Survey on quality control of hemodialysis in Wuhan city in 2016

Objective To investigate and analyze the data of quality control of hemodialysis units in Wuhan city,and propose countermeasures. Methods The Hemodialysis Quality Control Center of Wuhan city carried out the annual investigation of 40 hemodialysis units,including the centralized endotoxin detection...

Full description

Saved in:
Bibliographic Details
Main Authors: XIONG Fei, MIN Yong-long, ZHANG Yan-min, HE Da, CHEN Fang
Format: Article
Language:zho
Published: Editorial Department of Journal of Clinical Nephrology 2017-01-01
Series:Linchuang shenzangbing zazhi
Subjects:
Online Access:http://www.lcszb.com/thesisDetails?columnId=57916828&Fpath=home&index=0
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849323488187252736
author XIONG Fei
MIN Yong-long
ZHANG Yan-min
HE Da
CHEN Fang
author_facet XIONG Fei
MIN Yong-long
ZHANG Yan-min
HE Da
CHEN Fang
author_sort XIONG Fei
collection DOAJ
description Objective To investigate and analyze the data of quality control of hemodialysis units in Wuhan city,and propose countermeasures. Methods The Hemodialysis Quality Control Center of Wuhan city carried out the annual investigation of 40 hemodialysis units,including the centralized endotoxin detection of dialysis water in each hemodialysis unit. Simultaneously,the dialysis quality data of each dialysis unit were collected and analyzed,including vascular access,hemoglobin( Hb),serum albumin( Alb),serum calcium( Ca),phosphorus( P) and parathyroid hormone( PTH),etc. Results Among the 40 hemodialysis units,endotoxin detection in 4 samples reached a set standard in 26 units( 65%),and the rest units exceeded the standard to varying degrees. All units reached the set standard after rectification. The overall catheter ratio was 22. 22%,and 93. 9% of units exceeded the standard. The reaching standard rate of Hb,Alb,Ca,P and iP TH was 54. 69%,81. 08%,65. 24%,41. 17% and 47. 52%,and the average values of them were( 98. 77 ± 5. 91) g/L,( 37. 47 ± 7. 12) g/L,( 2. 22 ± 0. 09) mmol/L,( 1. 77 ± 0. 52) mmol/L,and( 299. 8 ± 156. 43) ng/L respectively. Conclusions The overall level of hemodialysis in Wuhan was similar to that of domestic level,and the quality control of hemodialysis units should be strengthened to further improve the level of hemodialysis in Wuhan.
format Article
id doaj-art-660bddc01d8e4e34b9506a950f5cf36d
institution Kabale University
issn 1671-2390
language zho
publishDate 2017-01-01
publisher Editorial Department of Journal of Clinical Nephrology
record_format Article
series Linchuang shenzangbing zazhi
spelling doaj-art-660bddc01d8e4e34b9506a950f5cf36d2025-08-20T03:49:02ZzhoEditorial Department of Journal of Clinical NephrologyLinchuang shenzangbing zazhi1671-23902017-01-0146146557916828Survey on quality control of hemodialysis in Wuhan city in 2016XIONG FeiMIN Yong-longZHANG Yan-minHE DaCHEN FangObjective To investigate and analyze the data of quality control of hemodialysis units in Wuhan city,and propose countermeasures. Methods The Hemodialysis Quality Control Center of Wuhan city carried out the annual investigation of 40 hemodialysis units,including the centralized endotoxin detection of dialysis water in each hemodialysis unit. Simultaneously,the dialysis quality data of each dialysis unit were collected and analyzed,including vascular access,hemoglobin( Hb),serum albumin( Alb),serum calcium( Ca),phosphorus( P) and parathyroid hormone( PTH),etc. Results Among the 40 hemodialysis units,endotoxin detection in 4 samples reached a set standard in 26 units( 65%),and the rest units exceeded the standard to varying degrees. All units reached the set standard after rectification. The overall catheter ratio was 22. 22%,and 93. 9% of units exceeded the standard. The reaching standard rate of Hb,Alb,Ca,P and iP TH was 54. 69%,81. 08%,65. 24%,41. 17% and 47. 52%,and the average values of them were( 98. 77 ± 5. 91) g/L,( 37. 47 ± 7. 12) g/L,( 2. 22 ± 0. 09) mmol/L,( 1. 77 ± 0. 52) mmol/L,and( 299. 8 ± 156. 43) ng/L respectively. Conclusions The overall level of hemodialysis in Wuhan was similar to that of domestic level,and the quality control of hemodialysis units should be strengthened to further improve the level of hemodialysis in Wuhan.http://www.lcszb.com/thesisDetails?columnId=57916828&Fpath=home&index=0HemodialysisQuality controlEndotoxinCatheter
spellingShingle XIONG Fei
MIN Yong-long
ZHANG Yan-min
HE Da
CHEN Fang
Survey on quality control of hemodialysis in Wuhan city in 2016
Linchuang shenzangbing zazhi
Hemodialysis
Quality control
Endotoxin
Catheter
title Survey on quality control of hemodialysis in Wuhan city in 2016
title_full Survey on quality control of hemodialysis in Wuhan city in 2016
title_fullStr Survey on quality control of hemodialysis in Wuhan city in 2016
title_full_unstemmed Survey on quality control of hemodialysis in Wuhan city in 2016
title_short Survey on quality control of hemodialysis in Wuhan city in 2016
title_sort survey on quality control of hemodialysis in wuhan city in 2016
topic Hemodialysis
Quality control
Endotoxin
Catheter
url http://www.lcszb.com/thesisDetails?columnId=57916828&Fpath=home&index=0
work_keys_str_mv AT xiongfei surveyonqualitycontrolofhemodialysisinwuhancityin2016
AT minyonglong surveyonqualitycontrolofhemodialysisinwuhancityin2016
AT zhangyanmin surveyonqualitycontrolofhemodialysisinwuhancityin2016
AT heda surveyonqualitycontrolofhemodialysisinwuhancityin2016
AT chenfang surveyonqualitycontrolofhemodialysisinwuhancityin2016