Efficacy and safety of fluocinolone acetonide intravitreal implant (0.2 µg/day) in patients with post-surgical inflammation associated with macular edema: a case series study
Abstract Background Postoperative cystoid macular edema (PCME) is a primary cause of reduced vision following both cataract and/or vitreoretinal surgery, which may spontaneously resolve. This study aimed to evaluate the effectiveness and safety of the fluocinolone acetonide intravitreal (FAc) implan...
Saved in:
| Main Authors: | , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
SpringerOpen
2025-08-01
|
| Series: | Journal of Ophthalmic Inflammation and Infection |
| Subjects: | |
| Online Access: | https://doi.org/10.1186/s12348-025-00503-8 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Summary: | Abstract Background Postoperative cystoid macular edema (PCME) is a primary cause of reduced vision following both cataract and/or vitreoretinal surgery, which may spontaneously resolve. This study aimed to evaluate the effectiveness and safety of the fluocinolone acetonide intravitreal (FAc) implant (0.2 µg/day) in patients with refractory PCME. Methods Retrospective, non-interventional, and single center study conducted on patients with PCME treated with 0.2 µg/day FAc implant. All the patients received previous treatment with topical corticosteroids, nonsteroidal anti-inflammatory drugs (NSAIDs), triancinolone injection and dexamethasone implant. The primary end-points were the mean change in best-corrected-visual-acuity (BCVA) and the proportion of patients gaining ≥ 15 letters from baseline to the last follow-up visit. The secondary endpoints included the mean CRT reduction and the mean intraocular pressure (IOP) during the 36 months study period. Results Eight eyes from 8 patients were included in the study. Median (95% Confidence-interval) BCVA was significantly improved from 60.0 (50.05–69.95) letters at baseline to 80.15 (77.25-85.00) letters at month-36, p = 0.043. At the last follow-up visit, 5 (62.5%) eyes gained ≥ 15 letters, without any eye experiencing a loss of BCVA compared to baseline. There was significant CRT reduction from baseline (median: 497.5 μm; 95%CI: 380.0–596.0 μm) to month-36 (Median: 252.0 μm; 95%CI: 242.0–268.0 μm); p = 0.012. Regarding safety, IOP remained stable from baseline (median: 14.5mmHg; 95%Confidence-interval: 12.0–23.0 mmHg) to the last follow-up visit (median: 13.5mmHg; 95% Confidence-interval: 9.0–19.0 mm Hg); p = 0.123. Conclusions The FAc implant significantly improved both visual and anatomic outcomes, and was effective in preventing recurrences, while maintaining a reasonable safety profile, in PCME refractory to intravitreal triancinolone and dexamethasone. |
|---|---|
| ISSN: | 1869-5760 |