The load inductor in the IGBT dynamic test circuit (clamped inductive circuit) works as a current source. Therefore, the load inductance is considered to have no influence on the test results. In this paper, it is found that the IGBT turn-off parameters increase with the load inductance within limit...
Saved in:
| Main Authors: | , , , , |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
Editorial Office of Control and Information Technology
2017-01-01
|
| Series: | Kongzhi Yu Xinxi Jishu |
| Subjects: | |
| Online Access: | http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2095-3631.2017.05.008 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Summary: | The load inductor in the IGBT dynamic test circuit (clamped inductive circuit) works as a current source. Therefore, the load inductance is considered to have no influence on the test results. In this paper, it is found that the IGBT turn-off parameters increase with the load inductance within limits, and this property is related to the device designs. With the analysis of device physics mechanism, it is found that the load inductance affects the voltage rise rate at turning-off, and thus affects the ratio of the hole current at turning-off. |
|---|---|