Development of Resonant Density Meter and Its Application in Tailings Backfilling

To solve the problems of low measurement accuracy, poor safety, and stability of the traditional pipeline liquid density meter, a MIMR-XZ6 pipeline liquid density meter was designed based on the vibration mathematical model of fluid flowing through the pipeline. The pipeline liquid densitometer main...

Full description

Saved in:
Bibliographic Details
Main Author: Xiaozhou Cheng
Format: Article
Language:English
Published: Wiley 2021-01-01
Series:Advances in Civil Engineering
Online Access:http://dx.doi.org/10.1155/2021/1522639
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849411560438497280
author Xiaozhou Cheng
author_facet Xiaozhou Cheng
author_sort Xiaozhou Cheng
collection DOAJ
description To solve the problems of low measurement accuracy, poor safety, and stability of the traditional pipeline liquid density meter, a MIMR-XZ6 pipeline liquid density meter was designed based on the vibration mathematical model of fluid flowing through the pipeline. The pipeline liquid densitometer mainly consisted of a vibration tube for the liquid passing by, a distributed inductance encircled around the inner wall of the vibration tube, a resistor, and a capacitor, respectively, connected to both ends of the inductance, and the inductor, resistor, and capacitor formed the RLC series resonant circuit; an excitation signal source which could generate an alternating current (AC) voltage signal in different frequencies was applied to both ends of the RLC series resonant circuit, and the AC voltage signal was connected to the series branch formed by the inductance and the capacitor to capture the electrical signals. In view of the practical application of this liquid pipe densitometer in tailings backfilling, the installation method of the liquid pipe densitometer is flexible, and the slurry flows in a fluent and stable manner, meeting the measuring requirement of the resonant concentration analyzer. The MIMR-XZ6 pipeline liquid densitometer was used for online detection of ore pulp density, and the precision of this densitometer met the needs of industrial applications.
format Article
id doaj-art-5dd50e7066184ea1a5bb1cbcec04720b
institution Kabale University
issn 1687-8086
1687-8094
language English
publishDate 2021-01-01
publisher Wiley
record_format Article
series Advances in Civil Engineering
spelling doaj-art-5dd50e7066184ea1a5bb1cbcec04720b2025-08-20T03:34:44ZengWileyAdvances in Civil Engineering1687-80861687-80942021-01-01202110.1155/2021/15226391522639Development of Resonant Density Meter and Its Application in Tailings BackfillingXiaozhou Cheng0China University of Mining and Technology (Xuzhou), No. 1 Jinshan East Road, Quanshan District, Xuzhou City, Jiangsu 221008, ChinaTo solve the problems of low measurement accuracy, poor safety, and stability of the traditional pipeline liquid density meter, a MIMR-XZ6 pipeline liquid density meter was designed based on the vibration mathematical model of fluid flowing through the pipeline. The pipeline liquid densitometer mainly consisted of a vibration tube for the liquid passing by, a distributed inductance encircled around the inner wall of the vibration tube, a resistor, and a capacitor, respectively, connected to both ends of the inductance, and the inductor, resistor, and capacitor formed the RLC series resonant circuit; an excitation signal source which could generate an alternating current (AC) voltage signal in different frequencies was applied to both ends of the RLC series resonant circuit, and the AC voltage signal was connected to the series branch formed by the inductance and the capacitor to capture the electrical signals. In view of the practical application of this liquid pipe densitometer in tailings backfilling, the installation method of the liquid pipe densitometer is flexible, and the slurry flows in a fluent and stable manner, meeting the measuring requirement of the resonant concentration analyzer. The MIMR-XZ6 pipeline liquid densitometer was used for online detection of ore pulp density, and the precision of this densitometer met the needs of industrial applications.http://dx.doi.org/10.1155/2021/1522639
spellingShingle Xiaozhou Cheng
Development of Resonant Density Meter and Its Application in Tailings Backfilling
Advances in Civil Engineering
title Development of Resonant Density Meter and Its Application in Tailings Backfilling
title_full Development of Resonant Density Meter and Its Application in Tailings Backfilling
title_fullStr Development of Resonant Density Meter and Its Application in Tailings Backfilling
title_full_unstemmed Development of Resonant Density Meter and Its Application in Tailings Backfilling
title_short Development of Resonant Density Meter and Its Application in Tailings Backfilling
title_sort development of resonant density meter and its application in tailings backfilling
url http://dx.doi.org/10.1155/2021/1522639
work_keys_str_mv AT xiaozhoucheng developmentofresonantdensitymeteranditsapplicationintailingsbackfilling