Double C-Loop Haptic Lenses Are Rotationally Stable – A Systematic Review

Sheraz Daya,1 Christophe Chassain,2 Christophe Pagnoulle3 1Centre for Sight, East Grinstead, West Sussex, UK; 2Clinique Beau Soleil, Montpellier, France; 3Research and Development Department, BVI, Liège, BelgiumCorrespondence: Christophe Pagnoulle, Research and Development Department, BVI.All. des N...

Full description

Saved in:
Bibliographic Details
Main Authors: Daya S, Chassain C, Pagnoulle C
Format: Article
Language:English
Published: Dove Medical Press 2025-07-01
Series:Clinical Ophthalmology
Subjects:
Online Access:https://www.dovepress.com/double-c-loop-haptic-lenses-are-rotationally-stable--a-systematic-revi-peer-reviewed-fulltext-article-OPTH
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849701639772962816
author Daya S
Chassain C
Pagnoulle C
author_facet Daya S
Chassain C
Pagnoulle C
author_sort Daya S
collection DOAJ
description Sheraz Daya,1 Christophe Chassain,2 Christophe Pagnoulle3 1Centre for Sight, East Grinstead, West Sussex, UK; 2Clinique Beau Soleil, Montpellier, France; 3Research and Development Department, BVI, Liège, BelgiumCorrespondence: Christophe Pagnoulle, Research and Development Department, BVI.All. des Noisetiers 4, Liège, 4031, Belgium, Email cpagnoulle@bvimedical.comAbstract: The purpose of this review is to summarize the clinical rotational stability outcomes reported in patients following implantation of the POD platform with double C-loop haptics. A literature search in PubMed (US National Library of Medicine) was carried out to find publications, both prospective and retrospective, which report rotational stability outcomes in patients who were implanted with this platform after cataract or refractive lens exchange surgeries. This platform is used in different commercially available intraocular lenses (IOLs), both monofocal and trifocal, made of hydrophilic or hydrophobic material. 19 clinical peer-reviewed studies published between 2013 and 2024 were included in this review. The data reported in the clinical publications was analyzed in detail, focusing on rotational stability (mean rotation values and ranges, and percentage of eyes with some degrees of rotation), measurement methods and rotation follow-up period. Our review encompassed a total of 1428 eyes implanted with the POD platform analyzed at different follow-up periods, up to a maximum of 26 months. The mean rotation across all the studies was 2.61 °.The analysis carried out in this review leads us to conclude that the POD platform provides good rotational stability when used with different IOL models based on monofocal or trifocal designs and made using hydrophilic or hydrophobic material.Keywords: rotational stability, haptic, double C-loop, intraocular lens, platform
format Article
id doaj-art-5e5e92b11e9f4a5c831aa4fa2057625b
institution DOAJ
issn 1177-5483
language English
publishDate 2025-07-01
publisher Dove Medical Press
record_format Article
series Clinical Ophthalmology
spelling doaj-art-5e5e92b11e9f4a5c831aa4fa2057625b2025-08-20T03:17:53ZengDove Medical PressClinical Ophthalmology1177-54832025-07-01Volume 19Issue 122592269104767Double C-Loop Haptic Lenses Are Rotationally Stable – A Systematic ReviewDaya S0Chassain CPagnoulle C1OphthalmologyResearch and DevelopmentSheraz Daya,1 Christophe Chassain,2 Christophe Pagnoulle3 1Centre for Sight, East Grinstead, West Sussex, UK; 2Clinique Beau Soleil, Montpellier, France; 3Research and Development Department, BVI, Liège, BelgiumCorrespondence: Christophe Pagnoulle, Research and Development Department, BVI.All. des Noisetiers 4, Liège, 4031, Belgium, Email cpagnoulle@bvimedical.comAbstract: The purpose of this review is to summarize the clinical rotational stability outcomes reported in patients following implantation of the POD platform with double C-loop haptics. A literature search in PubMed (US National Library of Medicine) was carried out to find publications, both prospective and retrospective, which report rotational stability outcomes in patients who were implanted with this platform after cataract or refractive lens exchange surgeries. This platform is used in different commercially available intraocular lenses (IOLs), both monofocal and trifocal, made of hydrophilic or hydrophobic material. 19 clinical peer-reviewed studies published between 2013 and 2024 were included in this review. The data reported in the clinical publications was analyzed in detail, focusing on rotational stability (mean rotation values and ranges, and percentage of eyes with some degrees of rotation), measurement methods and rotation follow-up period. Our review encompassed a total of 1428 eyes implanted with the POD platform analyzed at different follow-up periods, up to a maximum of 26 months. The mean rotation across all the studies was 2.61 °.The analysis carried out in this review leads us to conclude that the POD platform provides good rotational stability when used with different IOL models based on monofocal or trifocal designs and made using hydrophilic or hydrophobic material.Keywords: rotational stability, haptic, double C-loop, intraocular lens, platformhttps://www.dovepress.com/double-c-loop-haptic-lenses-are-rotationally-stable--a-systematic-revi-peer-reviewed-fulltext-article-OPTHrotational stabilityhapticdouble C-loopintraocular lensplatform
spellingShingle Daya S
Chassain C
Pagnoulle C
Double C-Loop Haptic Lenses Are Rotationally Stable – A Systematic Review
Clinical Ophthalmology
rotational stability
haptic
double C-loop
intraocular lens
platform
title Double C-Loop Haptic Lenses Are Rotationally Stable – A Systematic Review
title_full Double C-Loop Haptic Lenses Are Rotationally Stable – A Systematic Review
title_fullStr Double C-Loop Haptic Lenses Are Rotationally Stable – A Systematic Review
title_full_unstemmed Double C-Loop Haptic Lenses Are Rotationally Stable – A Systematic Review
title_short Double C-Loop Haptic Lenses Are Rotationally Stable – A Systematic Review
title_sort double c loop haptic lenses are rotationally stable amp ndash a systematic review
topic rotational stability
haptic
double C-loop
intraocular lens
platform
url https://www.dovepress.com/double-c-loop-haptic-lenses-are-rotationally-stable--a-systematic-revi-peer-reviewed-fulltext-article-OPTH
work_keys_str_mv AT dayas doublecloophapticlensesarerotationallystableampndashasystematicreview
AT chassainc doublecloophapticlensesarerotationallystableampndashasystematicreview
AT pagnoullec doublecloophapticlensesarerotationallystableampndashasystematicreview