Treatment response evaluation using Yttrium-90 in patients with rheumatoid arthritis of knee joint

For radiosynovectomy, we have measured the retention time of yttrium-90 (90Y) hydroxyapatite (particle size 1–10 μm) within the knee joint space and evaluated the treatment responses in knees with rheumatoid arthritis. Radioactive measurements in the region of knee after injection of 90Y hydroxyapat...

Full description

Saved in:
Bibliographic Details
Main Authors: Jong Kim, Wi Kim, Yong Pak
Format: Article
Language:English
Published: Thieme Medical and Scientific Publishers Pvt. Ltd. 2018-01-01
Series:World Journal of Nuclear Medicine
Subjects:
Online Access:http://www.thieme-connect.de/DOI/DOI?10.4103/1450-1147.222289
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:For radiosynovectomy, we have measured the retention time of yttrium-90 (90Y) hydroxyapatite (particle size 1–10 μm) within the knee joint space and evaluated the treatment responses in knees with rheumatoid arthritis. Radioactive measurements in the region of knee after injection of 90Y hydroxyapatite into the joint space were made with a single prove system designed to monitor radioactivity and showed retention of 90Y in the knee ranged 76.6% ±5.4% after 4 days of injection. The clinical improvements in rheumatoid arthritis of knee joint with steinbroker Stages I and II were increased as time goes by, the improvement ratio is in 72% at 6th months and 76% at 12th months after injection of 90Y 185 MBq (5 mCi) per joint.
ISSN:1450-1147
1607-3312