Calculation of Temperature Action of Flat Steel Box Girder of Long-Span Bridges Using a Joint Model of ARMA Mean and GARCH Variance
Using the monitoring temperature field data from the flat steel box girder, the time histories of temperature data and temperature difference data are investigated using the extreme value analysis method. Because the calculation of standard values of temperature action needs massive temperature fiel...
Saved in:
Main Authors: | Jun Yang, Dacheng Zhao, Bin Chen, Gaoxin Wang |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2024-01-01
|
Series: | Shock and Vibration |
Online Access: | http://dx.doi.org/10.1155/2024/1948140 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
Research on calculation of transverse bending moment of deck of box girder with long-span and long cantilever
by: Zhaonan Wang, et al.
Published: (2025-01-01) -
Study on Sunshine Stress Effect of Long-Span and Wide Concrete Box Girder
by: Wang Cheng, et al.
Published: (2022-01-01) -
Span Length Variance Effect on the Fatigue Life of FRP Bridge Deck
by: Ki-Tae Park, et al.
Published: (2013-01-01) -
Empirical Likelihood for Partial Parameters in ARMA Models with Infinite Variance
by: Jinyu Li, et al.
Published: (2014-01-01) -
Study on the Dynamic Response of Composite Box Girder Bridges with Corrugated Steel Webs
by: Ya-Na Mao, et al.
Published: (2023-01-01)