The Validity of a Portable Strain-Gauge Apparatus Versus a Commercial Isokinetic Dynamometer for Evaluating Knee Extension Kinetics

# Background Isokinetic dynamometers are widely used when assessing neuromuscular function including knee extension kinetics. However, these dynamometers are often prohibitively expensive and are not portable. Thus strain-gauge technology has grown in popularity. # Purpose The purpose of this stu...

Full description

Saved in:
Bibliographic Details
Main Authors: Dustin Oranchuk, Chris Juneau, Shelley Diewald, Jono Neville, John Cronin
Format: Article
Language:English
Published: North American Sports Medicine Institute 2024-03-01
Series:International Journal of Sports Physical Therapy
Online Access:https://doi.org/10.26603/001c.92742
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1823857563547992064
author Dustin Oranchuk
Chris Juneau
Shelley Diewald
Jono Neville
John Cronin
author_facet Dustin Oranchuk
Chris Juneau
Shelley Diewald
Jono Neville
John Cronin
author_sort Dustin Oranchuk
collection DOAJ
description # Background Isokinetic dynamometers are widely used when assessing neuromuscular function including knee extension kinetics. However, these dynamometers are often prohibitively expensive and are not portable. Thus strain-gauge technology has grown in popularity. # Purpose The purpose of this study was to compare kinetic data captured via an isokinetic dynamometer against an affordable and portable strain-gauge with a treatment plinth during maximal isometric knee extensions. # Study Design Cross-sectional study. # Methods Healthy participants (8 males and 6 females; age 30.2±7.1 years) volunteered and performed knee extensions at a 90° knee angle on a dynamometer and a treatment plinth with a portable strain-gauge. Peak force (PF), peak rate of force development (PRFD), rate of force development (RFD~2080~) and impulse (IMP~2080~) from 20-80% of onset to peak force were assessed using both strain-gauge and isokinetic dynamometer. Between-device differences were evaluated by the Wilcoxon signed-rank test, Cohen's *d* effect sizes (ES), Pearson's correlation coefficients (*r*), and Bland-Altman plots. # Results No significant or meaningful differences were identified between isokinetic and strain-gauge devices (all *p*≥0.268, ES≤0.35). However, slightly greater (2.5-9.5%) outputs were observed with the isokinetic dynamometer. Very large significant between-device correlations were found for PF (*r*=0.77, *p*=0.001) and PRFD (*r*=0.73, *p*=0.003), while small and moderate non-significant between-device correlations were found for RFD~2080~ (*r*=0.48, *p*=0.079) and IMP~2080~ (*r*=0.59, *p*=0.060). Bland-Altman plots did not reveal apparent biases from high to low performers. # Conclusions These results indicate that the strain-gauge device can produce valid maximal and rapid force expression measurements. Similar results, such as those quantified via an isokinetic device, can be obtained without extreme rigour and constraint. The study's findings support using the practically relevant treatment plinth and strain-gauge combination as a suitable alternative to the isokinetic dynamometry for measuring PF and PRFD. Therefore, more rehabilitation and sports performance practitioners can confidently assess knee extension kinetics. # Level of Evidence 3
format Article
id doaj-art-5a23ff3ac1a44c7586f46974a75af0c3
institution Kabale University
issn 2159-2896
language English
publishDate 2024-03-01
publisher North American Sports Medicine Institute
record_format Article
series International Journal of Sports Physical Therapy
spelling doaj-art-5a23ff3ac1a44c7586f46974a75af0c32025-02-11T20:29:43ZengNorth American Sports Medicine InstituteInternational Journal of Sports Physical Therapy2159-28962024-03-01193The Validity of a Portable Strain-Gauge Apparatus Versus a Commercial Isokinetic Dynamometer for Evaluating Knee Extension KineticsDustin OranchukChris JuneauShelley DiewaldJono NevilleJohn Cronin# Background Isokinetic dynamometers are widely used when assessing neuromuscular function including knee extension kinetics. However, these dynamometers are often prohibitively expensive and are not portable. Thus strain-gauge technology has grown in popularity. # Purpose The purpose of this study was to compare kinetic data captured via an isokinetic dynamometer against an affordable and portable strain-gauge with a treatment plinth during maximal isometric knee extensions. # Study Design Cross-sectional study. # Methods Healthy participants (8 males and 6 females; age 30.2±7.1 years) volunteered and performed knee extensions at a 90° knee angle on a dynamometer and a treatment plinth with a portable strain-gauge. Peak force (PF), peak rate of force development (PRFD), rate of force development (RFD~2080~) and impulse (IMP~2080~) from 20-80% of onset to peak force were assessed using both strain-gauge and isokinetic dynamometer. Between-device differences were evaluated by the Wilcoxon signed-rank test, Cohen's *d* effect sizes (ES), Pearson's correlation coefficients (*r*), and Bland-Altman plots. # Results No significant or meaningful differences were identified between isokinetic and strain-gauge devices (all *p*≥0.268, ES≤0.35). However, slightly greater (2.5-9.5%) outputs were observed with the isokinetic dynamometer. Very large significant between-device correlations were found for PF (*r*=0.77, *p*=0.001) and PRFD (*r*=0.73, *p*=0.003), while small and moderate non-significant between-device correlations were found for RFD~2080~ (*r*=0.48, *p*=0.079) and IMP~2080~ (*r*=0.59, *p*=0.060). Bland-Altman plots did not reveal apparent biases from high to low performers. # Conclusions These results indicate that the strain-gauge device can produce valid maximal and rapid force expression measurements. Similar results, such as those quantified via an isokinetic device, can be obtained without extreme rigour and constraint. The study's findings support using the practically relevant treatment plinth and strain-gauge combination as a suitable alternative to the isokinetic dynamometry for measuring PF and PRFD. Therefore, more rehabilitation and sports performance practitioners can confidently assess knee extension kinetics. # Level of Evidence 3https://doi.org/10.26603/001c.92742
spellingShingle Dustin Oranchuk
Chris Juneau
Shelley Diewald
Jono Neville
John Cronin
The Validity of a Portable Strain-Gauge Apparatus Versus a Commercial Isokinetic Dynamometer for Evaluating Knee Extension Kinetics
International Journal of Sports Physical Therapy
title The Validity of a Portable Strain-Gauge Apparatus Versus a Commercial Isokinetic Dynamometer for Evaluating Knee Extension Kinetics
title_full The Validity of a Portable Strain-Gauge Apparatus Versus a Commercial Isokinetic Dynamometer for Evaluating Knee Extension Kinetics
title_fullStr The Validity of a Portable Strain-Gauge Apparatus Versus a Commercial Isokinetic Dynamometer for Evaluating Knee Extension Kinetics
title_full_unstemmed The Validity of a Portable Strain-Gauge Apparatus Versus a Commercial Isokinetic Dynamometer for Evaluating Knee Extension Kinetics
title_short The Validity of a Portable Strain-Gauge Apparatus Versus a Commercial Isokinetic Dynamometer for Evaluating Knee Extension Kinetics
title_sort validity of a portable strain gauge apparatus versus a commercial isokinetic dynamometer for evaluating knee extension kinetics
url https://doi.org/10.26603/001c.92742
work_keys_str_mv AT dustinoranchuk thevalidityofaportablestraingaugeapparatusversusacommercialisokineticdynamometerforevaluatingkneeextensionkinetics
AT chrisjuneau thevalidityofaportablestraingaugeapparatusversusacommercialisokineticdynamometerforevaluatingkneeextensionkinetics
AT shelleydiewald thevalidityofaportablestraingaugeapparatusversusacommercialisokineticdynamometerforevaluatingkneeextensionkinetics
AT jononeville thevalidityofaportablestraingaugeapparatusversusacommercialisokineticdynamometerforevaluatingkneeextensionkinetics
AT johncronin thevalidityofaportablestraingaugeapparatusversusacommercialisokineticdynamometerforevaluatingkneeextensionkinetics
AT dustinoranchuk validityofaportablestraingaugeapparatusversusacommercialisokineticdynamometerforevaluatingkneeextensionkinetics
AT chrisjuneau validityofaportablestraingaugeapparatusversusacommercialisokineticdynamometerforevaluatingkneeextensionkinetics
AT shelleydiewald validityofaportablestraingaugeapparatusversusacommercialisokineticdynamometerforevaluatingkneeextensionkinetics
AT jononeville validityofaportablestraingaugeapparatusversusacommercialisokineticdynamometerforevaluatingkneeextensionkinetics
AT johncronin validityofaportablestraingaugeapparatusversusacommercialisokineticdynamometerforevaluatingkneeextensionkinetics