MANUFACTURE AND TESTING OF VIBRATION TEST SCHEMES FOR PIPING SYSTEMS

Piping system is the distribution of fluids through pipes. This is often in everyday life, an example is the water pipe in every house that is used to fulfill desires and in the industrial field pipes are often used to distribute petroleum fluids as well as offshore and onshore. Supports have a very...

Full description

Saved in:
Bibliographic Details
Main Authors: Ali Ali, Hendiawan Nugraha Aldi Saputra
Format: Article
Language:Indonesian
Published: Universitas Mercu Buana 2024-06-01
Series:Jurnal Teknik Mesin
Subjects:
Online Access:https://publikasi.mercubuana.ac.id/index.php/jtm/article/view/25377
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850283012227334144
author Ali Ali
Hendiawan Nugraha Aldi Saputra
author_facet Ali Ali
Hendiawan Nugraha Aldi Saputra
author_sort Ali Ali
collection DOAJ
description Piping system is the distribution of fluids through pipes. This is often in everyday life, an example is the water pipe in every house that is used to fulfill desires and in the industrial field pipes are often used to distribute petroleum fluids as well as offshore and onshore. Supports have a very important role to overcome the loads that occur at points that experience excessive loads caused by the weight of pipes and other devices. In general, dynamic failures in pipe systems are caused by resonance from the vibrations of the pipe stretch. Therefore, this research is intended to determine the effect of valve opening variation and pedestal distance variation on vibration in the pipe system so that it can be used for consideration in designing a piping system. This research uses an experimental approach starting with the preparation of a vibration test scheme and then testing using a vibration meter. The test data was processed and statistically analyzed so that it was found that at 100% valve opening, the largest value is at a pedestal distance of 180 cm with a flow rate of 2.8 m/s2 and the largest 50% valve opening is at the same pedestal distance of 180 cm with a flow rate of 2.3 m/s2. The farther the pedestal distance, the greater the vibration and deflection and the greater the flow discharge produced, the higher the vibration produced
format Article
id doaj-art-5ca5361f75284a5f8d9cabbb0ee82f7d
institution OA Journals
issn 2089-7235
2549-2888
language Indonesian
publishDate 2024-06-01
publisher Universitas Mercu Buana
record_format Article
series Jurnal Teknik Mesin
spelling doaj-art-5ca5361f75284a5f8d9cabbb0ee82f7d2025-08-20T01:47:51ZindUniversitas Mercu BuanaJurnal Teknik Mesin2089-72352549-28882024-06-0113212412810.22441/jtm.v13i2.253777358MANUFACTURE AND TESTING OF VIBRATION TEST SCHEMES FOR PIPING SYSTEMSAli AliHendiawan Nugraha Aldi SaputraPiping system is the distribution of fluids through pipes. This is often in everyday life, an example is the water pipe in every house that is used to fulfill desires and in the industrial field pipes are often used to distribute petroleum fluids as well as offshore and onshore. Supports have a very important role to overcome the loads that occur at points that experience excessive loads caused by the weight of pipes and other devices. In general, dynamic failures in pipe systems are caused by resonance from the vibrations of the pipe stretch. Therefore, this research is intended to determine the effect of valve opening variation and pedestal distance variation on vibration in the pipe system so that it can be used for consideration in designing a piping system. This research uses an experimental approach starting with the preparation of a vibration test scheme and then testing using a vibration meter. The test data was processed and statistically analyzed so that it was found that at 100% valve opening, the largest value is at a pedestal distance of 180 cm with a flow rate of 2.8 m/s2 and the largest 50% valve opening is at the same pedestal distance of 180 cm with a flow rate of 2.3 m/s2. The farther the pedestal distance, the greater the vibration and deflection and the greater the flow discharge produced, the higher the vibration producedhttps://publikasi.mercubuana.ac.id/index.php/jtm/article/view/25377perpipaangetarankatuptumpuan
spellingShingle Ali Ali
Hendiawan Nugraha Aldi Saputra
MANUFACTURE AND TESTING OF VIBRATION TEST SCHEMES FOR PIPING SYSTEMS
Jurnal Teknik Mesin
perpipaan
getaran
katup
tumpuan
title MANUFACTURE AND TESTING OF VIBRATION TEST SCHEMES FOR PIPING SYSTEMS
title_full MANUFACTURE AND TESTING OF VIBRATION TEST SCHEMES FOR PIPING SYSTEMS
title_fullStr MANUFACTURE AND TESTING OF VIBRATION TEST SCHEMES FOR PIPING SYSTEMS
title_full_unstemmed MANUFACTURE AND TESTING OF VIBRATION TEST SCHEMES FOR PIPING SYSTEMS
title_short MANUFACTURE AND TESTING OF VIBRATION TEST SCHEMES FOR PIPING SYSTEMS
title_sort manufacture and testing of vibration test schemes for piping systems
topic perpipaan
getaran
katup
tumpuan
url https://publikasi.mercubuana.ac.id/index.php/jtm/article/view/25377
work_keys_str_mv AT aliali manufactureandtestingofvibrationtestschemesforpipingsystems
AT hendiawannugrahaaldisaputra manufactureandtestingofvibrationtestschemesforpipingsystems