DDC_Calc, software to diagnose developmental dysplasia of the hip in infants (version 1)
<strong>Background</strong>: developmental dysplasia of the hip constitutes the most frequent affection for the development of the musculoskeletal system. In the context of radiographic diagnosis of this disease in infants, digital radiographs offer advantages that could be used for a mo...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | Spanish |
Published: |
Centro Provincial de Información de Ciencias Médicas. Cienfuegos
2023-02-01
|
Series: | Medisur |
Subjects: | |
Online Access: | http://medisur.sld.cu/index.php/medisur/article/view/5574 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832576893326458880 |
---|---|
author | José Julio Requeiro Molina Ernesto Pérez Pérez Ana María Machado Consuegra Karina Leonor Fernández Sánchez Roberto Díaz Amador José Julio Requeiro Morejón |
author_facet | José Julio Requeiro Molina Ernesto Pérez Pérez Ana María Machado Consuegra Karina Leonor Fernández Sánchez Roberto Díaz Amador José Julio Requeiro Morejón |
author_sort | José Julio Requeiro Molina |
collection | DOAJ |
description | <strong>Background</strong>: developmental dysplasia of the hip constitutes the most frequent affection for the development of the musculoskeletal system. In the context of radiographic diagnosis of this disease in infants, digital radiographs offer advantages that could be used for a more accurate diagnosis. <br /><strong>Objective</strong>: to describe the DDC_Calc software operation to perform radiographic measurements in digital format. <br /><strong>Methods</strong>: a technological innovation study was carried out during 2019, at the Paquito González Cueto University Pediatric Hospital, in Cienfuegos, specifically in the Orthopedics Service and with the specialists’ contribution from the "Marta Abreu" Central University’ Mathematics, Physics and Computing Faculty, Las Villas. The Viola-Jones artificial vision algorithm was used for the detection of the structures, as well as a rule-based system with a view to a diagnostic suggestion. <br /><strong>Results</strong>: the software integrated the necessary tools to carry out the measurements used (angles, distances, positions) in the radiographic diagnosis of developmental dysplasia of the hip. Its functionalities, requirements and operation of the application were described, based on a real clinical case, all illustrated with images. <br /><strong>Conclusions</strong>: the use of the software facilitates the performance of more accurate measurements by the doctor, thus guaranteeing higher quality in the diagnosis and the preservation of the initial radiographic findings, which are very useful in the radiographic follow-up of the condition in time. |
format | Article |
id | doaj-art-59fe0af6541a4cd4bead9dee499a616e |
institution | Kabale University |
issn | 1727-897X |
language | Spanish |
publishDate | 2023-02-01 |
publisher | Centro Provincial de Información de Ciencias Médicas. Cienfuegos |
record_format | Article |
series | Medisur |
spelling | doaj-art-59fe0af6541a4cd4bead9dee499a616e2025-01-30T21:29:00ZspaCentro Provincial de Información de Ciencias Médicas. CienfuegosMedisur1727-897X2023-02-012111361632259DDC_Calc, software to diagnose developmental dysplasia of the hip in infants (version 1)José Julio Requeiro Molina0Ernesto Pérez Pérez1Ana María Machado Consuegra2Karina Leonor Fernández Sánchez3Roberto Díaz Amador4José Julio Requeiro Morejón5Hospital Pediátrico Universitario Paquito González Cueto. CienfuegosUniversidad Central “Marta Abreu” de Las Villas. Villa ClaraHospital Pediátrico Universitario Paquito González Cueto. CienfuegosUniversidad Central “Marta Abreu” de Las Villas. Villa ClaraUniversidad Central “Marta Abreu” de Las Villas. Villa ClaraHogar de Ancianos My Cape Breton. Sidney<strong>Background</strong>: developmental dysplasia of the hip constitutes the most frequent affection for the development of the musculoskeletal system. In the context of radiographic diagnosis of this disease in infants, digital radiographs offer advantages that could be used for a more accurate diagnosis. <br /><strong>Objective</strong>: to describe the DDC_Calc software operation to perform radiographic measurements in digital format. <br /><strong>Methods</strong>: a technological innovation study was carried out during 2019, at the Paquito González Cueto University Pediatric Hospital, in Cienfuegos, specifically in the Orthopedics Service and with the specialists’ contribution from the "Marta Abreu" Central University’ Mathematics, Physics and Computing Faculty, Las Villas. The Viola-Jones artificial vision algorithm was used for the detection of the structures, as well as a rule-based system with a view to a diagnostic suggestion. <br /><strong>Results</strong>: the software integrated the necessary tools to carry out the measurements used (angles, distances, positions) in the radiographic diagnosis of developmental dysplasia of the hip. Its functionalities, requirements and operation of the application were described, based on a real clinical case, all illustrated with images. <br /><strong>Conclusions</strong>: the use of the software facilitates the performance of more accurate measurements by the doctor, thus guaranteeing higher quality in the diagnosis and the preservation of the initial radiographic findings, which are very useful in the radiographic follow-up of the condition in time.http://medisur.sld.cu/index.php/medisur/article/view/5574programas informáticosultrasonografíaluxación congénita de la cadera |
spellingShingle | José Julio Requeiro Molina Ernesto Pérez Pérez Ana María Machado Consuegra Karina Leonor Fernández Sánchez Roberto Díaz Amador José Julio Requeiro Morejón DDC_Calc, software to diagnose developmental dysplasia of the hip in infants (version 1) Medisur programas informáticos ultrasonografía luxación congénita de la cadera |
title | DDC_Calc, software to diagnose developmental dysplasia of the hip in infants (version 1) |
title_full | DDC_Calc, software to diagnose developmental dysplasia of the hip in infants (version 1) |
title_fullStr | DDC_Calc, software to diagnose developmental dysplasia of the hip in infants (version 1) |
title_full_unstemmed | DDC_Calc, software to diagnose developmental dysplasia of the hip in infants (version 1) |
title_short | DDC_Calc, software to diagnose developmental dysplasia of the hip in infants (version 1) |
title_sort | ddc calc software to diagnose developmental dysplasia of the hip in infants version 1 |
topic | programas informáticos ultrasonografía luxación congénita de la cadera |
url | http://medisur.sld.cu/index.php/medisur/article/view/5574 |
work_keys_str_mv | AT josejuliorequeiromolina ddccalcsoftwaretodiagnosedevelopmentaldysplasiaofthehipininfantsversion1 AT ernestoperezperez ddccalcsoftwaretodiagnosedevelopmentaldysplasiaofthehipininfantsversion1 AT anamariamachadoconsuegra ddccalcsoftwaretodiagnosedevelopmentaldysplasiaofthehipininfantsversion1 AT karinaleonorfernandezsanchez ddccalcsoftwaretodiagnosedevelopmentaldysplasiaofthehipininfantsversion1 AT robertodiazamador ddccalcsoftwaretodiagnosedevelopmentaldysplasiaofthehipininfantsversion1 AT josejuliorequeiromorejon ddccalcsoftwaretodiagnosedevelopmentaldysplasiaofthehipininfantsversion1 |