Efek Penggunaan Water Mist Terhadap Tekanan, Temperatur dan Kinerja Sistem Mesin Pengkondisian Udara Tipe Terpisah

<p>The air conditioning machine commonly used is air conditioning system with a vapor compression cycle. The use of air conditioning machines consumes more electrical energy than other household appliances. In this study, the addition of the water mist method in evaporative cooling system with...

Full description

Saved in:
Bibliographic Details
Main Authors: Azridjal Aziz, Bungsu Herwanto, Rahmat Iman Mainil
Format: Article
Language:English
Published: Department of Mechanical Engineering, Faculty of Engineering, Universitas Andalas 2020-07-01
Series:Metal: Jurnal Sistem Mekanik dan Termal
Subjects:
Online Access:https://metal.ft.unand.ac.id/index.php/metal/article/view/100
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832575019229642752
author Azridjal Aziz
Bungsu Herwanto
Rahmat Iman Mainil
author_facet Azridjal Aziz
Bungsu Herwanto
Rahmat Iman Mainil
author_sort Azridjal Aziz
collection DOAJ
description <p>The air conditioning machine commonly used is air conditioning system with a vapor compression cycle. The use of air conditioning machines consumes more electrical energy than other household appliances. In this study, the addition of the water mist method in evaporative cooling system with variations of distance of 20 cm, 40 cm, 60 cm so that the energy consumption of split type AC (Air Conditioning) of machines is more efficient. The results showed that the pressure of the condenser using water mist was lower 48 Psig than the pressure of condenser with a cooling load of 2000 W, and lower by 34 Psig of the pressure of condenser without the cooling load. Meanwhile the temperature of the air entering the condenser (Tout) after using a water mist has lower temperature than without the water mist, therefore it can save electricity consumption in the compressor. The temperature of the lowest inlet air of the condenser reached at the use of water mist with a distance variation of 60 cm was 28 ℃. And the relative humidity (RH)  relatively decrease at the exit  of the condenser using water mist with distance variation of 60 cm length was 59.6%. The compressor power decreased lower using a 60 cm distance water mist of 0.52 kW compared to without using a water mist with a 2000 W load of 0.56 kW. So that COP using water mist higher about 5.24 than without a water mist of 4.72. The highest COP was obtained using water mist at a distance of 60 cm</p>
format Article
id doaj-art-5d44cee46c3744d1b7930c4e8b4c0928
institution Kabale University
issn 2598-1137
2597-4483
language English
publishDate 2020-07-01
publisher Department of Mechanical Engineering, Faculty of Engineering, Universitas Andalas
record_format Article
series Metal: Jurnal Sistem Mekanik dan Termal
spelling doaj-art-5d44cee46c3744d1b7930c4e8b4c09282025-02-01T10:20:38ZengDepartment of Mechanical Engineering, Faculty of Engineering, Universitas AndalasMetal: Jurnal Sistem Mekanik dan Termal2598-11372597-44832020-07-013210110810.25077/metal.3.2.101-108.201958Efek Penggunaan Water Mist Terhadap Tekanan, Temperatur dan Kinerja Sistem Mesin Pengkondisian Udara Tipe TerpisahAzridjal Aziz0Bungsu Herwanto1Rahmat Iman Mainil2Department of Mechanical Engineering, Universitas Riau, Pekanbaru, RiauUniversitas RiauUniversitas Riau<p>The air conditioning machine commonly used is air conditioning system with a vapor compression cycle. The use of air conditioning machines consumes more electrical energy than other household appliances. In this study, the addition of the water mist method in evaporative cooling system with variations of distance of 20 cm, 40 cm, 60 cm so that the energy consumption of split type AC (Air Conditioning) of machines is more efficient. The results showed that the pressure of the condenser using water mist was lower 48 Psig than the pressure of condenser with a cooling load of 2000 W, and lower by 34 Psig of the pressure of condenser without the cooling load. Meanwhile the temperature of the air entering the condenser (Tout) after using a water mist has lower temperature than without the water mist, therefore it can save electricity consumption in the compressor. The temperature of the lowest inlet air of the condenser reached at the use of water mist with a distance variation of 60 cm was 28 ℃. And the relative humidity (RH)  relatively decrease at the exit  of the condenser using water mist with distance variation of 60 cm length was 59.6%. The compressor power decreased lower using a 60 cm distance water mist of 0.52 kW compared to without using a water mist with a 2000 W load of 0.56 kW. So that COP using water mist higher about 5.24 than without a water mist of 4.72. The highest COP was obtained using water mist at a distance of 60 cm</p>https://metal.ft.unand.ac.id/index.php/metal/article/view/100air conditioning, water mist, evaporative cooling, vapor compression cycle
spellingShingle Azridjal Aziz
Bungsu Herwanto
Rahmat Iman Mainil
Efek Penggunaan Water Mist Terhadap Tekanan, Temperatur dan Kinerja Sistem Mesin Pengkondisian Udara Tipe Terpisah
Metal: Jurnal Sistem Mekanik dan Termal
air conditioning, water mist, evaporative cooling, vapor compression cycle
title Efek Penggunaan Water Mist Terhadap Tekanan, Temperatur dan Kinerja Sistem Mesin Pengkondisian Udara Tipe Terpisah
title_full Efek Penggunaan Water Mist Terhadap Tekanan, Temperatur dan Kinerja Sistem Mesin Pengkondisian Udara Tipe Terpisah
title_fullStr Efek Penggunaan Water Mist Terhadap Tekanan, Temperatur dan Kinerja Sistem Mesin Pengkondisian Udara Tipe Terpisah
title_full_unstemmed Efek Penggunaan Water Mist Terhadap Tekanan, Temperatur dan Kinerja Sistem Mesin Pengkondisian Udara Tipe Terpisah
title_short Efek Penggunaan Water Mist Terhadap Tekanan, Temperatur dan Kinerja Sistem Mesin Pengkondisian Udara Tipe Terpisah
title_sort efek penggunaan water mist terhadap tekanan temperatur dan kinerja sistem mesin pengkondisian udara tipe terpisah
topic air conditioning, water mist, evaporative cooling, vapor compression cycle
url https://metal.ft.unand.ac.id/index.php/metal/article/view/100
work_keys_str_mv AT azridjalaziz efekpenggunaanwatermistterhadaptekanantemperaturdankinerjasistemmesinpengkondisianudaratipeterpisah
AT bungsuherwanto efekpenggunaanwatermistterhadaptekanantemperaturdankinerjasistemmesinpengkondisianudaratipeterpisah
AT rahmatimanmainil efekpenggunaanwatermistterhadaptekanantemperaturdankinerjasistemmesinpengkondisianudaratipeterpisah