Indoor Radon Concentration Measurements At Hebron University Campus :A Case Study
TASTRAK, a solid state nuclear track detector has been used to measure indoor radon concentrations at Hebron University. Fifty- four radon pot detectors were mounted in the four university buildings. It was found that the radon concentrations vary considerably from about 1 Bq/m 3 to 250 Bq/m3 The av...
Saved in:
| Main Author: | |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
An-Najah National University
1996-09-01
|
| Series: | مجلة جامعة النجاح للأبحاث العلوم الطبيعية |
| Online Access: | https://journals.najah.edu/media/journals/full_texts/indoor-radon-concentration-measurements-hebron-university-campus-case-study.pdf |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Summary: | TASTRAK, a solid state nuclear track detector has been used to measure indoor radon concentrations at Hebron University. Fifty- four radon pot detectors were mounted in the four university buildings. It was found that the radon concentrations vary considerably from about 1 Bq/m 3 to 250 Bq/m3 The average radon concentrations vary from 20.5 Bq/m3 in the Main Building to 41.3 Bq/m3 in the Agriculture Building. The average radon concentration in the four buildings is found to be 29.8 Bq/m 3. This leads to an average effective dose equivalent of 1.49 mSvly. This dose is slightly higher than the global value of 1.3 mSv/y. Elevated radon concentrations have been found in few rooms. However, these concentrations are well below the action level of 150 Bq/m3. |
|---|---|