Optimization of dual duct forced auxiliary ventilation system to mitigate particulate matter emissions in a polymetallic underground mine environment: A hybrid approach.
The auxiliary ventilation system (AVS) is essential for managing airflow and reducing particulate matter (PM) levels in underground mine environments. Despite its importance, prior studies have insufficiently examined the optimal design of dual duct forced (DDF) AVS to improve airflow and PM managem...
Saved in:
| Main Authors: | Abdullah Rasheed Qureshi, Sergei Sabanov, Emil Bayramov, Jessica Neafie |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Public Library of Science (PLoS)
2025-01-01
|
| Series: | PLoS ONE |
| Online Access: | https://doi.org/10.1371/journal.pone.0322278 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
Sustainable development reduces particulate matter emissions and mitigates aging’s cognitive impact
by: Guiming Zhu, et al.
Published: (2025-05-01) -
Harnessing Electrostatic Forces: A Review of Bees as Bioindicators for Particulate Matter Detection
by: Simone Meacci, et al.
Published: (2025-04-01) -
Quantitative assessment of urban surface deformation risks from tectonic and seismic activities using multitemporal microwave satellite remote sensing: a case study of Almaty city and its surroundings in Kazakhstan
by: Emil Bayramov, et al.
Published: (2024-12-01) -
Quantifying particulate matter emission rates from naturally ventilated dairy buildings by considering roof opening contributions
by: Yujian Lu, et al.
Published: (2024-12-01) -
FEATURES OF THE CALCULATION OF VENTILATION DUCTS OF COMPLEX METAL FORM
by: M. V. Kaminets, et al.
Published: (2016-08-01)