Measurement and Characteristic Analysis of Electromagnetic Disturbance of Coal Mine Fan Converter

With the extensive use of converters in high-power ventilator, shearer, road header, conveyor, hoist, and other coal mine equipment, the electromagnetic disturbance problem of the converter is worthy of attention. In this paper, the field measurement and statistical method are used to analyze the ra...

Full description

Saved in:
Bibliographic Details
Main Authors: Zhonghua Xin, Xiaodong Zhang, Shuqian Yu, Huijuan Wang, Xiaoqian Jia, Yuling Ma
Format: Article
Language:English
Published: Wiley 2021-01-01
Series:International Journal of Antennas and Propagation
Online Access:http://dx.doi.org/10.1155/2021/5509562
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849410917208424448
author Zhonghua Xin
Xiaodong Zhang
Shuqian Yu
Huijuan Wang
Xiaoqian Jia
Yuling Ma
author_facet Zhonghua Xin
Xiaodong Zhang
Shuqian Yu
Huijuan Wang
Xiaoqian Jia
Yuling Ma
author_sort Zhonghua Xin
collection DOAJ
description With the extensive use of converters in high-power ventilator, shearer, road header, conveyor, hoist, and other coal mine equipment, the electromagnetic disturbance problem of the converter is worthy of attention. In this paper, the field measurement and statistical method are used to analyze the radiation interference characteristics of frequency converter. Then, a typical fan converter is taken as an example, and the electromagnetic disturbance of the converter is tested in four key positions and two working frequencies, respectively. Multiple sets of data and spectrum are obtained by using a spectrum analyzer and other instruments, and the dominant frequency characteristic parameters of the converter are analyzed emphatically. The small sample data adopts the Shapiro–Wilk test, and the 80%/80% rule was used for statistical analysis. Finally, we got five common frequencies of electromagnetic interference generated by the converter (electric field dBμV/m). The CH4 sensor and other sensors work near these five dominant frequencies, which may affect the normal operation of the sensor and cause alarm. The test and analysis method proposed in this paper can be used to obtain the characteristic parameters of the converter electromagnetic disturbance, which can be used as a reference for the design of the immunity of sensors or control instruments.
format Article
id doaj-art-610eb5a2671a4527a0dcfa6a22b7bb71
institution Kabale University
issn 1687-5869
1687-5877
language English
publishDate 2021-01-01
publisher Wiley
record_format Article
series International Journal of Antennas and Propagation
spelling doaj-art-610eb5a2671a4527a0dcfa6a22b7bb712025-08-20T03:34:56ZengWileyInternational Journal of Antennas and Propagation1687-58691687-58772021-01-01202110.1155/2021/55095625509562Measurement and Characteristic Analysis of Electromagnetic Disturbance of Coal Mine Fan ConverterZhonghua Xin0Xiaodong Zhang1Shuqian Yu2Huijuan Wang3Xiaoqian Jia4Yuling Ma5School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, ChinaSchool of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, ChinaSchool of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, ChinaSchool of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, ChinaSchool of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, ChinaCangzhou Jiaotong College, Huanghua, Hebei 061199, ChinaWith the extensive use of converters in high-power ventilator, shearer, road header, conveyor, hoist, and other coal mine equipment, the electromagnetic disturbance problem of the converter is worthy of attention. In this paper, the field measurement and statistical method are used to analyze the radiation interference characteristics of frequency converter. Then, a typical fan converter is taken as an example, and the electromagnetic disturbance of the converter is tested in four key positions and two working frequencies, respectively. Multiple sets of data and spectrum are obtained by using a spectrum analyzer and other instruments, and the dominant frequency characteristic parameters of the converter are analyzed emphatically. The small sample data adopts the Shapiro–Wilk test, and the 80%/80% rule was used for statistical analysis. Finally, we got five common frequencies of electromagnetic interference generated by the converter (electric field dBμV/m). The CH4 sensor and other sensors work near these five dominant frequencies, which may affect the normal operation of the sensor and cause alarm. The test and analysis method proposed in this paper can be used to obtain the characteristic parameters of the converter electromagnetic disturbance, which can be used as a reference for the design of the immunity of sensors or control instruments.http://dx.doi.org/10.1155/2021/5509562
spellingShingle Zhonghua Xin
Xiaodong Zhang
Shuqian Yu
Huijuan Wang
Xiaoqian Jia
Yuling Ma
Measurement and Characteristic Analysis of Electromagnetic Disturbance of Coal Mine Fan Converter
International Journal of Antennas and Propagation
title Measurement and Characteristic Analysis of Electromagnetic Disturbance of Coal Mine Fan Converter
title_full Measurement and Characteristic Analysis of Electromagnetic Disturbance of Coal Mine Fan Converter
title_fullStr Measurement and Characteristic Analysis of Electromagnetic Disturbance of Coal Mine Fan Converter
title_full_unstemmed Measurement and Characteristic Analysis of Electromagnetic Disturbance of Coal Mine Fan Converter
title_short Measurement and Characteristic Analysis of Electromagnetic Disturbance of Coal Mine Fan Converter
title_sort measurement and characteristic analysis of electromagnetic disturbance of coal mine fan converter
url http://dx.doi.org/10.1155/2021/5509562
work_keys_str_mv AT zhonghuaxin measurementandcharacteristicanalysisofelectromagneticdisturbanceofcoalminefanconverter
AT xiaodongzhang measurementandcharacteristicanalysisofelectromagneticdisturbanceofcoalminefanconverter
AT shuqianyu measurementandcharacteristicanalysisofelectromagneticdisturbanceofcoalminefanconverter
AT huijuanwang measurementandcharacteristicanalysisofelectromagneticdisturbanceofcoalminefanconverter
AT xiaoqianjia measurementandcharacteristicanalysisofelectromagneticdisturbanceofcoalminefanconverter
AT yulingma measurementandcharacteristicanalysisofelectromagneticdisturbanceofcoalminefanconverter