Seismic Performance Evaluation of Precast Concrete Beam-to-Shear Link Composite Connection with Bending Moment and Shear Force Separate Method

A new type of prefabricated reinforced concrete-Y-shaped eccentrically steel brace structure (PRC-Y-ESBS) is developed by combining the mechanical property of prefabricated reinforced concrete frame and Y-shaped eccentrically steel brace, so the seismic performance and seismic resilience capacity of...

Full description

Saved in:
Bibliographic Details
Main Authors: Shujun Hu, Qi Guo, Xinfu Xiong, Jingang Xiong
Format: Article
Language:English
Published: Wiley 2020-01-01
Series:Advances in Civil Engineering
Online Access:http://dx.doi.org/10.1155/2020/9641906
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850226768135323648
author Shujun Hu
Qi Guo
Xinfu Xiong
Jingang Xiong
author_facet Shujun Hu
Qi Guo
Xinfu Xiong
Jingang Xiong
author_sort Shujun Hu
collection DOAJ
description A new type of prefabricated reinforced concrete-Y-shaped eccentrically steel brace structure (PRC-Y-ESBS) is developed by combining the mechanical property of prefabricated reinforced concrete frame and Y-shaped eccentrically steel brace, so the seismic performance and seismic resilience capacity of prefabricated reinforced concrete frame can be effectively improved. In the PRC-Y-ESBS, the precast concrete beam-to-shear link composite connection should have enough bearing capacity and resilience capacity under the shear force and bending moment, so the damage can be restricted in shear links. In this paper, an innovative precast concrete beam-to-shear link composite connection (PCB-SLCC) with bending moment and shear force separate method is proposed. Four different types of shear connectors are analyzed in detail by using the verified numerical method, and the shear capacity and failure mode of shear connectors can be obtained. Then, the innovative PCB-SLCCs with the reasonable shear connector considering different influencing parameters are also studied in detail. The results indicate that the shear connectors and high-strength bolts are still in elastic state at ultimate load, and little damage has occurred in the concrete between the embedded plate and precast concrete frame, while the PCB-SLCC has enough bearing capacity at the ultimate stage. In addition, this study also clearly identifies that high-strength bolts can only bear the bending moment, and the shear force is only carried by shear connectors, so the bending moment and shear force of the innovative PCB-SLCC with high bearing capacity, ease of installation, and seismic resilience capacity can be apparently separated.
format Article
id doaj-art-5c9ecfa038bb405d8a0a56863732bf9d
institution OA Journals
issn 1687-8086
1687-8094
language English
publishDate 2020-01-01
publisher Wiley
record_format Article
series Advances in Civil Engineering
spelling doaj-art-5c9ecfa038bb405d8a0a56863732bf9d2025-08-20T02:04:59ZengWileyAdvances in Civil Engineering1687-80861687-80942020-01-01202010.1155/2020/96419069641906Seismic Performance Evaluation of Precast Concrete Beam-to-Shear Link Composite Connection with Bending Moment and Shear Force Separate MethodShujun Hu0Qi Guo1Xinfu Xiong2Jingang Xiong3Zhongheng Construction Group Co. Ltd., Nanchang 330031, ChinaSchool of Civil Engineering and Architecture, Nanchang University, Nanchang 330031, ChinaZhongheng Construction Group Co. Ltd., Nanchang 330031, ChinaSchool of Civil Engineering and Architecture, Nanchang University, Nanchang 330031, ChinaA new type of prefabricated reinforced concrete-Y-shaped eccentrically steel brace structure (PRC-Y-ESBS) is developed by combining the mechanical property of prefabricated reinforced concrete frame and Y-shaped eccentrically steel brace, so the seismic performance and seismic resilience capacity of prefabricated reinforced concrete frame can be effectively improved. In the PRC-Y-ESBS, the precast concrete beam-to-shear link composite connection should have enough bearing capacity and resilience capacity under the shear force and bending moment, so the damage can be restricted in shear links. In this paper, an innovative precast concrete beam-to-shear link composite connection (PCB-SLCC) with bending moment and shear force separate method is proposed. Four different types of shear connectors are analyzed in detail by using the verified numerical method, and the shear capacity and failure mode of shear connectors can be obtained. Then, the innovative PCB-SLCCs with the reasonable shear connector considering different influencing parameters are also studied in detail. The results indicate that the shear connectors and high-strength bolts are still in elastic state at ultimate load, and little damage has occurred in the concrete between the embedded plate and precast concrete frame, while the PCB-SLCC has enough bearing capacity at the ultimate stage. In addition, this study also clearly identifies that high-strength bolts can only bear the bending moment, and the shear force is only carried by shear connectors, so the bending moment and shear force of the innovative PCB-SLCC with high bearing capacity, ease of installation, and seismic resilience capacity can be apparently separated.http://dx.doi.org/10.1155/2020/9641906
spellingShingle Shujun Hu
Qi Guo
Xinfu Xiong
Jingang Xiong
Seismic Performance Evaluation of Precast Concrete Beam-to-Shear Link Composite Connection with Bending Moment and Shear Force Separate Method
Advances in Civil Engineering
title Seismic Performance Evaluation of Precast Concrete Beam-to-Shear Link Composite Connection with Bending Moment and Shear Force Separate Method
title_full Seismic Performance Evaluation of Precast Concrete Beam-to-Shear Link Composite Connection with Bending Moment and Shear Force Separate Method
title_fullStr Seismic Performance Evaluation of Precast Concrete Beam-to-Shear Link Composite Connection with Bending Moment and Shear Force Separate Method
title_full_unstemmed Seismic Performance Evaluation of Precast Concrete Beam-to-Shear Link Composite Connection with Bending Moment and Shear Force Separate Method
title_short Seismic Performance Evaluation of Precast Concrete Beam-to-Shear Link Composite Connection with Bending Moment and Shear Force Separate Method
title_sort seismic performance evaluation of precast concrete beam to shear link composite connection with bending moment and shear force separate method
url http://dx.doi.org/10.1155/2020/9641906
work_keys_str_mv AT shujunhu seismicperformanceevaluationofprecastconcretebeamtoshearlinkcompositeconnectionwithbendingmomentandshearforceseparatemethod
AT qiguo seismicperformanceevaluationofprecastconcretebeamtoshearlinkcompositeconnectionwithbendingmomentandshearforceseparatemethod
AT xinfuxiong seismicperformanceevaluationofprecastconcretebeamtoshearlinkcompositeconnectionwithbendingmomentandshearforceseparatemethod
AT jingangxiong seismicperformanceevaluationofprecastconcretebeamtoshearlinkcompositeconnectionwithbendingmomentandshearforceseparatemethod