Operational Status Analysis and Optimization Suggestions of Typical Dust Collectors in Coal-Fired Power Plants

In this study, 287 typical coal-fired unit dust removal facilities in 72 power plants are selected to investigate the operation status and issues of dust collectors, and corresponding suggestions are given on optimization and efficiency improvement for different types of dust collectors: For dry ele...

Full description

Saved in:
Bibliographic Details
Main Authors: Zunqiang SUN, Chenghang ZHENG, Can ZHOU, Sheng WANG, Xiuyuan MA, Yike YE
Format: Article
Language:zho
Published: State Grid Energy Research Institute 2022-11-01
Series:Zhongguo dianli
Subjects:
Online Access:https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202205031
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850228626645057536
author Zunqiang SUN
Chenghang ZHENG
Can ZHOU
Sheng WANG
Xiuyuan MA
Yike YE
author_facet Zunqiang SUN
Chenghang ZHENG
Can ZHOU
Sheng WANG
Xiuyuan MA
Yike YE
author_sort Zunqiang SUN
collection DOAJ
description In this study, 287 typical coal-fired unit dust removal facilities in 72 power plants are selected to investigate the operation status and issues of dust collectors, and corresponding suggestions are given on optimization and efficiency improvement for different types of dust collectors: For dry electrostatic precipitators (ESPs), energy saving and efficiency improvement can be achieved by adjusting electric field rapping frequency, voltage reduction rapping and power intelligent control optimization; For low-low temperature ESPs, multi-scale and multi-field coupling simulation test of the whole process can solve the problems of wear and ash deposition, and the guide components can be reasonably arranged; For bag filters, airflow distribution optimization and intelligent regulation can solve the problem of bag breakage and high energy consumption; For wet ESPs, optimization of the electrode configuration can enhance the operational stability and reduce the frequency of electric field flashover.
format Article
id doaj-art-661b060da92c41618b4e77117d29ad13
institution OA Journals
issn 1004-9649
language zho
publishDate 2022-11-01
publisher State Grid Energy Research Institute
record_format Article
series Zhongguo dianli
spelling doaj-art-661b060da92c41618b4e77117d29ad132025-08-20T02:04:28ZzhoState Grid Energy Research InstituteZhongguo dianli1004-96492022-11-01551119420110.11930/j.issn.1004-9649.202205031zgdl-55-11-sunzunqiangOperational Status Analysis and Optimization Suggestions of Typical Dust Collectors in Coal-Fired Power PlantsZunqiang SUN0Chenghang ZHENG1Can ZHOU2Sheng WANG3Xiuyuan MA4Yike YE5National Environmental Protection Research Institute for Electric Power, Nanjing 210031, ChinaZhejiang University, Hangzhou 310027, ChinaZhejiang University, Hangzhou 310027, ChinaNational Environmental Protection Research Institute for Electric Power, Nanjing 210031, ChinaState Power Environmental Protection Research Institute, Nanjing 210031, ChinaState Power Environmental Protection Research Institute, Nanjing 210031, ChinaIn this study, 287 typical coal-fired unit dust removal facilities in 72 power plants are selected to investigate the operation status and issues of dust collectors, and corresponding suggestions are given on optimization and efficiency improvement for different types of dust collectors: For dry electrostatic precipitators (ESPs), energy saving and efficiency improvement can be achieved by adjusting electric field rapping frequency, voltage reduction rapping and power intelligent control optimization; For low-low temperature ESPs, multi-scale and multi-field coupling simulation test of the whole process can solve the problems of wear and ash deposition, and the guide components can be reasonably arranged; For bag filters, airflow distribution optimization and intelligent regulation can solve the problem of bag breakage and high energy consumption; For wet ESPs, optimization of the electrode configuration can enhance the operational stability and reduce the frequency of electric field flashover.https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202205031coal-fired power plantsdust collectorsoperation statusoptimization for efficiency improvementenergy saving for efficiency improvement
spellingShingle Zunqiang SUN
Chenghang ZHENG
Can ZHOU
Sheng WANG
Xiuyuan MA
Yike YE
Operational Status Analysis and Optimization Suggestions of Typical Dust Collectors in Coal-Fired Power Plants
Zhongguo dianli
coal-fired power plants
dust collectors
operation status
optimization for efficiency improvement
energy saving for efficiency improvement
title Operational Status Analysis and Optimization Suggestions of Typical Dust Collectors in Coal-Fired Power Plants
title_full Operational Status Analysis and Optimization Suggestions of Typical Dust Collectors in Coal-Fired Power Plants
title_fullStr Operational Status Analysis and Optimization Suggestions of Typical Dust Collectors in Coal-Fired Power Plants
title_full_unstemmed Operational Status Analysis and Optimization Suggestions of Typical Dust Collectors in Coal-Fired Power Plants
title_short Operational Status Analysis and Optimization Suggestions of Typical Dust Collectors in Coal-Fired Power Plants
title_sort operational status analysis and optimization suggestions of typical dust collectors in coal fired power plants
topic coal-fired power plants
dust collectors
operation status
optimization for efficiency improvement
energy saving for efficiency improvement
url https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202205031
work_keys_str_mv AT zunqiangsun operationalstatusanalysisandoptimizationsuggestionsoftypicaldustcollectorsincoalfiredpowerplants
AT chenghangzheng operationalstatusanalysisandoptimizationsuggestionsoftypicaldustcollectorsincoalfiredpowerplants
AT canzhou operationalstatusanalysisandoptimizationsuggestionsoftypicaldustcollectorsincoalfiredpowerplants
AT shengwang operationalstatusanalysisandoptimizationsuggestionsoftypicaldustcollectorsincoalfiredpowerplants
AT xiuyuanma operationalstatusanalysisandoptimizationsuggestionsoftypicaldustcollectorsincoalfiredpowerplants
AT yikeye operationalstatusanalysisandoptimizationsuggestionsoftypicaldustcollectorsincoalfiredpowerplants