Effects of Defrost-Initiation Criteria and Orientations of an Outdoor Heat Exchanger on the Performance of an Automotive Reversible CO<sub>2</sub> Heat Pump
Heat pump (HP) technology has been widely adopted in electric vehicles (EVs) for cabin and battery heating in cold weather due to its high efficiency. However, when an HP works under low ambient temperatures and high humidity, frost grows on the surface of the outdoor evaporator, deteriorating syste...
Saved in:
| Main Authors: | , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
MDPI AG
2025-04-01
|
| Series: | Energies |
| Subjects: | |
| Online Access: | https://www.mdpi.com/1996-1073/18/9/2244 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850155811402153984 |
|---|---|
| author | Wenying Zhang Wenzhe Li Pega Hrnjak |
| author_facet | Wenying Zhang Wenzhe Li Pega Hrnjak |
| author_sort | Wenying Zhang |
| collection | DOAJ |
| description | Heat pump (HP) technology has been widely adopted in electric vehicles (EVs) for cabin and battery heating in cold weather due to its high efficiency. However, when an HP works under low ambient temperatures and high humidity, frost grows on the surface of the outdoor evaporator, deteriorating system efficiency. This study experimentally investigated the performance of an automotive reversible CO<sub>2</sub> HP system under cyclic frosting–defrosting conditions, with different defrost-initiation criteria and orientations of the outdoor heat exchanger. The relationship between the performance degradation of the heat pump system and the feature of frost accumulation on the outdoor heat exchanger is analyzed. The experimental data revealed that the heating capacity of the HP system only mildly degrades (~30%), even with an air-side pressure drop of the outdoor heat exchanger growing 10 times, which enables the system to work in HP mode for a longer time before the defrosting without significantly impacting passengers’ comfort. The horizontally installed outdoor heat exchanger is proven to have better refrigerant distribution, but with approximately a 0.16 bar (11.9%) higher pressure drop, reducing the evaporating temperature by about 0.4 K. Consequently, frost accumulates faster, and the working time in HP mode is shortened by 12 min (18.2%). Moreover, the vertical outdoor heat exchanger drains much more water during the defrosting. As a result, the defrosting time for the vertical outdoor heat exchanger is reduced by 17%. |
| format | Article |
| id | doaj-art-626d0b7f3b564d40bc015285a15a5678 |
| institution | OA Journals |
| issn | 1996-1073 |
| language | English |
| publishDate | 2025-04-01 |
| publisher | MDPI AG |
| record_format | Article |
| series | Energies |
| spelling | doaj-art-626d0b7f3b564d40bc015285a15a56782025-08-20T02:24:46ZengMDPI AGEnergies1996-10732025-04-01189224410.3390/en18092244Effects of Defrost-Initiation Criteria and Orientations of an Outdoor Heat Exchanger on the Performance of an Automotive Reversible CO<sub>2</sub> Heat PumpWenying Zhang0Wenzhe Li1Pega Hrnjak2Air Conditioning and Refrigeration Center (ACRC), Department of Mechanical Science and Engineering, University of Illinois Urbana Champaign, Urbana, IL 61801, USASchool of Energy Science and Engineering, Central South University, Changsha 410083, ChinaAir Conditioning and Refrigeration Center (ACRC), Department of Mechanical Science and Engineering, University of Illinois Urbana Champaign, Urbana, IL 61801, USAHeat pump (HP) technology has been widely adopted in electric vehicles (EVs) for cabin and battery heating in cold weather due to its high efficiency. However, when an HP works under low ambient temperatures and high humidity, frost grows on the surface of the outdoor evaporator, deteriorating system efficiency. This study experimentally investigated the performance of an automotive reversible CO<sub>2</sub> HP system under cyclic frosting–defrosting conditions, with different defrost-initiation criteria and orientations of the outdoor heat exchanger. The relationship between the performance degradation of the heat pump system and the feature of frost accumulation on the outdoor heat exchanger is analyzed. The experimental data revealed that the heating capacity of the HP system only mildly degrades (~30%), even with an air-side pressure drop of the outdoor heat exchanger growing 10 times, which enables the system to work in HP mode for a longer time before the defrosting without significantly impacting passengers’ comfort. The horizontally installed outdoor heat exchanger is proven to have better refrigerant distribution, but with approximately a 0.16 bar (11.9%) higher pressure drop, reducing the evaporating temperature by about 0.4 K. Consequently, frost accumulates faster, and the working time in HP mode is shortened by 12 min (18.2%). Moreover, the vertical outdoor heat exchanger drains much more water during the defrosting. As a result, the defrosting time for the vertical outdoor heat exchanger is reduced by 17%.https://www.mdpi.com/1996-1073/18/9/2244automotive heat pumpCO<sub>2</sub>frosting and defrostingdefrost-initiation criteriaoutdoor heat exchanger orientation |
| spellingShingle | Wenying Zhang Wenzhe Li Pega Hrnjak Effects of Defrost-Initiation Criteria and Orientations of an Outdoor Heat Exchanger on the Performance of an Automotive Reversible CO<sub>2</sub> Heat Pump Energies automotive heat pump CO<sub>2</sub> frosting and defrosting defrost-initiation criteria outdoor heat exchanger orientation |
| title | Effects of Defrost-Initiation Criteria and Orientations of an Outdoor Heat Exchanger on the Performance of an Automotive Reversible CO<sub>2</sub> Heat Pump |
| title_full | Effects of Defrost-Initiation Criteria and Orientations of an Outdoor Heat Exchanger on the Performance of an Automotive Reversible CO<sub>2</sub> Heat Pump |
| title_fullStr | Effects of Defrost-Initiation Criteria and Orientations of an Outdoor Heat Exchanger on the Performance of an Automotive Reversible CO<sub>2</sub> Heat Pump |
| title_full_unstemmed | Effects of Defrost-Initiation Criteria and Orientations of an Outdoor Heat Exchanger on the Performance of an Automotive Reversible CO<sub>2</sub> Heat Pump |
| title_short | Effects of Defrost-Initiation Criteria and Orientations of an Outdoor Heat Exchanger on the Performance of an Automotive Reversible CO<sub>2</sub> Heat Pump |
| title_sort | effects of defrost initiation criteria and orientations of an outdoor heat exchanger on the performance of an automotive reversible co sub 2 sub heat pump |
| topic | automotive heat pump CO<sub>2</sub> frosting and defrosting defrost-initiation criteria outdoor heat exchanger orientation |
| url | https://www.mdpi.com/1996-1073/18/9/2244 |
| work_keys_str_mv | AT wenyingzhang effectsofdefrostinitiationcriteriaandorientationsofanoutdoorheatexchangerontheperformanceofanautomotivereversiblecosub2subheatpump AT wenzheli effectsofdefrostinitiationcriteriaandorientationsofanoutdoorheatexchangerontheperformanceofanautomotivereversiblecosub2subheatpump AT pegahrnjak effectsofdefrostinitiationcriteriaandorientationsofanoutdoorheatexchangerontheperformanceofanautomotivereversiblecosub2subheatpump |