Analysis of the Influence of Different Scanning Conditions of Medical Linear Accelerator CBCT on Image Quality

ObjectiveTo investigate the influence of different scanning conditions on the image quality of medical electron accelerator cone-beam computed tomography (CBCT) and provide a reference for the selection of scanning conditions for different body parts. Methods Set different scanning conditions, the C...

Full description

Saved in:
Bibliographic Details
Main Authors: Li LIU, Chengwei YE, Jianjun YUAN, Yingui LUO, Zhiyao LUO, Wei ZENG, Ling LI, Huan LIU, Yan LIU
Format: Article
Language:zho
Published: Editorial Office of Chinese Journal of Medical Instrumentation 2025-03-01
Series:Zhongguo yiliao qixie zazhi
Subjects:
Online Access:https://zgylqxzz.xml-journal.net/article/doi/10.12455/j.issn.1671-7104.240480
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849700962687516672
author Li LIU
Chengwei YE
Jianjun YUAN
Yingui LUO
Zhiyao LUO
Wei ZENG
Ling LI
Huan LIU
Yan LIU
author_facet Li LIU
Chengwei YE
Jianjun YUAN
Yingui LUO
Zhiyao LUO
Wei ZENG
Ling LI
Huan LIU
Yan LIU
author_sort Li LIU
collection DOAJ
description ObjectiveTo investigate the influence of different scanning conditions on the image quality of medical electron accelerator cone-beam computed tomography (CBCT) and provide a reference for the selection of scanning conditions for different body parts. Methods Set different scanning conditions, the Catphan 503 phantom was scanned using CBCT parameters to analyze the influence of spatial resolution, noise, uniformity, spatial geometric accuracy, and low-contrast resolution on the image quality of CBCT. Results For the head, chest, and abdomen, with the increase in scanning parameter values, the noise value decreased by 47.4%, 26.1%, and 51.3% respectively, and the uniformity values decreased by 30.2%, 26.6%, and 47.9% respectively. The low-contrast resolution values decreased by 50.6%, 34.2%, and 12.0%. The influence of different scanning conditions on spatial geometric accuracy and spatial resolution is not significant. ConclusionDifferent scanning parameters have a certain influence on the image quality of medical electron accelerator CBCT. Lower scanning parameters can be selected based on individual patients to reduce the additional radiation dose, providing a reference for the safe application of CBCT image guidance in radiotherapy.
format Article
id doaj-art-58f4a4a5e4b3475cad6bb6d2376e902c
institution DOAJ
issn 1671-7104
language zho
publishDate 2025-03-01
publisher Editorial Office of Chinese Journal of Medical Instrumentation
record_format Article
series Zhongguo yiliao qixie zazhi
spelling doaj-art-58f4a4a5e4b3475cad6bb6d2376e902c2025-08-20T03:18:06ZzhoEditorial Office of Chinese Journal of Medical InstrumentationZhongguo yiliao qixie zazhi1671-71042025-03-0149217618010.12455/j.issn.1671-7104.2404802024-0480Analysis of the Influence of Different Scanning Conditions of Medical Linear Accelerator CBCT on Image QualityLi LIU0Chengwei YE1Jianjun YUAN2Yingui LUO3Zhiyao LUO4Wei ZENG5Ling LI6Huan LIU7Yan LIU8Department of Oncology, Deyang People’s Hospital, Deyang, 618000Department of Oncology, Deyang People’s Hospital, Deyang, 618000Department of Oncology, Deyang People’s Hospital, Deyang, 618000Department of Oncology, Deyang People’s Hospital, Deyang, 618000Department of Oncology, Deyang People’s Hospital, Deyang, 618000Department of Oncology, Deyang People’s Hospital, Deyang, 618000Department of Oncology, Deyang People’s Hospital, Deyang, 618000Department of Oncology, Deyang People’s Hospital, Deyang, 618000Department of Oncology, Deyang People’s Hospital, Deyang, 618000ObjectiveTo investigate the influence of different scanning conditions on the image quality of medical electron accelerator cone-beam computed tomography (CBCT) and provide a reference for the selection of scanning conditions for different body parts. Methods Set different scanning conditions, the Catphan 503 phantom was scanned using CBCT parameters to analyze the influence of spatial resolution, noise, uniformity, spatial geometric accuracy, and low-contrast resolution on the image quality of CBCT. Results For the head, chest, and abdomen, with the increase in scanning parameter values, the noise value decreased by 47.4%, 26.1%, and 51.3% respectively, and the uniformity values decreased by 30.2%, 26.6%, and 47.9% respectively. The low-contrast resolution values decreased by 50.6%, 34.2%, and 12.0%. The influence of different scanning conditions on spatial geometric accuracy and spatial resolution is not significant. ConclusionDifferent scanning parameters have a certain influence on the image quality of medical electron accelerator CBCT. Lower scanning parameters can be selected based on individual patients to reduce the additional radiation dose, providing a reference for the safe application of CBCT image guidance in radiotherapy.https://zgylqxzz.xml-journal.net/article/doi/10.12455/j.issn.1671-7104.240480catphan 503 phantomradiotherapyscanning conditionscone-beam ctimage quality
spellingShingle Li LIU
Chengwei YE
Jianjun YUAN
Yingui LUO
Zhiyao LUO
Wei ZENG
Ling LI
Huan LIU
Yan LIU
Analysis of the Influence of Different Scanning Conditions of Medical Linear Accelerator CBCT on Image Quality
Zhongguo yiliao qixie zazhi
catphan 503 phantom
radiotherapy
scanning conditions
cone-beam ct
image quality
title Analysis of the Influence of Different Scanning Conditions of Medical Linear Accelerator CBCT on Image Quality
title_full Analysis of the Influence of Different Scanning Conditions of Medical Linear Accelerator CBCT on Image Quality
title_fullStr Analysis of the Influence of Different Scanning Conditions of Medical Linear Accelerator CBCT on Image Quality
title_full_unstemmed Analysis of the Influence of Different Scanning Conditions of Medical Linear Accelerator CBCT on Image Quality
title_short Analysis of the Influence of Different Scanning Conditions of Medical Linear Accelerator CBCT on Image Quality
title_sort analysis of the influence of different scanning conditions of medical linear accelerator cbct on image quality
topic catphan 503 phantom
radiotherapy
scanning conditions
cone-beam ct
image quality
url https://zgylqxzz.xml-journal.net/article/doi/10.12455/j.issn.1671-7104.240480
work_keys_str_mv AT liliu analysisoftheinfluenceofdifferentscanningconditionsofmedicallinearacceleratorcbctonimagequality
AT chengweiye analysisoftheinfluenceofdifferentscanningconditionsofmedicallinearacceleratorcbctonimagequality
AT jianjunyuan analysisoftheinfluenceofdifferentscanningconditionsofmedicallinearacceleratorcbctonimagequality
AT yinguiluo analysisoftheinfluenceofdifferentscanningconditionsofmedicallinearacceleratorcbctonimagequality
AT zhiyaoluo analysisoftheinfluenceofdifferentscanningconditionsofmedicallinearacceleratorcbctonimagequality
AT weizeng analysisoftheinfluenceofdifferentscanningconditionsofmedicallinearacceleratorcbctonimagequality
AT lingli analysisoftheinfluenceofdifferentscanningconditionsofmedicallinearacceleratorcbctonimagequality
AT huanliu analysisoftheinfluenceofdifferentscanningconditionsofmedicallinearacceleratorcbctonimagequality
AT yanliu analysisoftheinfluenceofdifferentscanningconditionsofmedicallinearacceleratorcbctonimagequality