Experimental Investigation on the Concentric and Nonconcentric Waste Heat Recovery Device

A series of tests were carried out on a new structure of heat pipe exchanger. It uses acetone as working fluid. The investigation was conducted at different heat loads, the tilt angles of device are 30°、45°、60°、75°、90°and the charging ratio of working fluid is 30%. The angles, length and operation t...

Full description

Saved in:
Bibliographic Details
Main Authors: Zhang Zhenglai, Han Xiaoxing, Wang Yaxiong, WuWei, Li Penghui
Format: Article
Language:zho
Published: Journal of Refrigeration Magazines Agency Co., Ltd. 2016-01-01
Series:Zhileng xuebao
Subjects:
Online Access:http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2016.03.048
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A series of tests were carried out on a new structure of heat pipe exchanger. It uses acetone as working fluid. The investigation was conducted at different heat loads, the tilt angles of device are 30°、45°、60°、75°、90°and the charging ratio of working fluid is 30%. The angles, length and operation temperature was adjusted in the test to investigate the thermal performance and effectiveness of heat recovery system. It reveals that the maximum heat transport increases with the augment of the operation temperature, evaporation length. Eventually, the experimental data showed that the optimum operating angle is 60°with evaporation length of 270 mm.
ISSN:0253-4339