Pendelluft in Chronic Obstructive Lung Disease Measured with Lung Sounds

Objective. The phenomenon of pendelluft was described over five decades ago. In patients with regional variations in resistance and elastance, gas moves at the beginning of inspiration out of some alveoli into others. Gas moves in the opposite direction at the end of inspiration. The objective of th...

Full description

Saved in:
Bibliographic Details
Main Authors: Andrey Vyshedskiy, Raymond Murphy
Format: Article
Language:English
Published: Wiley 2012-01-01
Series:Pulmonary Medicine
Online Access:http://dx.doi.org/10.1155/2012/139395
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832551251751993344
author Andrey Vyshedskiy
Raymond Murphy
author_facet Andrey Vyshedskiy
Raymond Murphy
author_sort Andrey Vyshedskiy
collection DOAJ
description Objective. The phenomenon of pendelluft was described over five decades ago. In patients with regional variations in resistance and elastance, gas moves at the beginning of inspiration out of some alveoli into others. Gas moves in the opposite direction at the end of inspiration. The objective of this study was to apply the method of lung sounds mapping, which is known to provide regional information about gas flow, to study pendelluft in COPD patients. Methods. A 16-channel lung sound analyzer was used to collect sounds from patients with COPD (n=90) and age-matched normals (n=90). Pendelluft at the beginning of inspiration is expected to result in vesicular sounds leading the tracheal sound by a few milliseconds. Pendelluft at the end of inspiration is expected to result in vesicular sounds lagging the tracheal sound. These lead and lag times were calculated for the 14 chest wall sites. Results. The lead time was significantly longer in COPD patients: 123±107 ms versus 48±59 ms in controls (P<0.0001). The lag time was also significantly longer in COPD patients: 269±249 ms in COPD patients versus 147±124 ms in controls (P<0.0001). When normalized by the duration of the inspiration at the trachea, the lead was 14±13% for COPD versus 4±5% for controls (P<0.0001). The lag was 28±25% for COPD versus 13±12% for controls (P<0.0001). Both lead and lag correlated moderately with the GOLD stage (correlation coefficient 0.43). Conclusion. Increased lead and lag times in COPD patients are consistent with the phenomenon of pendelluft as has been observed by other methods.
format Article
id doaj-art-54dd31838a484841a3f46bbe87363ad3
institution Kabale University
issn 2090-1836
2090-1844
language English
publishDate 2012-01-01
publisher Wiley
record_format Article
series Pulmonary Medicine
spelling doaj-art-54dd31838a484841a3f46bbe87363ad32025-02-03T06:01:55ZengWileyPulmonary Medicine2090-18362090-18442012-01-01201210.1155/2012/139395139395Pendelluft in Chronic Obstructive Lung Disease Measured with Lung SoundsAndrey Vyshedskiy0Raymond Murphy1Brigham and Women's, Faulkner Hospital, Boston, MA 02130, USABrigham and Women's, Faulkner Hospital, Boston, MA 02130, USAObjective. The phenomenon of pendelluft was described over five decades ago. In patients with regional variations in resistance and elastance, gas moves at the beginning of inspiration out of some alveoli into others. Gas moves in the opposite direction at the end of inspiration. The objective of this study was to apply the method of lung sounds mapping, which is known to provide regional information about gas flow, to study pendelluft in COPD patients. Methods. A 16-channel lung sound analyzer was used to collect sounds from patients with COPD (n=90) and age-matched normals (n=90). Pendelluft at the beginning of inspiration is expected to result in vesicular sounds leading the tracheal sound by a few milliseconds. Pendelluft at the end of inspiration is expected to result in vesicular sounds lagging the tracheal sound. These lead and lag times were calculated for the 14 chest wall sites. Results. The lead time was significantly longer in COPD patients: 123±107 ms versus 48±59 ms in controls (P<0.0001). The lag time was also significantly longer in COPD patients: 269±249 ms in COPD patients versus 147±124 ms in controls (P<0.0001). When normalized by the duration of the inspiration at the trachea, the lead was 14±13% for COPD versus 4±5% for controls (P<0.0001). The lag was 28±25% for COPD versus 13±12% for controls (P<0.0001). Both lead and lag correlated moderately with the GOLD stage (correlation coefficient 0.43). Conclusion. Increased lead and lag times in COPD patients are consistent with the phenomenon of pendelluft as has been observed by other methods.http://dx.doi.org/10.1155/2012/139395
spellingShingle Andrey Vyshedskiy
Raymond Murphy
Pendelluft in Chronic Obstructive Lung Disease Measured with Lung Sounds
Pulmonary Medicine
title Pendelluft in Chronic Obstructive Lung Disease Measured with Lung Sounds
title_full Pendelluft in Chronic Obstructive Lung Disease Measured with Lung Sounds
title_fullStr Pendelluft in Chronic Obstructive Lung Disease Measured with Lung Sounds
title_full_unstemmed Pendelluft in Chronic Obstructive Lung Disease Measured with Lung Sounds
title_short Pendelluft in Chronic Obstructive Lung Disease Measured with Lung Sounds
title_sort pendelluft in chronic obstructive lung disease measured with lung sounds
url http://dx.doi.org/10.1155/2012/139395
work_keys_str_mv AT andreyvyshedskiy pendelluftinchronicobstructivelungdiseasemeasuredwithlungsounds
AT raymondmurphy pendelluftinchronicobstructivelungdiseasemeasuredwithlungsounds