Annual Energy Efficiency Analysis and Experiment Research on Variable Speed Air-Conditioner Based on Climatic Factors

Research on the annual performance factor specified in variable speed air-conditioner energy efficiency standard GB21455-2013. A variable speed air-conditioner was studied, two operating modes were established combining with typical meteorological year data. With the experiment and calculation, the...

Full description

Saved in:
Bibliographic Details
Main Authors: Li Tang, Wang Fang, Qu Yan, Meng Zhaofeng, Wang Yu, Zhao Yale, Guo Chao
Format: Article
Language:zho
Published: Journal of Refrigeration Magazines Agency Co., Ltd. 2015-01-01
Series:Zhileng xuebao
Subjects:
Online Access:http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2015.02.106
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849707755522228224
author Li Tang
Wang Fang
Qu Yan
Meng Zhaofeng
Wang Yu
Zhao Yale
Guo Chao
author_facet Li Tang
Wang Fang
Qu Yan
Meng Zhaofeng
Wang Yu
Zhao Yale
Guo Chao
author_sort Li Tang
collection DOAJ
description Research on the annual performance factor specified in variable speed air-conditioner energy efficiency standard GB21455-2013. A variable speed air-conditioner was studied, two operating modes were established combining with typical meteorological year data. With the experiment and calculation, the air conditioner SEER and HSPF in different cities and different modes were obtained. The running time cumulative rate of temperature range was introduced and relationships between SEER, HSPF and TAS were analyzed, the results show enhancing the air conditioner energy efficiency should focus on improving the different temperature range segment. The APF of each city, each mode and standard GB/T7725-2004 and GB21455-2013 were calculated, the relationships between SEER, HSPF and APF were analyzed. The results show cooling and heating temperature occurrence time specified in the standard do not fully reflect the actually APF of variable speed air-conditioner running at different regions of China and enhancing APF must focus on improving the HSPF.
format Article
id doaj-art-644d8993ca1c46e882f03a6d5f2c38a2
institution DOAJ
issn 0253-4339
language zho
publishDate 2015-01-01
publisher Journal of Refrigeration Magazines Agency Co., Ltd.
record_format Article
series Zhileng xuebao
spelling doaj-art-644d8993ca1c46e882f03a6d5f2c38a22025-08-20T03:15:51ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392015-01-013666516527Annual Energy Efficiency Analysis and Experiment Research on Variable Speed Air-Conditioner Based on Climatic FactorsLi TangWang FangQu YanMeng ZhaofengWang YuZhao YaleGuo ChaoResearch on the annual performance factor specified in variable speed air-conditioner energy efficiency standard GB21455-2013. A variable speed air-conditioner was studied, two operating modes were established combining with typical meteorological year data. With the experiment and calculation, the air conditioner SEER and HSPF in different cities and different modes were obtained. The running time cumulative rate of temperature range was introduced and relationships between SEER, HSPF and TAS were analyzed, the results show enhancing the air conditioner energy efficiency should focus on improving the different temperature range segment. The APF of each city, each mode and standard GB/T7725-2004 and GB21455-2013 were calculated, the relationships between SEER, HSPF and APF were analyzed. The results show cooling and heating temperature occurrence time specified in the standard do not fully reflect the actually APF of variable speed air-conditioner running at different regions of China and enhancing APF must focus on improving the HSPF.http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2015.02.106variable speed air-conditionerSEERAPFclimatic factorsoperating characteristics
spellingShingle Li Tang
Wang Fang
Qu Yan
Meng Zhaofeng
Wang Yu
Zhao Yale
Guo Chao
Annual Energy Efficiency Analysis and Experiment Research on Variable Speed Air-Conditioner Based on Climatic Factors
Zhileng xuebao
variable speed air-conditioner
SEER
APF
climatic factors
operating characteristics
title Annual Energy Efficiency Analysis and Experiment Research on Variable Speed Air-Conditioner Based on Climatic Factors
title_full Annual Energy Efficiency Analysis and Experiment Research on Variable Speed Air-Conditioner Based on Climatic Factors
title_fullStr Annual Energy Efficiency Analysis and Experiment Research on Variable Speed Air-Conditioner Based on Climatic Factors
title_full_unstemmed Annual Energy Efficiency Analysis and Experiment Research on Variable Speed Air-Conditioner Based on Climatic Factors
title_short Annual Energy Efficiency Analysis and Experiment Research on Variable Speed Air-Conditioner Based on Climatic Factors
title_sort annual energy efficiency analysis and experiment research on variable speed air conditioner based on climatic factors
topic variable speed air-conditioner
SEER
APF
climatic factors
operating characteristics
url http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2015.02.106
work_keys_str_mv AT litang annualenergyefficiencyanalysisandexperimentresearchonvariablespeedairconditionerbasedonclimaticfactors
AT wangfang annualenergyefficiencyanalysisandexperimentresearchonvariablespeedairconditionerbasedonclimaticfactors
AT quyan annualenergyefficiencyanalysisandexperimentresearchonvariablespeedairconditionerbasedonclimaticfactors
AT mengzhaofeng annualenergyefficiencyanalysisandexperimentresearchonvariablespeedairconditionerbasedonclimaticfactors
AT wangyu annualenergyefficiencyanalysisandexperimentresearchonvariablespeedairconditionerbasedonclimaticfactors
AT zhaoyale annualenergyefficiencyanalysisandexperimentresearchonvariablespeedairconditionerbasedonclimaticfactors
AT guochao annualenergyefficiencyanalysisandexperimentresearchonvariablespeedairconditionerbasedonclimaticfactors