj-art-6631d91e3abc4e408ece022a699bb8f8
institution DOAJ
issn 1179-2752
language English
publishDate 2025-03-01
publisher Dove Medical Press
record_format Article
series Clinical Optometry
spelling doaj-art-6631d91e3abc4e408ece022a699bb8f82025-08-20T03:15:57ZengDove Medical PressClinical Optometry1179-27522025-03-01Volume 176171100802Comparative Study of Vault Measurement by Pentacam, Casia2, and RTVue in Myopic Eyes After Implantable Collamer Lens ImplantationLiu FXu YYe YZhang ZNiu LYao PWang XZhou XZhao JFang Liu,1– 4,* Yijia Xu,1– 4,* Yuhao Ye,1– 4 Zhe Zhang,1– 4 Lingling Niu,1– 4 Peijun Yao,1– 4 Xiaoying Wang,1– 4 Xingtao Zhou,1– 4 Jing Zhao1– 4 1Department of Ophthalmology and Optometry, Eye & ENT Hospital, Fudan University, Shanghai, People’s Republic of China; 2Key Laboratory of Myopia and Related Eye Diseases, NHC, Shanghai, China; Key Laboratory of Myopia and Related Eye Diseases, Chinese Academy of Medical Sciences, Shanghai, People’s Republic of China; 3Shanghai Research Center of Ophthalmology and Optometry, Shanghai, People’s Republic of China; 4Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, People’s Republic of China*These authors contributed equally to this workCorrespondence: Jing Zhao; Xingtao Zhou, Department of Ophthalmology, Eye and ENT Hospital of Fudan University; NHC Key Laboratory of Myopia; Laboratory of Myopia, Chinese Academy of Medical Sciences, 83 Fenyang Road, Shanghai, 200031, People’s Republic of China, Tel +86-021-64377134, Email zhaojing_med@163.com; doctzhouxingtao@163.comPurpose: To compare vault measurement using Pentacam (Oculus, Germany) and two optical coherence tomography (OCT) instruments, Casia2 (Tomey Corporation, Japan) and RTVue (Optovue Inc. USA).Methods: This comparative study recruited 95 eyes of 50 patients (mean age: 28.40± 4.51, male/female 15/35) who underwent implantable collamer lens (ICL) implantation for myopia correction. All patients underwent a series of ophthalmic examinations at 3 and 6 months postoperatively, and the vault was measured using three instruments in the same order at both follow-ups. Intraclass coefficients (ICC) and Bland-Altman plots were used to analyze intra-equipment reproducibility and agreement between two instruments. A multivariate regression model was used to analyze the factors influencing the vault differences between the devices.Results: The ICC values for intra-observer and inter-observer reproducibility of each piece of equipment were above 0.9. The ICC values and mean differences of vault measurement of Casia2 vs Pentacam, Casia2 vs RTVue, and RTVue vs Pentacam were 0.763 and 139.81 μm, 0.960 and − 17.18 μm, 0.739 and 151.86 μm, respectively. An average of 96.2% of the points fell within the limit of agreement in the Bland-Altman plots. No difference was found in the inter-device agreement between the 3– and 6-month vaults. The difference in pupil diameter, anterior chamber depth, and anterior chamber angle could influence the vault difference between the Pentacam and the two OCT instruments.Conclusion: All three instruments demonstrated good intra-equipment reproducibility. Casia2 and RTVue showed excellent agreement in the vault measurements. The Pentacam’s vault readings were significantly lower than those measured by Casia2 and RTVue; therefore, their vault measurements were not interchangeable.Keywords: ICL implantation, vault, agreement, Pentacam, OCThttps://www.dovepress.com/comparative-study-of-vault-measurement-by-pentacam-casia2-and-rtvue-in-peer-reviewed-fulltext-article-OPTOicl implantationvaultagreementpentacamoct
spellingShingle Liu F
Xu Y
Ye Y
Zhang Z
Niu L
Yao P
Wang X
Zhou X
Zhao J
Comparative Study of Vault Measurement by Pentacam, Casia2, and RTVue in Myopic Eyes After Implantable Collamer Lens Implantation
Clinical Optometry
icl implantation
vault
agreement
pentacam
oct
title Comparative Study of Vault Measurement by Pentacam, Casia2, and RTVue in Myopic Eyes After Implantable Collamer Lens Implantation
title_full Comparative Study of Vault Measurement by Pentacam, Casia2, and RTVue in Myopic Eyes After Implantable Collamer Lens Implantation
title_fullStr Comparative Study of Vault Measurement by Pentacam, Casia2, and RTVue in Myopic Eyes After Implantable Collamer Lens Implantation
title_full_unstemmed Comparative Study of Vault Measurement by Pentacam, Casia2, and RTVue in Myopic Eyes After Implantable Collamer Lens Implantation
title_short Comparative Study of Vault Measurement by Pentacam, Casia2, and RTVue in Myopic Eyes After Implantable Collamer Lens Implantation
title_sort comparative study of vault measurement by pentacam casia2 and rtvue in myopic eyes after implantable collamer lens implantation
topic icl implantation
vault
agreement
pentacam
oct
url https://www.dovepress.com/comparative-study-of-vault-measurement-by-pentacam-casia2-and-rtvue-in-peer-reviewed-fulltext-article-OPTO
work_keys_str_mv AT liuf comparativestudyofvaultmeasurementbypentacamcasia2andrtvueinmyopiceyesafterimplantablecollamerlensimplantation
AT xuy comparativestudyofvaultmeasurementbypentacamcasia2andrtvueinmyopiceyesafterimplantablecollamerlensimplantation
AT yey comparativestudyofvaultmeasurementbypentacamcasia2andrtvueinmyopiceyesafterimplantablecollamerlensimplantation
AT zhangz comparativestudyofvaultmeasurementbypentacamcasia2andrtvueinmyopiceyesafterimplantablecollamerlensimplantation
AT niul comparativestudyofvaultmeasurementbypentacamcasia2andrtvueinmyopiceyesafterimplantablecollamerlensimplantation
AT yaop comparativestudyofvaultmeasurementbypentacamcasia2andrtvueinmyopiceyesafterimplantablecollamerlensimplantation
AT wangx comparativestudyofvaultmeasurementbypentacamcasia2andrtvueinmyopiceyesafterimplantablecollamerlensimplantation
AT zhoux comparativestudyofvaultmeasurementbypentacamcasia2andrtvueinmyopiceyesafterimplantablecollamerlensimplantation
AT zhaoj comparativestudyofvaultmeasurementbypentacamcasia2andrtvueinmyopiceyesafterimplantablecollamerlensimplantation