INTEGRATING INDOOR THERMAL COMFORT OPPORTUNITIES FROM TRADITIONAL BUILDING TYPES INTO THE DELIVERY AND MANAGEMENT OF SUSTAINABLE BUILT ENVIRONMENTS

Amid the different contemporary strategies for the delivery and management of sustainable development in the African context, not much emphasis has been placed on seeking for the existence or otherwise, of thermal opportunities from the inherent building types of our forebears. This paper therefore...

Full description

Saved in:
Bibliographic Details
Main Author: Marcellinus Uwadiegwu OKAFOR
Format: Article
Language:English
Published: UJ Press 2018-06-01
Series:Journal of Construction Project Management and Innovation
Subjects:
Online Access:https://journals.uj.ac.za/index.php/JCPMI/article/view/150
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841555166960025600
author Marcellinus Uwadiegwu OKAFOR
author_facet Marcellinus Uwadiegwu OKAFOR
author_sort Marcellinus Uwadiegwu OKAFOR
collection DOAJ
description Amid the different contemporary strategies for the delivery and management of sustainable development in the African context, not much emphasis has been placed on seeking for the existence or otherwise, of thermal opportunities from the inherent building types of our forebears. This paper therefore, through case study design approach, reported the developmental trend of indoor thermal comfort opportunities of building types with the design and construction traits representing the historic eras of pre-colonial, colonial and contemporary in Okigwe, Nigeria. The primary data were got from field observations made for 366 days (1 November 2015 – 31 October 2016) on the indoor and outdoor temperature and relative humidity values using Tinytag Explorer 4.9 Germini data loggers and secondary data from the nearest Meteorological Station, Imo State International Cargo Airport, Owerri, Nigeria. The mean annual outdoor temperature and relative humidity values were 29.00C and 69.9% respectively. Analyses of the results using one-way ANOVA test for differences were statistically significant; indoor air temperature [F (2, 1095) = 77.56, p = 0.0001] and relative humidity [F (2, 1095) = 5.76, p = 0.0001]. Further interrogation using the Tukey’s HSD (Honest Significant Difference) post-hoc comparison test amongst the building types revealed that indoor air temperature (27.830C) and relative humidity (71%) of pre-colonial building type were significantly different from those of colonial (28.430C and 67.39%) and contemporary building types (29.270C and 66.75%). The paper recommended that the valid traditional practices as expressed in the pre-colonial building types be re-integrated into the delivery and management of sustainable development in Nigeria. Thus, it concluded that opportunities abound in the indoor thermal comfort traceable to the traditional building (pre-colonial) types of our forebears as they performed thermally better than colonial and contemporary building types.
format Article
id doaj-art-600e63f756e04b0fa3e4ac7995b2a754
institution Kabale University
issn 2223-7852
2959-9652
language English
publishDate 2018-06-01
publisher UJ Press
record_format Article
series Journal of Construction Project Management and Innovation
spelling doaj-art-600e63f756e04b0fa3e4ac7995b2a7542025-01-08T06:11:33ZengUJ PressJournal of Construction Project Management and Innovation2223-78522959-96522018-06-018110.36615/jcpmi.v8i1.150INTEGRATING INDOOR THERMAL COMFORT OPPORTUNITIES FROM TRADITIONAL BUILDING TYPES INTO THE DELIVERY AND MANAGEMENT OF SUSTAINABLE BUILT ENVIRONMENTSMarcellinus Uwadiegwu OKAFOR0Department of Architecture, Imo State University, Owerri, Nigeria Amid the different contemporary strategies for the delivery and management of sustainable development in the African context, not much emphasis has been placed on seeking for the existence or otherwise, of thermal opportunities from the inherent building types of our forebears. This paper therefore, through case study design approach, reported the developmental trend of indoor thermal comfort opportunities of building types with the design and construction traits representing the historic eras of pre-colonial, colonial and contemporary in Okigwe, Nigeria. The primary data were got from field observations made for 366 days (1 November 2015 – 31 October 2016) on the indoor and outdoor temperature and relative humidity values using Tinytag Explorer 4.9 Germini data loggers and secondary data from the nearest Meteorological Station, Imo State International Cargo Airport, Owerri, Nigeria. The mean annual outdoor temperature and relative humidity values were 29.00C and 69.9% respectively. Analyses of the results using one-way ANOVA test for differences were statistically significant; indoor air temperature [F (2, 1095) = 77.56, p = 0.0001] and relative humidity [F (2, 1095) = 5.76, p = 0.0001]. Further interrogation using the Tukey’s HSD (Honest Significant Difference) post-hoc comparison test amongst the building types revealed that indoor air temperature (27.830C) and relative humidity (71%) of pre-colonial building type were significantly different from those of colonial (28.430C and 67.39%) and contemporary building types (29.270C and 66.75%). The paper recommended that the valid traditional practices as expressed in the pre-colonial building types be re-integrated into the delivery and management of sustainable development in Nigeria. Thus, it concluded that opportunities abound in the indoor thermal comfort traceable to the traditional building (pre-colonial) types of our forebears as they performed thermally better than colonial and contemporary building types. https://journals.uj.ac.za/index.php/JCPMI/article/view/150Contemporary building, Indoor thermal comfort, Okigwe-Nigeria, Sustainable development and Traditional building
spellingShingle Marcellinus Uwadiegwu OKAFOR
INTEGRATING INDOOR THERMAL COMFORT OPPORTUNITIES FROM TRADITIONAL BUILDING TYPES INTO THE DELIVERY AND MANAGEMENT OF SUSTAINABLE BUILT ENVIRONMENTS
Journal of Construction Project Management and Innovation
Contemporary building, Indoor thermal comfort, Okigwe-Nigeria, Sustainable development and Traditional building
title INTEGRATING INDOOR THERMAL COMFORT OPPORTUNITIES FROM TRADITIONAL BUILDING TYPES INTO THE DELIVERY AND MANAGEMENT OF SUSTAINABLE BUILT ENVIRONMENTS
title_full INTEGRATING INDOOR THERMAL COMFORT OPPORTUNITIES FROM TRADITIONAL BUILDING TYPES INTO THE DELIVERY AND MANAGEMENT OF SUSTAINABLE BUILT ENVIRONMENTS
title_fullStr INTEGRATING INDOOR THERMAL COMFORT OPPORTUNITIES FROM TRADITIONAL BUILDING TYPES INTO THE DELIVERY AND MANAGEMENT OF SUSTAINABLE BUILT ENVIRONMENTS
title_full_unstemmed INTEGRATING INDOOR THERMAL COMFORT OPPORTUNITIES FROM TRADITIONAL BUILDING TYPES INTO THE DELIVERY AND MANAGEMENT OF SUSTAINABLE BUILT ENVIRONMENTS
title_short INTEGRATING INDOOR THERMAL COMFORT OPPORTUNITIES FROM TRADITIONAL BUILDING TYPES INTO THE DELIVERY AND MANAGEMENT OF SUSTAINABLE BUILT ENVIRONMENTS
title_sort integrating indoor thermal comfort opportunities from traditional building types into the delivery and management of sustainable built environments
topic Contemporary building, Indoor thermal comfort, Okigwe-Nigeria, Sustainable development and Traditional building
url https://journals.uj.ac.za/index.php/JCPMI/article/view/150
work_keys_str_mv AT marcellinusuwadiegwuokafor integratingindoorthermalcomfortopportunitiesfromtraditionalbuildingtypesintothedeliveryandmanagementofsustainablebuiltenvironments