Baseline values for Quantra® QPlus® in healthy pregnant women at term and comparison to standard laboratory coagulation values: a prospective observational study

Abstract Background Hypofibrinogenemia is associated with progression from moderate to severe postpartum hemorrhage (PPH). Early recognition and replacement of fibrinogen are emphasized during the management of PPH. The Quantra® QPlus® System, a novel point-of-care viscoelastic testing (POCVT) devic...

Full description

Saved in:
Bibliographic Details
Main Authors: Suthawan Anakmeteeprugsa, Antonio Gonzalez-Fiol, Angelique Garay, Hung-Mo Lin, Zili He, Aymen Alian
Format: Article
Language:English
Published: BMC 2025-08-01
Series:BMC Pregnancy and Childbirth
Subjects:
Online Access:https://doi.org/10.1186/s12884-025-07927-z
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849738693167808512
author Suthawan Anakmeteeprugsa
Antonio Gonzalez-Fiol
Angelique Garay
Hung-Mo Lin
Zili He
Aymen Alian
author_facet Suthawan Anakmeteeprugsa
Antonio Gonzalez-Fiol
Angelique Garay
Hung-Mo Lin
Zili He
Aymen Alian
author_sort Suthawan Anakmeteeprugsa
collection DOAJ
description Abstract Background Hypofibrinogenemia is associated with progression from moderate to severe postpartum hemorrhage (PPH). Early recognition and replacement of fibrinogen are emphasized during the management of PPH. The Quantra® QPlus® System, a novel point-of-care viscoelastic testing (POCVT) device, has been designed to provide rapid assessment of hemostasis. We aimed to evaluate the correlation between Quantra parameters and standard laboratory coagulation tests, and to establish baseline Quantra values in healthy term pregnant women. Methods Healthy pregnant women in labor or scheduled for elective cesarean delivery (CD) were enrolled in our prospective observational study. Blood samples for Quantra and standard laboratory coagulation tests were taken simultaneously. Quantra values, standard laboratory coagulation test, time of blood collected, and time to the result were recorded. We compared the baseline values between CD and labor group using a t-test, and the correlation between Quantra and standard laboratory coagulation test was calculated using partial Pearson correlation. Results 170 healthy pregnant women were included; 126 cases were in the CD group, and 44 patients were in the labor group. We found a strong correlation between Quantra Fibrinogen contribution to Clot Stiffness (FCS) and fibrinogen level (r = 0.67). The median [interquartile range] time of fibrinogen results by Quantra was 36 [28, 48] minutes faster than the standard laboratory coagulation tests. Baseline ranges for Quantra values, which were not significantly different between the two groups, demonstrated hyperfibrinogenemia during pregnancy. Conclusion Quantra is a novel POCVT device that rapidly provides coagulation status in pregnant women. The strong correlation between FCS and fibrinogen level can be helpful for early recognition of hypofibrinogenemia for the management of PPH.
format Article
id doaj-art-63cf51edd1e04a5d92ace3d5a4fb1d6b
institution DOAJ
issn 1471-2393
language English
publishDate 2025-08-01
publisher BMC
record_format Article
series BMC Pregnancy and Childbirth
spelling doaj-art-63cf51edd1e04a5d92ace3d5a4fb1d6b2025-08-20T03:06:29ZengBMCBMC Pregnancy and Childbirth1471-23932025-08-012511810.1186/s12884-025-07927-zBaseline values for Quantra® QPlus® in healthy pregnant women at term and comparison to standard laboratory coagulation values: a prospective observational studySuthawan Anakmeteeprugsa0Antonio Gonzalez-Fiol1Angelique Garay2Hung-Mo Lin3Zili He4Aymen Alian5Department of Anesthesiology, Yale University School of MedicineDepartment of Anesthesiology, Yale University School of MedicineDepartment of Anesthesiology, Yale University School of MedicineDepartment of Anesthesiology, Yale University School of MedicineYale Center for Analytical Sciences, Yale University School of Public HealthDepartment of Anesthesiology, Yale University School of MedicineAbstract Background Hypofibrinogenemia is associated with progression from moderate to severe postpartum hemorrhage (PPH). Early recognition and replacement of fibrinogen are emphasized during the management of PPH. The Quantra® QPlus® System, a novel point-of-care viscoelastic testing (POCVT) device, has been designed to provide rapid assessment of hemostasis. We aimed to evaluate the correlation between Quantra parameters and standard laboratory coagulation tests, and to establish baseline Quantra values in healthy term pregnant women. Methods Healthy pregnant women in labor or scheduled for elective cesarean delivery (CD) were enrolled in our prospective observational study. Blood samples for Quantra and standard laboratory coagulation tests were taken simultaneously. Quantra values, standard laboratory coagulation test, time of blood collected, and time to the result were recorded. We compared the baseline values between CD and labor group using a t-test, and the correlation between Quantra and standard laboratory coagulation test was calculated using partial Pearson correlation. Results 170 healthy pregnant women were included; 126 cases were in the CD group, and 44 patients were in the labor group. We found a strong correlation between Quantra Fibrinogen contribution to Clot Stiffness (FCS) and fibrinogen level (r = 0.67). The median [interquartile range] time of fibrinogen results by Quantra was 36 [28, 48] minutes faster than the standard laboratory coagulation tests. Baseline ranges for Quantra values, which were not significantly different between the two groups, demonstrated hyperfibrinogenemia during pregnancy. Conclusion Quantra is a novel POCVT device that rapidly provides coagulation status in pregnant women. The strong correlation between FCS and fibrinogen level can be helpful for early recognition of hypofibrinogenemia for the management of PPH.https://doi.org/10.1186/s12884-025-07927-zBlood coagulation testHypofibrinogenemiaPoint-of-care viscoelastic testingPostpartum hemorrhage
spellingShingle Suthawan Anakmeteeprugsa
Antonio Gonzalez-Fiol
Angelique Garay
Hung-Mo Lin
Zili He
Aymen Alian
Baseline values for Quantra® QPlus® in healthy pregnant women at term and comparison to standard laboratory coagulation values: a prospective observational study
BMC Pregnancy and Childbirth
Blood coagulation test
Hypofibrinogenemia
Point-of-care viscoelastic testing
Postpartum hemorrhage
title Baseline values for Quantra® QPlus® in healthy pregnant women at term and comparison to standard laboratory coagulation values: a prospective observational study
title_full Baseline values for Quantra® QPlus® in healthy pregnant women at term and comparison to standard laboratory coagulation values: a prospective observational study
title_fullStr Baseline values for Quantra® QPlus® in healthy pregnant women at term and comparison to standard laboratory coagulation values: a prospective observational study
title_full_unstemmed Baseline values for Quantra® QPlus® in healthy pregnant women at term and comparison to standard laboratory coagulation values: a prospective observational study
title_short Baseline values for Quantra® QPlus® in healthy pregnant women at term and comparison to standard laboratory coagulation values: a prospective observational study
title_sort baseline values for quantra r qplus r in healthy pregnant women at term and comparison to standard laboratory coagulation values a prospective observational study
topic Blood coagulation test
Hypofibrinogenemia
Point-of-care viscoelastic testing
Postpartum hemorrhage
url https://doi.org/10.1186/s12884-025-07927-z
work_keys_str_mv AT suthawananakmeteeprugsa baselinevaluesforquantraqplusinhealthypregnantwomenattermandcomparisontostandardlaboratorycoagulationvaluesaprospectiveobservationalstudy
AT antoniogonzalezfiol baselinevaluesforquantraqplusinhealthypregnantwomenattermandcomparisontostandardlaboratorycoagulationvaluesaprospectiveobservationalstudy
AT angeliquegaray baselinevaluesforquantraqplusinhealthypregnantwomenattermandcomparisontostandardlaboratorycoagulationvaluesaprospectiveobservationalstudy
AT hungmolin baselinevaluesforquantraqplusinhealthypregnantwomenattermandcomparisontostandardlaboratorycoagulationvaluesaprospectiveobservationalstudy
AT zilihe baselinevaluesforquantraqplusinhealthypregnantwomenattermandcomparisontostandardlaboratorycoagulationvaluesaprospectiveobservationalstudy
AT aymenalian baselinevaluesforquantraqplusinhealthypregnantwomenattermandcomparisontostandardlaboratorycoagulationvaluesaprospectiveobservationalstudy