Visual Outcomes and Patient Satisfaction with a Hydrophobic Acrylic Monofocal IOL Delivered Using a Manual System

Joseph Christenbury,1 Brad Hall2 1Eye Consultants of Atlanta, Atlanta, GA, USA; 2Sengi, Penniac, NB, CanadaCorrespondence: Joseph Christenbury, Eye Consultants of Atlanta, Atlanta, GA, USA, Tel +1-404-351-2220, Email jchristenbury@eyeconsultants.netPurpose: To evaluate visual outcomes and patient sa...

Full description

Saved in:
Bibliographic Details
Main Authors: Christenbury J, Hall B
Format: Article
Language:English
Published: Dove Medical Press 2024-11-01
Series:Clinical Ophthalmology
Subjects:
Online Access:https://www.dovepress.com/visual-outcomes-and-patient-satisfaction-with-a-hydrophobic-acrylic-mo-peer-reviewed-fulltext-article-OPTH
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849220962346598400
author Christenbury J
Hall B
author_facet Christenbury J
Hall B
author_sort Christenbury J
collection DOAJ
description Joseph Christenbury,1 Brad Hall2 1Eye Consultants of Atlanta, Atlanta, GA, USA; 2Sengi, Penniac, NB, CanadaCorrespondence: Joseph Christenbury, Eye Consultants of Atlanta, Atlanta, GA, USA, Tel +1-404-351-2220, Email jchristenbury@eyeconsultants.netPurpose: To evaluate visual outcomes and patient satisfaction at far and intermediate distances, up to 3 months postoperatively, in patients implanted with a hydrophobic acrylic intraocular lens (IOL) using a manual delivery system.Methods: This was a prospective single-arm study of visual outcomes and patient satisfaction after successful bilateral cataract surgery with the Clareon monofocal and monofocal toric IOL using the Monarch IV delivery system. Endpoints included bilateral visual acuity, manifest refraction, and satisfaction assessed at 1 and 3 months post-operatively, as well as a surgeon survey of in-the-bag placement and satisfaction.Results: A total of 28 patients (56 eyes) completed the study. At 3 months postoperatively, mean uncorrected and corrected binocular visual acuities at distance were 0.03 ± 0.04 logMAR and 0.00 ± 0.02 logMAR, respectively. For intermediate vision (66cm), 98% of eyes (55/56) had corrected monocular visual acuity 20/25 or better. In addition, mean uncorrected and corrected binocular visual acuities at intermediate (66cm) were 0.09 ± 0.05 logMAR and 0.04 ± 0.05 logMAR, respectively. Patient reported satisfaction with their vision was 88% (25/28). The IOL was delivered smoothly into the capsular bag in 89% (50/56) of eyes.Conclusion: Clareon monofocal and monofocal toric IOL delivered with Monarch IV can provide excellent distance vision and intermediate vision, good spectacle independence, high reported patient satisfaction, consistent in-the-bag delivery, and high surgeon satisfaction.Plain Language Summary: When the natural lens inside the eye becomes opaque (develops a cataract) it can be removed and replaced with an artificial intraocular lens (IOL). There are many different types of IOLs available for patients and surgeons to choose from. Monofocal IOLs are traditionally designed to provide clear vision at a single distance. However, recent advancements in optical designs for monofocal IOLs may provide functional vision when viewing objects at intermediate distances. The purpose of this study was to evaluate visual outcomes and patient satisfaction in patients with a new monofocal IOL, implanted with a manual delivery system, up to 3 months postoperatively. The results of this study suggest that the Clareon monofocal and monofocal toric IOL delivered with Monarch IV delivery system can provide excellent distance vision and functional intermediate vision.Keywords: cataract surgery, monofocal, clareon, monarch IV
format Article
id doaj-art-5877cf87d18943e38e4d60efe6875af9
institution Kabale University
issn 1177-5483
language English
publishDate 2024-11-01
publisher Dove Medical Press
record_format Article
series Clinical Ophthalmology
spelling doaj-art-5877cf87d18943e38e4d60efe6875af92024-11-26T17:58:43ZengDove Medical PressClinical Ophthalmology1177-54832024-11-01Volume 183485349197711Visual Outcomes and Patient Satisfaction with a Hydrophobic Acrylic Monofocal IOL Delivered Using a Manual SystemChristenbury JHall BJoseph Christenbury,1 Brad Hall2 1Eye Consultants of Atlanta, Atlanta, GA, USA; 2Sengi, Penniac, NB, CanadaCorrespondence: Joseph Christenbury, Eye Consultants of Atlanta, Atlanta, GA, USA, Tel +1-404-351-2220, Email jchristenbury@eyeconsultants.netPurpose: To evaluate visual outcomes and patient satisfaction at far and intermediate distances, up to 3 months postoperatively, in patients implanted with a hydrophobic acrylic intraocular lens (IOL) using a manual delivery system.Methods: This was a prospective single-arm study of visual outcomes and patient satisfaction after successful bilateral cataract surgery with the Clareon monofocal and monofocal toric IOL using the Monarch IV delivery system. Endpoints included bilateral visual acuity, manifest refraction, and satisfaction assessed at 1 and 3 months post-operatively, as well as a surgeon survey of in-the-bag placement and satisfaction.Results: A total of 28 patients (56 eyes) completed the study. At 3 months postoperatively, mean uncorrected and corrected binocular visual acuities at distance were 0.03 ± 0.04 logMAR and 0.00 ± 0.02 logMAR, respectively. For intermediate vision (66cm), 98% of eyes (55/56) had corrected monocular visual acuity 20/25 or better. In addition, mean uncorrected and corrected binocular visual acuities at intermediate (66cm) were 0.09 ± 0.05 logMAR and 0.04 ± 0.05 logMAR, respectively. Patient reported satisfaction with their vision was 88% (25/28). The IOL was delivered smoothly into the capsular bag in 89% (50/56) of eyes.Conclusion: Clareon monofocal and monofocal toric IOL delivered with Monarch IV can provide excellent distance vision and intermediate vision, good spectacle independence, high reported patient satisfaction, consistent in-the-bag delivery, and high surgeon satisfaction.Plain Language Summary: When the natural lens inside the eye becomes opaque (develops a cataract) it can be removed and replaced with an artificial intraocular lens (IOL). There are many different types of IOLs available for patients and surgeons to choose from. Monofocal IOLs are traditionally designed to provide clear vision at a single distance. However, recent advancements in optical designs for monofocal IOLs may provide functional vision when viewing objects at intermediate distances. The purpose of this study was to evaluate visual outcomes and patient satisfaction in patients with a new monofocal IOL, implanted with a manual delivery system, up to 3 months postoperatively. The results of this study suggest that the Clareon monofocal and monofocal toric IOL delivered with Monarch IV delivery system can provide excellent distance vision and functional intermediate vision.Keywords: cataract surgery, monofocal, clareon, monarch IVhttps://www.dovepress.com/visual-outcomes-and-patient-satisfaction-with-a-hydrophobic-acrylic-mo-peer-reviewed-fulltext-article-OPTHcataract surgerymonofocalclareonmonarch iv
spellingShingle Christenbury J
Hall B
Visual Outcomes and Patient Satisfaction with a Hydrophobic Acrylic Monofocal IOL Delivered Using a Manual System
Clinical Ophthalmology
cataract surgery
monofocal
clareon
monarch iv
title Visual Outcomes and Patient Satisfaction with a Hydrophobic Acrylic Monofocal IOL Delivered Using a Manual System
title_full Visual Outcomes and Patient Satisfaction with a Hydrophobic Acrylic Monofocal IOL Delivered Using a Manual System
title_fullStr Visual Outcomes and Patient Satisfaction with a Hydrophobic Acrylic Monofocal IOL Delivered Using a Manual System
title_full_unstemmed Visual Outcomes and Patient Satisfaction with a Hydrophobic Acrylic Monofocal IOL Delivered Using a Manual System
title_short Visual Outcomes and Patient Satisfaction with a Hydrophobic Acrylic Monofocal IOL Delivered Using a Manual System
title_sort visual outcomes and patient satisfaction with a hydrophobic acrylic monofocal iol delivered using a manual system
topic cataract surgery
monofocal
clareon
monarch iv
url https://www.dovepress.com/visual-outcomes-and-patient-satisfaction-with-a-hydrophobic-acrylic-mo-peer-reviewed-fulltext-article-OPTH
work_keys_str_mv AT christenburyj visualoutcomesandpatientsatisfactionwithahydrophobicacrylicmonofocalioldeliveredusingamanualsystem
AT hallb visualoutcomesandpatientsatisfactionwithahydrophobicacrylicmonofocalioldeliveredusingamanualsystem