Endotoxin Contamination of Large Volume Parenterals as Detected by Limulus Amebocyte Lysate as an Alternative to Rabbit Pyrogen Test

The possibility of replacing the rabbit pyrogen test by the Limulus Amebocyte lysate (LAL) test, as a final release test for Large Volume Parenterals (LVPs) was investigated. The sensitivity and specificity of the LAL test and rabbit pyrogen assay were studied by means of artificially contaminated p...

Full description

Saved in:
Bibliographic Details
Format: Article
Language:English
Published: University of Tehran 1989-12-01
Series:Journal of Sciences, Islamic Republic of Iran
Online Access:https://jsciences.ut.ac.ir/article_31167_232f95443fb8717f0212b86c79314a81.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850153052020932608
collection DOAJ
description The possibility of replacing the rabbit pyrogen test by the Limulus Amebocyte lysate (LAL) test, as a final release test for Large Volume Parenterals (LVPs) was investigated. The sensitivity and specificity of the LAL test and rabbit pyrogen assay were studied by means of artificially contaminated parenterals. Various LVPs (mostly containing electrolytes) were spiked with 0.5 and 5 EUlml of E.coli 01 11 :B4 endotoxin (Lambda =0.5 EUIml). The pH of the formulations were measured, and if necessary, adjusted to 5.5 - 8.0 by NaOH or HC1. Four of the products showed significant responses to the LAL test when the endotoxin concentration was 0.1 nglml. However, the remaining formulations required some degree of dilution prior to the test to overcome inhibition. The inhibitory effect caused by cations on the LAL reaction is enhanced by increases in valency. Therefore, the difference between the products in responding to the LAL test have resulted from shifts in the electrokinetic potentials between the LAL and the endotoxin. The rabbit test response was insignificant for all the solutions. The LAL test was found to be useful for the detection of bacterial endotoxin in LVPs. It also has the advantage of being more sensitive, rapid and reproducible than the rabbit pyrogen test
format Article
id doaj-art-5667f3d1ca144b9fad7152cc494856fc
institution OA Journals
issn 1016-1104
2345-6914
language English
publishDate 1989-12-01
publisher University of Tehran
record_format Article
series Journal of Sciences, Islamic Republic of Iran
spelling doaj-art-5667f3d1ca144b9fad7152cc494856fc2025-08-20T02:25:50ZengUniversity of TehranJournal of Sciences, Islamic Republic of Iran1016-11042345-69141989-12-011131167Endotoxin Contamination of Large Volume Parenterals as Detected by Limulus Amebocyte Lysate as an Alternative to Rabbit Pyrogen TestThe possibility of replacing the rabbit pyrogen test by the Limulus Amebocyte lysate (LAL) test, as a final release test for Large Volume Parenterals (LVPs) was investigated. The sensitivity and specificity of the LAL test and rabbit pyrogen assay were studied by means of artificially contaminated parenterals. Various LVPs (mostly containing electrolytes) were spiked with 0.5 and 5 EUlml of E.coli 01 11 :B4 endotoxin (Lambda =0.5 EUIml). The pH of the formulations were measured, and if necessary, adjusted to 5.5 - 8.0 by NaOH or HC1. Four of the products showed significant responses to the LAL test when the endotoxin concentration was 0.1 nglml. However, the remaining formulations required some degree of dilution prior to the test to overcome inhibition. The inhibitory effect caused by cations on the LAL reaction is enhanced by increases in valency. Therefore, the difference between the products in responding to the LAL test have resulted from shifts in the electrokinetic potentials between the LAL and the endotoxin. The rabbit test response was insignificant for all the solutions. The LAL test was found to be useful for the detection of bacterial endotoxin in LVPs. It also has the advantage of being more sensitive, rapid and reproducible than the rabbit pyrogen testhttps://jsciences.ut.ac.ir/article_31167_232f95443fb8717f0212b86c79314a81.pdf
spellingShingle Endotoxin Contamination of Large Volume Parenterals as Detected by Limulus Amebocyte Lysate as an Alternative to Rabbit Pyrogen Test
Journal of Sciences, Islamic Republic of Iran
title Endotoxin Contamination of Large Volume Parenterals as Detected by Limulus Amebocyte Lysate as an Alternative to Rabbit Pyrogen Test
title_full Endotoxin Contamination of Large Volume Parenterals as Detected by Limulus Amebocyte Lysate as an Alternative to Rabbit Pyrogen Test
title_fullStr Endotoxin Contamination of Large Volume Parenterals as Detected by Limulus Amebocyte Lysate as an Alternative to Rabbit Pyrogen Test
title_full_unstemmed Endotoxin Contamination of Large Volume Parenterals as Detected by Limulus Amebocyte Lysate as an Alternative to Rabbit Pyrogen Test
title_short Endotoxin Contamination of Large Volume Parenterals as Detected by Limulus Amebocyte Lysate as an Alternative to Rabbit Pyrogen Test
title_sort endotoxin contamination of large volume parenterals as detected by limulus amebocyte lysate as an alternative to rabbit pyrogen test
url https://jsciences.ut.ac.ir/article_31167_232f95443fb8717f0212b86c79314a81.pdf