Use of diagnostic nanosecond X-ray pulse apparatuses
Objective. The study the specific features of using diagnostic nanosecond X-ray pulse apparatuses versus X-ray diagnostic apparatuses using direct current X-ray tubes.Material and methods. Dosimetric tests of ARDP-01 and Yasen-01 X-ray pulse apparatuses versus RUM20 and Siemens Axiom Iconos R200 app...
Saved in:
| Main Authors: | , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Luchevaya Diagnostika, LLC
2016-02-01
|
| Series: | Вестник рентгенологии и радиологии |
| Subjects: | |
| Online Access: | https://www.russianradiology.ru/jour/article/view/19 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850066004937277440 |
|---|---|
| author | S. N. Вayankin I. E. Mozharova V. L. Kuznetsov S. R. Korzhenevskiy A. A. Komarskiy |
| author_facet | S. N. Вayankin I. E. Mozharova V. L. Kuznetsov S. R. Korzhenevskiy A. A. Komarskiy |
| author_sort | S. N. Вayankin |
| collection | DOAJ |
| description | Objective. The study the specific features of using diagnostic nanosecond X-ray pulse apparatuses versus X-ray diagnostic apparatuses using direct current X-ray tubes.Material and methods. Dosimetric tests of ARDP-01 and Yasen-01 X-ray pulse apparatuses versus RUM20 and Siemens Axiom Iconos R200 apparatuses using direct current X-ray tubes were carried out.Results. The tests established that the patient radiation dose by a Yasen-01 apparatus is 2.5–3 times lower than that by a Siemens Axiom Iconos R200 apparatus. The radiation dose by an ARDP-01 apparatus was 10–20 times lower than that by a RUM20 apparatus when using film radiation detectors.Conclusion. The performed investigations demonstrate a manifold reduction in the lower X-ray radiation with the use of nanosecond X-ray pulse apparatuses as compared to the continuous radiation. Without changing the characteristics of a radiation detector, the dose can be further reduced by increasing the amplitude and decreasing the duration of the pulse of X-ray tube current, and raising the pulse ratio. |
| format | Article |
| id | doaj-art-58ee65e478f443909166c9f0d4a98b84 |
| institution | DOAJ |
| issn | 0042-4676 2619-0478 |
| language | English |
| publishDate | 2016-02-01 |
| publisher | Luchevaya Diagnostika, LLC |
| record_format | Article |
| series | Вестник рентгенологии и радиологии |
| spelling | doaj-art-58ee65e478f443909166c9f0d4a98b842025-08-20T02:48:53ZengLuchevaya Diagnostika, LLCВестник рентгенологии и радиологии0042-46762619-04782016-02-0102424610.20862/0042-4676-2015-0-2-42-4619Use of diagnostic nanosecond X-ray pulse apparatusesS. N. Вayankin0I. E. Mozharova1V. L. Kuznetsov2S. R. Korzhenevskiy3A. A. Komarskiy4Sverdlovsk Regional Oncology DispensarySverdlovsk Regional Clinical Neuropsychiatric Hospital for War VeteransInstitute of Electrophysics, Ural Branch of the Russian Academy of SciencesInstitute of Electrophysics, Ural Branch of the Russian Academy of SciencesInstitute of Electrophysics, Ural Branch of the Russian Academy of SciencesObjective. The study the specific features of using diagnostic nanosecond X-ray pulse apparatuses versus X-ray diagnostic apparatuses using direct current X-ray tubes.Material and methods. Dosimetric tests of ARDP-01 and Yasen-01 X-ray pulse apparatuses versus RUM20 and Siemens Axiom Iconos R200 apparatuses using direct current X-ray tubes were carried out.Results. The tests established that the patient radiation dose by a Yasen-01 apparatus is 2.5–3 times lower than that by a Siemens Axiom Iconos R200 apparatus. The radiation dose by an ARDP-01 apparatus was 10–20 times lower than that by a RUM20 apparatus when using film radiation detectors.Conclusion. The performed investigations demonstrate a manifold reduction in the lower X-ray radiation with the use of nanosecond X-ray pulse apparatuses as compared to the continuous radiation. Without changing the characteristics of a radiation detector, the dose can be further reduced by increasing the amplitude and decreasing the duration of the pulse of X-ray tube current, and raising the pulse ratio.https://www.russianradiology.ru/jour/article/view/19x-ray diagnosisnanosecond x-ray pulse apparatusesdose reduction |
| spellingShingle | S. N. Вayankin I. E. Mozharova V. L. Kuznetsov S. R. Korzhenevskiy A. A. Komarskiy Use of diagnostic nanosecond X-ray pulse apparatuses Вестник рентгенологии и радиологии x-ray diagnosis nanosecond x-ray pulse apparatuses dose reduction |
| title | Use of diagnostic nanosecond X-ray pulse apparatuses |
| title_full | Use of diagnostic nanosecond X-ray pulse apparatuses |
| title_fullStr | Use of diagnostic nanosecond X-ray pulse apparatuses |
| title_full_unstemmed | Use of diagnostic nanosecond X-ray pulse apparatuses |
| title_short | Use of diagnostic nanosecond X-ray pulse apparatuses |
| title_sort | use of diagnostic nanosecond x ray pulse apparatuses |
| topic | x-ray diagnosis nanosecond x-ray pulse apparatuses dose reduction |
| url | https://www.russianradiology.ru/jour/article/view/19 |
| work_keys_str_mv | AT snvayankin useofdiagnosticnanosecondxraypulseapparatuses AT iemozharova useofdiagnosticnanosecondxraypulseapparatuses AT vlkuznetsov useofdiagnosticnanosecondxraypulseapparatuses AT srkorzhenevskiy useofdiagnosticnanosecondxraypulseapparatuses AT aakomarskiy useofdiagnosticnanosecondxraypulseapparatuses |