Accurate location method of branch line break fault in distribution network considering system operation mode

In the process of locating faults caused by branch line breaks in distribution networks, it is difficult to determine the range of wire breakage due to differences in fault interference branch node identification methods. The relative error of fault location results under different sampling rates is...

Full description

Saved in:
Bibliographic Details
Main Authors: XU Fei, DENG Yanzhen, LIU Honghui, WANG Hui, ZHAO Haiyang
Format: Article
Language:zho
Published: Beijing Xintong Media Co., Ltd 2024-03-01
Series:Dianxin kexue
Subjects:
Online Access:http://www.telecomsci.com/zh/article/doi/10.11959/j.issn.1000-0801.2024032/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841533891073015808
author XU Fei
DENG Yanzhen
LIU Honghui
WANG Hui
ZHAO Haiyang
author_facet XU Fei
DENG Yanzhen
LIU Honghui
WANG Hui
ZHAO Haiyang
author_sort XU Fei
collection DOAJ
description In the process of locating faults caused by branch line breaks in distribution networks, it is difficult to determine the range of wire breakage due to differences in fault interference branch node identification methods. The relative error of fault location results under different sampling rates is relatively large. Therefore, a accurate location method for branch line break faults in distribution networks considering system operation mode was proposed. The traveling wave transmission path within the power supply system was analyzed based on the topology of the distribution network. A connection matrix for branch nodes was constructed in the distribution network based on the operating mode of the power supply system. Identify the branch nodes affected by wire breakage faults and determine the scope of wire breakage occurrence. Determine the fault occurrence interval based on the characteristic parameters of wire breakage faults. By combining the time difference between zero mode traveling wave and line mode traveling wave, fault location can be obtained, achieving precise positioning of branch line breakage faults in distribution networks. The example analysis results show that after obtaining a high-precision traveling wave signal waveform, the relative error of fault localization results at different sampling rates is reduced by 48% and 12%.
format Article
id doaj-art-51d52b62919d4fb8b37291483217d886
institution Kabale University
issn 1000-0801
language zho
publishDate 2024-03-01
publisher Beijing Xintong Media Co., Ltd
record_format Article
series Dianxin kexue
spelling doaj-art-51d52b62919d4fb8b37291483217d8862025-01-15T02:48:18ZzhoBeijing Xintong Media Co., LtdDianxin kexue1000-08012024-03-014012813555075178Accurate location method of branch line break fault in distribution network considering system operation modeXU FeiDENG YanzhenLIU HonghuiWANG HuiZHAO HaiyangIn the process of locating faults caused by branch line breaks in distribution networks, it is difficult to determine the range of wire breakage due to differences in fault interference branch node identification methods. The relative error of fault location results under different sampling rates is relatively large. Therefore, a accurate location method for branch line break faults in distribution networks considering system operation mode was proposed. The traveling wave transmission path within the power supply system was analyzed based on the topology of the distribution network. A connection matrix for branch nodes was constructed in the distribution network based on the operating mode of the power supply system. Identify the branch nodes affected by wire breakage faults and determine the scope of wire breakage occurrence. Determine the fault occurrence interval based on the characteristic parameters of wire breakage faults. By combining the time difference between zero mode traveling wave and line mode traveling wave, fault location can be obtained, achieving precise positioning of branch line breakage faults in distribution networks. The example analysis results show that after obtaining a high-precision traveling wave signal waveform, the relative error of fault localization results at different sampling rates is reduced by 48% and 12%.http://www.telecomsci.com/zh/article/doi/10.11959/j.issn.1000-0801.2024032/system operation modedistribution networkbreak faultaccurate locationdisturbed equipmenttraveling wave
spellingShingle XU Fei
DENG Yanzhen
LIU Honghui
WANG Hui
ZHAO Haiyang
Accurate location method of branch line break fault in distribution network considering system operation mode
Dianxin kexue
system operation mode
distribution network
break fault
accurate location
disturbed equipment
traveling wave
title Accurate location method of branch line break fault in distribution network considering system operation mode
title_full Accurate location method of branch line break fault in distribution network considering system operation mode
title_fullStr Accurate location method of branch line break fault in distribution network considering system operation mode
title_full_unstemmed Accurate location method of branch line break fault in distribution network considering system operation mode
title_short Accurate location method of branch line break fault in distribution network considering system operation mode
title_sort accurate location method of branch line break fault in distribution network considering system operation mode
topic system operation mode
distribution network
break fault
accurate location
disturbed equipment
traveling wave
url http://www.telecomsci.com/zh/article/doi/10.11959/j.issn.1000-0801.2024032/
work_keys_str_mv AT xufei accuratelocationmethodofbranchlinebreakfaultindistributionnetworkconsideringsystemoperationmode
AT dengyanzhen accuratelocationmethodofbranchlinebreakfaultindistributionnetworkconsideringsystemoperationmode
AT liuhonghui accuratelocationmethodofbranchlinebreakfaultindistributionnetworkconsideringsystemoperationmode
AT wanghui accuratelocationmethodofbranchlinebreakfaultindistributionnetworkconsideringsystemoperationmode
AT zhaohaiyang accuratelocationmethodofbranchlinebreakfaultindistributionnetworkconsideringsystemoperationmode