Decoupled level and flow rate control of a two-tank system in beverage production: A comparative analysis of Fuzzy-PID and GA-PID for minimum time operation.

Due to the nonlinear characteristics of the valves and the interactions between the controlled variables, designing a control system for coupled tanks is a difficult task. This paper deals with the comparative study between Fuzzy-PID and GA-PID controllers for decoupling level and flow rate control...

Full description

Saved in:
Bibliographic Details
Main Authors: Tamiru Demelash Kassie, Mebratu Sintie Geremew, Kassahun Ashagrie Chanie
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2025-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0317600
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1823861028856791040
author Tamiru Demelash Kassie
Mebratu Sintie Geremew
Kassahun Ashagrie Chanie
author_facet Tamiru Demelash Kassie
Mebratu Sintie Geremew
Kassahun Ashagrie Chanie
author_sort Tamiru Demelash Kassie
collection DOAJ
description Due to the nonlinear characteristics of the valves and the interactions between the controlled variables, designing a control system for coupled tanks is a difficult task. This paper deals with the comparative study between Fuzzy-PID and GA-PID controllers for decoupling level and flow rate control of two tank systems for beverage factories with minimum time optimal operation. In most process control industries, each process requires multiple control variables. Here two input two output (TITO) systems are considered highly interacting multivariable control systems. The decoupling control scheme (Pre-compensator (dynamic) decoupling) is used to reduce the correlation between the controlled and manipulated variables by diagonalizing the system. The two independent SISO systems are further controlled by different controllers so that the system can trace the set point and yield a good time response. Two radically different control approaches are presented and compared for this system's dynamics, motivated by a desire to provide precise liquid-level control and regulate the flow rate. MATLAB /Simulink model and tuning algorithm (GA) are used for simulation. As the simulation result ensured, the GA-PID controller is the used for the specified system which is based on the transient and steady-state specifications. Quantitatively; the GA-PID controller has 39.167ms rise time, 8.50sec settling time, and -0.393% overshoot; whereas FLC-PID has 118.101ms rise time, 8.65sec settling time, and -0.033% overshoot. But in GA with PID controllers, the external disturbance tolerance capability of the proposed scheme, meaning robustness against external disturbance has a slight difference and FLC-PID has perfectly achieved the robustness. Depending on the result, FLC-PID has more result than GA-PID controller based on the set of specifications. Hence robustness is more important than time performances.
format Article
id doaj-art-64a4698dec5a4b8a9137143092c552f1
institution Kabale University
issn 1932-6203
language English
publishDate 2025-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj-art-64a4698dec5a4b8a9137143092c552f12025-02-10T05:30:35ZengPublic Library of Science (PLoS)PLoS ONE1932-62032025-01-01202e031760010.1371/journal.pone.0317600Decoupled level and flow rate control of a two-tank system in beverage production: A comparative analysis of Fuzzy-PID and GA-PID for minimum time operation.Tamiru Demelash KassieMebratu Sintie GeremewKassahun Ashagrie ChanieDue to the nonlinear characteristics of the valves and the interactions between the controlled variables, designing a control system for coupled tanks is a difficult task. This paper deals with the comparative study between Fuzzy-PID and GA-PID controllers for decoupling level and flow rate control of two tank systems for beverage factories with minimum time optimal operation. In most process control industries, each process requires multiple control variables. Here two input two output (TITO) systems are considered highly interacting multivariable control systems. The decoupling control scheme (Pre-compensator (dynamic) decoupling) is used to reduce the correlation between the controlled and manipulated variables by diagonalizing the system. The two independent SISO systems are further controlled by different controllers so that the system can trace the set point and yield a good time response. Two radically different control approaches are presented and compared for this system's dynamics, motivated by a desire to provide precise liquid-level control and regulate the flow rate. MATLAB /Simulink model and tuning algorithm (GA) are used for simulation. As the simulation result ensured, the GA-PID controller is the used for the specified system which is based on the transient and steady-state specifications. Quantitatively; the GA-PID controller has 39.167ms rise time, 8.50sec settling time, and -0.393% overshoot; whereas FLC-PID has 118.101ms rise time, 8.65sec settling time, and -0.033% overshoot. But in GA with PID controllers, the external disturbance tolerance capability of the proposed scheme, meaning robustness against external disturbance has a slight difference and FLC-PID has perfectly achieved the robustness. Depending on the result, FLC-PID has more result than GA-PID controller based on the set of specifications. Hence robustness is more important than time performances.https://doi.org/10.1371/journal.pone.0317600
spellingShingle Tamiru Demelash Kassie
Mebratu Sintie Geremew
Kassahun Ashagrie Chanie
Decoupled level and flow rate control of a two-tank system in beverage production: A comparative analysis of Fuzzy-PID and GA-PID for minimum time operation.
PLoS ONE
title Decoupled level and flow rate control of a two-tank system in beverage production: A comparative analysis of Fuzzy-PID and GA-PID for minimum time operation.
title_full Decoupled level and flow rate control of a two-tank system in beverage production: A comparative analysis of Fuzzy-PID and GA-PID for minimum time operation.
title_fullStr Decoupled level and flow rate control of a two-tank system in beverage production: A comparative analysis of Fuzzy-PID and GA-PID for minimum time operation.
title_full_unstemmed Decoupled level and flow rate control of a two-tank system in beverage production: A comparative analysis of Fuzzy-PID and GA-PID for minimum time operation.
title_short Decoupled level and flow rate control of a two-tank system in beverage production: A comparative analysis of Fuzzy-PID and GA-PID for minimum time operation.
title_sort decoupled level and flow rate control of a two tank system in beverage production a comparative analysis of fuzzy pid and ga pid for minimum time operation
url https://doi.org/10.1371/journal.pone.0317600
work_keys_str_mv AT tamirudemelashkassie decoupledlevelandflowratecontrolofatwotanksysteminbeverageproductionacomparativeanalysisoffuzzypidandgapidforminimumtimeoperation
AT mebratusintiegeremew decoupledlevelandflowratecontrolofatwotanksysteminbeverageproductionacomparativeanalysisoffuzzypidandgapidforminimumtimeoperation
AT kassahunashagriechanie decoupledlevelandflowratecontrolofatwotanksysteminbeverageproductionacomparativeanalysisoffuzzypidandgapidforminimumtimeoperation