Statistical analysis of the occupational radiation doses in three different positron emission tomography–computed tomography centers in Egypt

In the present study, we investigated the radiation doses received by the positron emission tomography (PET)/computed tomography (CT) staff in three different diagnostic centers in Egypt. The whole-body effective dose measured by thermoluminescent dosimeters (TLDs) for staff working in PET and the e...

Full description

Saved in:
Bibliographic Details
Main Authors: Ibrahim Elsayed Saad Ahmed, Abdulrahman M.M. Zamzam, Hossam Mahmoud Yassin
Format: Article
Language:English
Published: Thieme Medical and Scientific Publishers Pvt. Ltd. 2019-07-01
Series:World Journal of Nuclear Medicine
Subjects:
Online Access:http://www.thieme-connect.de/DOI/DOI?10.4103/wjnm.WJNM_42_18
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850045332608516096
author Ibrahim Elsayed Saad Ahmed
Abdulrahman M.M. Zamzam
Hossam Mahmoud Yassin
author_facet Ibrahim Elsayed Saad Ahmed
Abdulrahman M.M. Zamzam
Hossam Mahmoud Yassin
author_sort Ibrahim Elsayed Saad Ahmed
collection DOAJ
description In the present study, we investigated the radiation doses received by the positron emission tomography (PET)/computed tomography (CT) staff in three different diagnostic centers in Egypt. The whole-body effective dose measured by thermoluminescent dosimeters (TLDs) for staff working in PET and the effective dose per study received by physicist, technician, and nurse were measured by an electronic pocket dosimeter (EPD) during a period of 6 months. Statistical analysis was held between the measurements of the TLDs as well as for the EPD for the three studied PET-CT centers. After combining TLD and EPD prospective annual scores for the three studied categories in the three centers, the one-way ANOVA test results have shown that there were statistically significant differences between group means with respect to their TLD mean score (P = 0.041). The mean nurse group TLD score, across the three centers, appeared to be the lowest scoring 3.83 (standard deviation [SD] 0.012) compared to the physicist and technician who measured 4.62 (SD 0.231) and 6.92 (SD 0.018), respectively. Scheffe's test for complex comparisons revealed a significant difference between nurse group and technologist group (P = 0.001). Regarding the annual combined EPD scores, the post hoc test, namely Scheffe's test for complex comparisons, revealed a significant difference between nurse group and technologist group (P = 0.001). This was measured after the one-way ANOVA test results have shown that there were statistically significant differences between annual group EPD means (P = 0.032). Finally, there was no recorded significance for the studied categories across the three centers between their annual TLD and EPD dose scores (P = 0.072). Technicians group received the highest mean effective whole-body doses when compared with the International Commission on Radiological Protection dose limit, each individual worker can work with many more 18F-fluorodeoxyglucose (FDG) PET/CT studies for a (period time) without exceeding the occupational dose limits if the average received effective dose continues with the same rate. The study also confirmed that low levels of radiation dose are received by medical personnel involved in 18F-FDG PET/CT procedures in those centers due to implementing radiation protection measures and procedures.
format Article
id doaj-art-56de5084c44d431981bb3e1cbeebfdc2
institution DOAJ
issn 1450-1147
1607-3312
language English
publishDate 2019-07-01
publisher Thieme Medical and Scientific Publishers Pvt. Ltd.
record_format Article
series World Journal of Nuclear Medicine
spelling doaj-art-56de5084c44d431981bb3e1cbeebfdc22025-08-20T02:54:43ZengThieme Medical and Scientific Publishers Pvt. Ltd.World Journal of Nuclear Medicine1450-11471607-33122019-07-01180328729210.4103/wjnm.WJNM_42_18Statistical analysis of the occupational radiation doses in three different positron emission tomography–computed tomography centers in EgyptIbrahim Elsayed Saad Ahmed0Abdulrahman M.M. Zamzam1Hossam Mahmoud Yassin2Department of Clinical Oncology and Nuclear Medicine, Faculty of Medicine, Cairo University, Giza, EgyptDepartment of Nuclear Medicine Technology, Inaya Medical Colleges, Riyadh, Saudi ArabiaDepartment of Clinical Oncology and Nuclear Medicine, Faculty of Medicine, Cairo University, Giza, EgyptIn the present study, we investigated the radiation doses received by the positron emission tomography (PET)/computed tomography (CT) staff in three different diagnostic centers in Egypt. The whole-body effective dose measured by thermoluminescent dosimeters (TLDs) for staff working in PET and the effective dose per study received by physicist, technician, and nurse were measured by an electronic pocket dosimeter (EPD) during a period of 6 months. Statistical analysis was held between the measurements of the TLDs as well as for the EPD for the three studied PET-CT centers. After combining TLD and EPD prospective annual scores for the three studied categories in the three centers, the one-way ANOVA test results have shown that there were statistically significant differences between group means with respect to their TLD mean score (P = 0.041). The mean nurse group TLD score, across the three centers, appeared to be the lowest scoring 3.83 (standard deviation [SD] 0.012) compared to the physicist and technician who measured 4.62 (SD 0.231) and 6.92 (SD 0.018), respectively. Scheffe's test for complex comparisons revealed a significant difference between nurse group and technologist group (P = 0.001). Regarding the annual combined EPD scores, the post hoc test, namely Scheffe's test for complex comparisons, revealed a significant difference between nurse group and technologist group (P = 0.001). This was measured after the one-way ANOVA test results have shown that there were statistically significant differences between annual group EPD means (P = 0.032). Finally, there was no recorded significance for the studied categories across the three centers between their annual TLD and EPD dose scores (P = 0.072). Technicians group received the highest mean effective whole-body doses when compared with the International Commission on Radiological Protection dose limit, each individual worker can work with many more 18F-fluorodeoxyglucose (FDG) PET/CT studies for a (period time) without exceeding the occupational dose limits if the average received effective dose continues with the same rate. The study also confirmed that low levels of radiation dose are received by medical personnel involved in 18F-FDG PET/CT procedures in those centers due to implementing radiation protection measures and procedures.http://www.thieme-connect.de/DOI/DOI?10.4103/wjnm.WJNM_42_18analysisoccupational dosespositron emission tomography-computed tomography
spellingShingle Ibrahim Elsayed Saad Ahmed
Abdulrahman M.M. Zamzam
Hossam Mahmoud Yassin
Statistical analysis of the occupational radiation doses in three different positron emission tomography–computed tomography centers in Egypt
World Journal of Nuclear Medicine
analysis
occupational doses
positron emission tomography-computed tomography
title Statistical analysis of the occupational radiation doses in three different positron emission tomography–computed tomography centers in Egypt
title_full Statistical analysis of the occupational radiation doses in three different positron emission tomography–computed tomography centers in Egypt
title_fullStr Statistical analysis of the occupational radiation doses in three different positron emission tomography–computed tomography centers in Egypt
title_full_unstemmed Statistical analysis of the occupational radiation doses in three different positron emission tomography–computed tomography centers in Egypt
title_short Statistical analysis of the occupational radiation doses in three different positron emission tomography–computed tomography centers in Egypt
title_sort statistical analysis of the occupational radiation doses in three different positron emission tomography computed tomography centers in egypt
topic analysis
occupational doses
positron emission tomography-computed tomography
url http://www.thieme-connect.de/DOI/DOI?10.4103/wjnm.WJNM_42_18
work_keys_str_mv AT ibrahimelsayedsaadahmed statisticalanalysisoftheoccupationalradiationdosesinthreedifferentpositronemissiontomographycomputedtomographycentersinegypt
AT abdulrahmanmmzamzam statisticalanalysisoftheoccupationalradiationdosesinthreedifferentpositronemissiontomographycomputedtomographycentersinegypt
AT hossammahmoudyassin statisticalanalysisoftheoccupationalradiationdosesinthreedifferentpositronemissiontomographycomputedtomographycentersinegypt