Impact of Large Number of Same Aggregated Distributed Generators on the High-Frequency Oscillatory Stability of a DC Microgrids

The construction of DC micro-grid is conducive to the nearby absorption of renewable energy. Meanwhile, the increase of power electronic devices in the micro-grid may lead to the occurrence of high-frequency oscillations and other phenomena, which requires the evaluation of the stability of small di...

Full description

Saved in:
Bibliographic Details
Main Authors: Tianyi ZHANG, Kaiyuan ZHENG, Haifeng WANG
Format: Article
Language:zho
Published: State Grid Energy Research Institute 2021-08-01
Series:Zhongguo dianli
Subjects:
Online Access:https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202105196
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850051640315346944
author Tianyi ZHANG
Kaiyuan ZHENG
Haifeng WANG
author_facet Tianyi ZHANG
Kaiyuan ZHENG
Haifeng WANG
author_sort Tianyi ZHANG
collection DOAJ
description The construction of DC micro-grid is conducive to the nearby absorption of renewable energy. Meanwhile, the increase of power electronic devices in the micro-grid may lead to the occurrence of high-frequency oscillations and other phenomena, which requires the evaluation of the stability of small disturbances during planning. In the evaluation process, the number of micro-power source is approximately proportional to the dimension of the system state matrix, so a large number of micro-power source connections bring challenges to modal calculation. It is necessary to propose a method of order reduction to meet the requirements of small disturbance stability analysis of DC microgrid. The aggregated reduced order model for high frequency oscillations can reduce the workload of numerical calculation in the process of modal analysis of microgrids, which is helpful for better evaluation of microgrids in the planning stage. In the last part, simulations are carried out to verify the method for different micropower access quantity and different microgrid topology. The simulation results show that the method proposed in this paper can effectively evaluate the high frequency oscillation risk of DC micro-grid and simplify the difficulty of calculation.
format Article
id doaj-art-5fe292c16dbc43e3810683e287909eba
institution DOAJ
issn 1004-9649
language zho
publishDate 2021-08-01
publisher State Grid Energy Research Institute
record_format Article
series Zhongguo dianli
spelling doaj-art-5fe292c16dbc43e3810683e287909eba2025-08-20T02:53:03ZzhoState Grid Energy Research InstituteZhongguo dianli1004-96492021-08-0154810310810.11930/j.issn.1004-9649.202105196zgdl-54-7-zhangtianyiImpact of Large Number of Same Aggregated Distributed Generators on the High-Frequency Oscillatory Stability of a DC MicrogridsTianyi ZHANG0Kaiyuan ZHENG1Haifeng WANG2State Key Laboratory for Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, ChinaState Key Laboratory for Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, ChinaState Key Laboratory for Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, ChinaThe construction of DC micro-grid is conducive to the nearby absorption of renewable energy. Meanwhile, the increase of power electronic devices in the micro-grid may lead to the occurrence of high-frequency oscillations and other phenomena, which requires the evaluation of the stability of small disturbances during planning. In the evaluation process, the number of micro-power source is approximately proportional to the dimension of the system state matrix, so a large number of micro-power source connections bring challenges to modal calculation. It is necessary to propose a method of order reduction to meet the requirements of small disturbance stability analysis of DC microgrid. The aggregated reduced order model for high frequency oscillations can reduce the workload of numerical calculation in the process of modal analysis of microgrids, which is helpful for better evaluation of microgrids in the planning stage. In the last part, simulations are carried out to verify the method for different micropower access quantity and different microgrid topology. The simulation results show that the method proposed in this paper can effectively evaluate the high frequency oscillation risk of DC micro-grid and simplify the difficulty of calculation.https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202105196multi-microsource small signal stabilityreduced-order modal computationdc microgridhigh-frequency oscillatory
spellingShingle Tianyi ZHANG
Kaiyuan ZHENG
Haifeng WANG
Impact of Large Number of Same Aggregated Distributed Generators on the High-Frequency Oscillatory Stability of a DC Microgrids
Zhongguo dianli
multi-microsource small signal stability
reduced-order modal computation
dc microgrid
high-frequency oscillatory
title Impact of Large Number of Same Aggregated Distributed Generators on the High-Frequency Oscillatory Stability of a DC Microgrids
title_full Impact of Large Number of Same Aggregated Distributed Generators on the High-Frequency Oscillatory Stability of a DC Microgrids
title_fullStr Impact of Large Number of Same Aggregated Distributed Generators on the High-Frequency Oscillatory Stability of a DC Microgrids
title_full_unstemmed Impact of Large Number of Same Aggregated Distributed Generators on the High-Frequency Oscillatory Stability of a DC Microgrids
title_short Impact of Large Number of Same Aggregated Distributed Generators on the High-Frequency Oscillatory Stability of a DC Microgrids
title_sort impact of large number of same aggregated distributed generators on the high frequency oscillatory stability of a dc microgrids
topic multi-microsource small signal stability
reduced-order modal computation
dc microgrid
high-frequency oscillatory
url https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202105196
work_keys_str_mv AT tianyizhang impactoflargenumberofsameaggregateddistributedgeneratorsonthehighfrequencyoscillatorystabilityofadcmicrogrids
AT kaiyuanzheng impactoflargenumberofsameaggregateddistributedgeneratorsonthehighfrequencyoscillatorystabilityofadcmicrogrids
AT haifengwang impactoflargenumberofsameaggregateddistributedgeneratorsonthehighfrequencyoscillatorystabilityofadcmicrogrids