Development of a High-Frequency Ophthalmic Real-Time Ultrasound Imaging System Based on a 20 MHz Annular-Array Transducer

Objective. Ophthalmic ultrasound imaging is a widely used diagnostic method for examining ophthalmic diseases in the clinic. A single-element transducer is adopted in the traditional ophthalmic ultrasound imaging systems. Although full depth focusing can be achieved using a linear-array transducer,...

Full description

Saved in:
Bibliographic Details
Main Authors: Xiaochun Wang, Zemeng Li, Sheng Zhou
Format: Article
Language:English
Published: Wiley 2024-01-01
Series:Journal of Engineering
Online Access:http://dx.doi.org/10.1155/2024/5378806
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849220829908303872
author Xiaochun Wang
Zemeng Li
Sheng Zhou
author_facet Xiaochun Wang
Zemeng Li
Sheng Zhou
author_sort Xiaochun Wang
collection DOAJ
description Objective. Ophthalmic ultrasound imaging is a widely used diagnostic method for examining ophthalmic diseases in the clinic. A single-element transducer is adopted in the traditional ophthalmic ultrasound imaging systems. Although full depth focusing can be achieved using a linear-array transducer, it is unsuitable for ophthalmic imaging due to its inability to be tightly coupled to the eyeball and its higher cost. Annular-array-based systems provide an alternative, striking a balance between image quality and cost. Methods. Here, we present a newly developed high-frequency ophthalmic real-time ultrasound imaging system based on an annular-array transducer. This system uses a custom-made five-element, 20 MHz annular-array transducer encapsulated in a stainless steel housing and mounted in a commercially available handheld mechanical probe designed specifically for clinical ophthalmic imaging. The system uses a printed circuit board scheme and FPGA as the core to complete the hardware system design and realize the ultrasonic echo signal processing and system timing management. Full depth dynamic focusing of each scanning beam was achieved by designing the transmit and receive beamforming. Combined with advanced integrated circuits, the miniaturization and low cost of the overall system are realized. Results. Extensive tests, including hardware, wire phantom, and tissue mimicking phantom measurements, were conducted to demonstrate good performance of the system. The results showed that the designed system can effectively improve the imaging resolution and enhance the depth of field of the image, particularly reducing the blind area of the near-field. Conclusion. The high-frequency ophthalmic real-time ultrasound imaging system based on an annular-array transducer meets the needs of clinical diagnosis and has a good clinical application prospect.
format Article
id doaj-art-5ef7b5f2e902497a8f3bebdbe36fe382
institution Kabale University
issn 2314-4912
language English
publishDate 2024-01-01
publisher Wiley
record_format Article
series Journal of Engineering
spelling doaj-art-5ef7b5f2e902497a8f3bebdbe36fe3822024-12-02T08:53:52ZengWileyJournal of Engineering2314-49122024-01-01202410.1155/2024/5378806Development of a High-Frequency Ophthalmic Real-Time Ultrasound Imaging System Based on a 20 MHz Annular-Array TransducerXiaochun Wang0Zemeng Li1Sheng Zhou2Institute of Biomedical EngineeringInstitute of Biomedical EngineeringInstitute of Biomedical EngineeringObjective. Ophthalmic ultrasound imaging is a widely used diagnostic method for examining ophthalmic diseases in the clinic. A single-element transducer is adopted in the traditional ophthalmic ultrasound imaging systems. Although full depth focusing can be achieved using a linear-array transducer, it is unsuitable for ophthalmic imaging due to its inability to be tightly coupled to the eyeball and its higher cost. Annular-array-based systems provide an alternative, striking a balance between image quality and cost. Methods. Here, we present a newly developed high-frequency ophthalmic real-time ultrasound imaging system based on an annular-array transducer. This system uses a custom-made five-element, 20 MHz annular-array transducer encapsulated in a stainless steel housing and mounted in a commercially available handheld mechanical probe designed specifically for clinical ophthalmic imaging. The system uses a printed circuit board scheme and FPGA as the core to complete the hardware system design and realize the ultrasonic echo signal processing and system timing management. Full depth dynamic focusing of each scanning beam was achieved by designing the transmit and receive beamforming. Combined with advanced integrated circuits, the miniaturization and low cost of the overall system are realized. Results. Extensive tests, including hardware, wire phantom, and tissue mimicking phantom measurements, were conducted to demonstrate good performance of the system. The results showed that the designed system can effectively improve the imaging resolution and enhance the depth of field of the image, particularly reducing the blind area of the near-field. Conclusion. The high-frequency ophthalmic real-time ultrasound imaging system based on an annular-array transducer meets the needs of clinical diagnosis and has a good clinical application prospect.http://dx.doi.org/10.1155/2024/5378806
spellingShingle Xiaochun Wang
Zemeng Li
Sheng Zhou
Development of a High-Frequency Ophthalmic Real-Time Ultrasound Imaging System Based on a 20 MHz Annular-Array Transducer
Journal of Engineering
title Development of a High-Frequency Ophthalmic Real-Time Ultrasound Imaging System Based on a 20 MHz Annular-Array Transducer
title_full Development of a High-Frequency Ophthalmic Real-Time Ultrasound Imaging System Based on a 20 MHz Annular-Array Transducer
title_fullStr Development of a High-Frequency Ophthalmic Real-Time Ultrasound Imaging System Based on a 20 MHz Annular-Array Transducer
title_full_unstemmed Development of a High-Frequency Ophthalmic Real-Time Ultrasound Imaging System Based on a 20 MHz Annular-Array Transducer
title_short Development of a High-Frequency Ophthalmic Real-Time Ultrasound Imaging System Based on a 20 MHz Annular-Array Transducer
title_sort development of a high frequency ophthalmic real time ultrasound imaging system based on a 20 mhz annular array transducer
url http://dx.doi.org/10.1155/2024/5378806
work_keys_str_mv AT xiaochunwang developmentofahighfrequencyophthalmicrealtimeultrasoundimagingsystembasedona20mhzannulararraytransducer
AT zemengli developmentofahighfrequencyophthalmicrealtimeultrasoundimagingsystembasedona20mhzannulararraytransducer
AT shengzhou developmentofahighfrequencyophthalmicrealtimeultrasoundimagingsystembasedona20mhzannulararraytransducer