Environmental gamma dose rate measurements using cadmium zinc telluride (CZT) detectors

<p>The accurate and precise determination of the environmental dose rate is pivotal in every trapped-charge dating study. The environmental <span class="inline-formula"><i>γ</i></span> dose rate component can be determined from radionuclide concentrations usin...

Full description

Saved in:
Bibliographic Details
Main Authors: S. Kreutzer, L. Martin, D. Miallier, N. Mercier
Format: Article
Language:English
Published: Copernicus Publications 2025-07-01
Series:Geochronology
Online Access:https://gchron.copernicus.org/articles/7/229/2025/gchron-7-229-2025.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849431115761188864
author S. Kreutzer
L. Martin
D. Miallier
N. Mercier
author_facet S. Kreutzer
L. Martin
D. Miallier
N. Mercier
author_sort S. Kreutzer
collection DOAJ
description <p>The accurate and precise determination of the environmental dose rate is pivotal in every trapped-charge dating study. The environmental <span class="inline-formula"><i>γ</i></span> dose rate component can be determined from radionuclide concentrations using conversion factors or directly measured in situ with passive or active detectors. In-field measurements with an active detector are usually inexpensive and straightforward to achieve with adequate equipment and calibration. However, despite the rather widespread use of portable NaI or <span class="inline-formula">LaBr<sub>3</sub></span> scintillator detectors, there is a lack of research on the performance and practicality of portable alternative detectors in dating studies, particularly in light of newer developments in the semi-conductor industry. Here, we present our experience with two small portable semi-conductor detectors housing cadmium zinc telluride (CZT) crystals. Given their small volume and low power consumption, we argue they present attractive alternatives for <span class="inline-formula"><i>γ</i></span> dose rate measurements in dating studies. Despite high relative detection efficiency, their small volume may pose different challenges, resulting in impractical measurements in routine studies, and therefore need investigation. In our study, we simulated the particle interaction of the CZT crystal with GEANT4 in different sediment matrices to quantify the energy threshold in the spectrum above which the count/energy count rate correlates with the environmental gamma dose rate irrespective of the origin of the <span class="inline-formula"><i>γ</i></span> photons. We compared these findings with experimentally derived cumulative spectra and dose rate calibration curves constructed from reference sites in France and Germany, which yielded unrealistically low threshold values, likely due to the limited variability of the investigated sites. We additionally report negligible equipment background and required minimal measurement time of only 20 <span class="inline-formula">min</span> in typical environments. Cross-checking our calibration on a homogeneous loess deposit near Heidelberg confirmed the setting and assumed performance through a nearly identical <span class="inline-formula"><i>γ</i></span> dose rate of 1107 <span class="inline-formula">±</span> 65 <span class="inline-formula">µGy a<sup>−1</sup></span> (CZT) to 1105 <span class="inline-formula">±</span> 11 <span class="inline-formula">µGy a<sup>−1</sup></span> (laboratory). The outcome of our study gives credit to our threshold definition. It validates the similarity of the two investigated probes, which may make it straightforward for other laboratories to implement the technique effortlessly. Finally, the implementation of CZT detectors has the potential to streamline fieldwork and enhance the accuracy and precision of trapped-charge dating-based chronologies.</p>
format Article
id doaj-art-55bcf320aaff4a1d89e659cb40426df4
institution Kabale University
issn 2628-3697
2628-3719
language English
publishDate 2025-07-01
publisher Copernicus Publications
record_format Article
series Geochronology
spelling doaj-art-55bcf320aaff4a1d89e659cb40426df42025-08-20T03:27:44ZengCopernicus PublicationsGeochronology2628-36972628-37192025-07-01722924610.5194/gchron-7-229-2025Environmental gamma dose rate measurements using cadmium zinc telluride (CZT) detectorsS. Kreutzer0L. Martin1D. Miallier2N. Mercier3Institute of Geography, Heidelberg University, Im Neuenheimer Feld 348, 69120 Heidelberg, GermanyInnsbruck Quaternary Research Group, University of Innsbruck, Innrain 52, 6020 Innsbruck, AustriaLaboratoire de Physique de Clermont-Ferrand, Université Clermont Auvergne, Campus des Cézeaux, 24, avenue des Landais BP 80026, 63171 Aubière CEDEX, FranceArchéosciences Bordeaux, CNRS-Université Bordeaux Montaigne, Maison de l'Archéologie, Esplanade des Antilles, 33607 Pessac CEDEX, France<p>The accurate and precise determination of the environmental dose rate is pivotal in every trapped-charge dating study. The environmental <span class="inline-formula"><i>γ</i></span> dose rate component can be determined from radionuclide concentrations using conversion factors or directly measured in situ with passive or active detectors. In-field measurements with an active detector are usually inexpensive and straightforward to achieve with adequate equipment and calibration. However, despite the rather widespread use of portable NaI or <span class="inline-formula">LaBr<sub>3</sub></span> scintillator detectors, there is a lack of research on the performance and practicality of portable alternative detectors in dating studies, particularly in light of newer developments in the semi-conductor industry. Here, we present our experience with two small portable semi-conductor detectors housing cadmium zinc telluride (CZT) crystals. Given their small volume and low power consumption, we argue they present attractive alternatives for <span class="inline-formula"><i>γ</i></span> dose rate measurements in dating studies. Despite high relative detection efficiency, their small volume may pose different challenges, resulting in impractical measurements in routine studies, and therefore need investigation. In our study, we simulated the particle interaction of the CZT crystal with GEANT4 in different sediment matrices to quantify the energy threshold in the spectrum above which the count/energy count rate correlates with the environmental gamma dose rate irrespective of the origin of the <span class="inline-formula"><i>γ</i></span> photons. We compared these findings with experimentally derived cumulative spectra and dose rate calibration curves constructed from reference sites in France and Germany, which yielded unrealistically low threshold values, likely due to the limited variability of the investigated sites. We additionally report negligible equipment background and required minimal measurement time of only 20 <span class="inline-formula">min</span> in typical environments. Cross-checking our calibration on a homogeneous loess deposit near Heidelberg confirmed the setting and assumed performance through a nearly identical <span class="inline-formula"><i>γ</i></span> dose rate of 1107 <span class="inline-formula">±</span> 65 <span class="inline-formula">µGy a<sup>−1</sup></span> (CZT) to 1105 <span class="inline-formula">±</span> 11 <span class="inline-formula">µGy a<sup>−1</sup></span> (laboratory). The outcome of our study gives credit to our threshold definition. It validates the similarity of the two investigated probes, which may make it straightforward for other laboratories to implement the technique effortlessly. Finally, the implementation of CZT detectors has the potential to streamline fieldwork and enhance the accuracy and precision of trapped-charge dating-based chronologies.</p>https://gchron.copernicus.org/articles/7/229/2025/gchron-7-229-2025.pdf
spellingShingle S. Kreutzer
L. Martin
D. Miallier
N. Mercier
Environmental gamma dose rate measurements using cadmium zinc telluride (CZT) detectors
Geochronology
title Environmental gamma dose rate measurements using cadmium zinc telluride (CZT) detectors
title_full Environmental gamma dose rate measurements using cadmium zinc telluride (CZT) detectors
title_fullStr Environmental gamma dose rate measurements using cadmium zinc telluride (CZT) detectors
title_full_unstemmed Environmental gamma dose rate measurements using cadmium zinc telluride (CZT) detectors
title_short Environmental gamma dose rate measurements using cadmium zinc telluride (CZT) detectors
title_sort environmental gamma dose rate measurements using cadmium zinc telluride czt detectors
url https://gchron.copernicus.org/articles/7/229/2025/gchron-7-229-2025.pdf
work_keys_str_mv AT skreutzer environmentalgammadoseratemeasurementsusingcadmiumzinctelluridecztdetectors
AT lmartin environmentalgammadoseratemeasurementsusingcadmiumzinctelluridecztdetectors
AT dmiallier environmentalgammadoseratemeasurementsusingcadmiumzinctelluridecztdetectors
AT nmercier environmentalgammadoseratemeasurementsusingcadmiumzinctelluridecztdetectors