A Solid Binding Matrix/Mimic Receptor-Based Sensor System for Trace Level Determination of Iron Using Potential Measurements

Iron(II)-(1,10-phenanthroline) complex imprinted membrane was prepared by ionic imprinting technology. In the first step, Fe(II) established a coordination linkage with 1,10-phenanthroline and functional monomer 2-vinylpyridine (2-VP). Next, the complex was copolymerized with ethylene glycol dimetha...

Full description

Saved in:
Bibliographic Details
Main Authors: Ayman H. Kamel, Felismina T. C. Moreira, Tamara I. Silva, M. Goreti F. Sales
Format: Article
Language:English
Published: Wiley 2011-01-01
Series:International Journal of Electrochemistry
Online Access:http://dx.doi.org/10.4061/2011/643683
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832566128743809024
author Ayman H. Kamel
Felismina T. C. Moreira
Tamara I. Silva
M. Goreti F. Sales
author_facet Ayman H. Kamel
Felismina T. C. Moreira
Tamara I. Silva
M. Goreti F. Sales
author_sort Ayman H. Kamel
collection DOAJ
description Iron(II)-(1,10-phenanthroline) complex imprinted membrane was prepared by ionic imprinting technology. In the first step, Fe(II) established a coordination linkage with 1,10-phenanthroline and functional monomer 2-vinylpyridine (2-VP). Next, the complex was copolymerized with ethylene glycol dimethacrylate (EGDMA) as a crosslinker in the presence of benzoyl peroxide (BPO) as an initiator. Potentiometric chemical sensors were designed by dispersing the iron(II)-imprinted polymer particles in 2-nitrophenyloctyl ether (o-NPOE) plasticizer and then embedded in poly vinyl chloride (PVC) matrix. The sensors showed a Nernstian response for [Fe(phen)3]2+ with limit of detection 3.15 ng mL−1 and a Nernstian slope of 35.7 mV per decade.
format Article
id doaj-art-551d8aef7e6149c89046c44c9b2d53ad
institution Kabale University
issn 2090-3537
language English
publishDate 2011-01-01
publisher Wiley
record_format Article
series International Journal of Electrochemistry
spelling doaj-art-551d8aef7e6149c89046c44c9b2d53ad2025-02-03T01:04:55ZengWileyInternational Journal of Electrochemistry2090-35372011-01-01201110.4061/2011/643683643683A Solid Binding Matrix/Mimic Receptor-Based Sensor System for Trace Level Determination of Iron Using Potential MeasurementsAyman H. Kamel0Felismina T. C. Moreira1Tamara I. Silva2M. Goreti F. Sales3REQUIMTE, Instituto Superior de Engenharia do Porto, Rua Benardino de Almeida 431, 4200-072 Porto, PortugalREQUIMTE, Instituto Superior de Engenharia do Porto, Rua Benardino de Almeida 431, 4200-072 Porto, PortugalREQUIMTE, Instituto Superior de Engenharia do Porto, Rua Benardino de Almeida 431, 4200-072 Porto, PortugalREQUIMTE, Instituto Superior de Engenharia do Porto, Rua Benardino de Almeida 431, 4200-072 Porto, PortugalIron(II)-(1,10-phenanthroline) complex imprinted membrane was prepared by ionic imprinting technology. In the first step, Fe(II) established a coordination linkage with 1,10-phenanthroline and functional monomer 2-vinylpyridine (2-VP). Next, the complex was copolymerized with ethylene glycol dimethacrylate (EGDMA) as a crosslinker in the presence of benzoyl peroxide (BPO) as an initiator. Potentiometric chemical sensors were designed by dispersing the iron(II)-imprinted polymer particles in 2-nitrophenyloctyl ether (o-NPOE) plasticizer and then embedded in poly vinyl chloride (PVC) matrix. The sensors showed a Nernstian response for [Fe(phen)3]2+ with limit of detection 3.15 ng mL−1 and a Nernstian slope of 35.7 mV per decade.http://dx.doi.org/10.4061/2011/643683
spellingShingle Ayman H. Kamel
Felismina T. C. Moreira
Tamara I. Silva
M. Goreti F. Sales
A Solid Binding Matrix/Mimic Receptor-Based Sensor System for Trace Level Determination of Iron Using Potential Measurements
International Journal of Electrochemistry
title A Solid Binding Matrix/Mimic Receptor-Based Sensor System for Trace Level Determination of Iron Using Potential Measurements
title_full A Solid Binding Matrix/Mimic Receptor-Based Sensor System for Trace Level Determination of Iron Using Potential Measurements
title_fullStr A Solid Binding Matrix/Mimic Receptor-Based Sensor System for Trace Level Determination of Iron Using Potential Measurements
title_full_unstemmed A Solid Binding Matrix/Mimic Receptor-Based Sensor System for Trace Level Determination of Iron Using Potential Measurements
title_short A Solid Binding Matrix/Mimic Receptor-Based Sensor System for Trace Level Determination of Iron Using Potential Measurements
title_sort solid binding matrix mimic receptor based sensor system for trace level determination of iron using potential measurements
url http://dx.doi.org/10.4061/2011/643683
work_keys_str_mv AT aymanhkamel asolidbindingmatrixmimicreceptorbasedsensorsystemfortraceleveldeterminationofironusingpotentialmeasurements
AT felisminatcmoreira asolidbindingmatrixmimicreceptorbasedsensorsystemfortraceleveldeterminationofironusingpotentialmeasurements
AT tamaraisilva asolidbindingmatrixmimicreceptorbasedsensorsystemfortraceleveldeterminationofironusingpotentialmeasurements
AT mgoretifsales asolidbindingmatrixmimicreceptorbasedsensorsystemfortraceleveldeterminationofironusingpotentialmeasurements
AT aymanhkamel solidbindingmatrixmimicreceptorbasedsensorsystemfortraceleveldeterminationofironusingpotentialmeasurements
AT felisminatcmoreira solidbindingmatrixmimicreceptorbasedsensorsystemfortraceleveldeterminationofironusingpotentialmeasurements
AT tamaraisilva solidbindingmatrixmimicreceptorbasedsensorsystemfortraceleveldeterminationofironusingpotentialmeasurements
AT mgoretifsales solidbindingmatrixmimicreceptorbasedsensorsystemfortraceleveldeterminationofironusingpotentialmeasurements