Comparative Evaluation of Denture Retention Using Three Border Moulding Techniques: A Non Randomised Clinical Study

Introduction: In complete dentures, the final impression plays a pivotal role in the success of the treatment. Advancements in impression materials have been the primary influence on the evolution of complete denture impression procedures. Aim: To compare and evaluate the retention of complete dent...

Full description

Saved in:
Bibliographic Details
Main Authors: Anne Mary, Deviprasad Nooji, Suhas K Rao
Format: Article
Language:English
Published: JCDR Research and Publications Private Limited 2024-11-01
Series:Journal of Clinical and Diagnostic Research
Subjects:
Online Access:https://www.jcdr.net/articles/PDF/20265/73972_CE[Ra1]__QC(AnK)_F(IS)_PF1(VD_SS)_PFA(VD_KM)_PN(KM).pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1846164227104964608
author Anne Mary
Deviprasad Nooji
Suhas K Rao
author_facet Anne Mary
Deviprasad Nooji
Suhas K Rao
author_sort Anne Mary
collection DOAJ
description Introduction: In complete dentures, the final impression plays a pivotal role in the success of the treatment. Advancements in impression materials have been the primary influence on the evolution of complete denture impression procedures. Aim: To compare and evaluate the retention of complete dentures fabricated on resorbed ridges using three different border moulding techniques. Materials and Methods: This non randomised clinical study was conducted in the Department of Prosthodontics and Crown and Bridge at KVG Dental College and Hospital, Sullia, Karnataka, India. The study included 10 patients with resorbed ridges who sought treatment from the Department of Prosthodontics during the period from January 2022 to December 2023. The study participants were selected from Dakshina Kannada and Kasargod, aged between 40 to 70 years, and included both males and females. For each patient, three custom trays were fabricated. The first tray was used for border moulding with putty and light body impression paste recorded using a Transcutaneous Electrical Stimulation (TENS) machine (Group A). The second tray was used for border moulding with putty and light body impression paste (Group B), while the third tray utilised a tissue conditioner as the secondary impression material (Group C). Retention was checked using a force gauge after the secondary impression, and heat-cured dentures were fabricated for each patient. The retention values were statistically analysed using Analysis of Variance (ANOVA), with the significance level set at p≤0.05. Results: The measurements indicated significantly higher mean retentive values in Group-A (2.58±0.56 kgf and 2.49±0.99 kgf for the secondary impression and final denture, respectively) compared to the other two groups (p<0.001). Comfort was reported to be better in Group-B. Both Groups A and B exhibited a good fit for the dentures. Conclusion: Within the limitations of the study, it can be inferred that border moulding with TENS using polyvinyl siloxane putty and light body secondary impressions provided higher retention compared to functional border moulding using tissue conditioner.
format Article
id doaj-art-5a87b817ffc64b61ab3a7977c95b1ef9
institution Kabale University
issn 2249-782X
0973-709X
language English
publishDate 2024-11-01
publisher JCDR Research and Publications Private Limited
record_format Article
series Journal of Clinical and Diagnostic Research
spelling doaj-art-5a87b817ffc64b61ab3a7977c95b1ef92024-11-18T11:53:22ZengJCDR Research and Publications Private LimitedJournal of Clinical and Diagnostic Research2249-782X0973-709X2024-11-011811404510.7860/JCDR/2024/73972.20265Comparative Evaluation of Denture Retention Using Three Border Moulding Techniques: A Non Randomised Clinical StudyAnne Mary0Deviprasad Nooji1Suhas K Rao2Postgraduate Resident, Department of Prosthodontics, KVG Dental College, Sullia, Karnataka, India.Professor, Department of Prosthodontics, KVG Dental College, Sullia, Karnataka, India.Professor and Head, Department of Prosthodontics, KVG Dental College, Sullia, Karnataka, India.Introduction: In complete dentures, the final impression plays a pivotal role in the success of the treatment. Advancements in impression materials have been the primary influence on the evolution of complete denture impression procedures. Aim: To compare and evaluate the retention of complete dentures fabricated on resorbed ridges using three different border moulding techniques. Materials and Methods: This non randomised clinical study was conducted in the Department of Prosthodontics and Crown and Bridge at KVG Dental College and Hospital, Sullia, Karnataka, India. The study included 10 patients with resorbed ridges who sought treatment from the Department of Prosthodontics during the period from January 2022 to December 2023. The study participants were selected from Dakshina Kannada and Kasargod, aged between 40 to 70 years, and included both males and females. For each patient, three custom trays were fabricated. The first tray was used for border moulding with putty and light body impression paste recorded using a Transcutaneous Electrical Stimulation (TENS) machine (Group A). The second tray was used for border moulding with putty and light body impression paste (Group B), while the third tray utilised a tissue conditioner as the secondary impression material (Group C). Retention was checked using a force gauge after the secondary impression, and heat-cured dentures were fabricated for each patient. The retention values were statistically analysed using Analysis of Variance (ANOVA), with the significance level set at p≤0.05. Results: The measurements indicated significantly higher mean retentive values in Group-A (2.58±0.56 kgf and 2.49±0.99 kgf for the secondary impression and final denture, respectively) compared to the other two groups (p<0.001). Comfort was reported to be better in Group-B. Both Groups A and B exhibited a good fit for the dentures. Conclusion: Within the limitations of the study, it can be inferred that border moulding with TENS using polyvinyl siloxane putty and light body secondary impressions provided higher retention compared to functional border moulding using tissue conditioner.https://www.jcdr.net/articles/PDF/20265/73972_CE[Ra1]__QC(AnK)_F(IS)_PF1(VD_SS)_PFA(VD_KM)_PN(KM).pdfdigital force gaugesecondary impressiontranscutaneous electrical stimulationtissue conditioner
spellingShingle Anne Mary
Deviprasad Nooji
Suhas K Rao
Comparative Evaluation of Denture Retention Using Three Border Moulding Techniques: A Non Randomised Clinical Study
Journal of Clinical and Diagnostic Research
digital force gauge
secondary impression
transcutaneous electrical stimulation
tissue conditioner
title Comparative Evaluation of Denture Retention Using Three Border Moulding Techniques: A Non Randomised Clinical Study
title_full Comparative Evaluation of Denture Retention Using Three Border Moulding Techniques: A Non Randomised Clinical Study
title_fullStr Comparative Evaluation of Denture Retention Using Three Border Moulding Techniques: A Non Randomised Clinical Study
title_full_unstemmed Comparative Evaluation of Denture Retention Using Three Border Moulding Techniques: A Non Randomised Clinical Study
title_short Comparative Evaluation of Denture Retention Using Three Border Moulding Techniques: A Non Randomised Clinical Study
title_sort comparative evaluation of denture retention using three border moulding techniques a non randomised clinical study
topic digital force gauge
secondary impression
transcutaneous electrical stimulation
tissue conditioner
url https://www.jcdr.net/articles/PDF/20265/73972_CE[Ra1]__QC(AnK)_F(IS)_PF1(VD_SS)_PFA(VD_KM)_PN(KM).pdf
work_keys_str_mv AT annemary comparativeevaluationofdentureretentionusingthreebordermouldingtechniquesanonrandomisedclinicalstudy
AT deviprasadnooji comparativeevaluationofdentureretentionusingthreebordermouldingtechniquesanonrandomisedclinicalstudy
AT suhaskrao comparativeevaluationofdentureretentionusingthreebordermouldingtechniquesanonrandomisedclinicalstudy