Comparison of operative microscope and exoscope for execution of microanastomoses on an artificial model

IntroductionWhile the improved ergonomics, depth of field, and freedom of movement offered by Exoscopes compared to Operative Microscopes are well established, their value in surgical education and training is often mentioned but remains poorly documented.MethodsIn this study, we used a using a slig...

Full description

Saved in:
Bibliographic Details
Main Authors: T. Calloni, G. Carone, M. Cavaliere, C. de Laurentis, M. Bussa, L. Antolini, F. Nicolosi, G. G. Carrabba, M. M. Fontanella, M. Cenzato, F. DiMeco, F. Acerbi, C. G. Giussani
Format: Article
Language:English
Published: Frontiers Media S.A. 2025-08-01
Series:Frontiers in Surgery
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fsurg.2025.1573333/full
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849243121955635200
author T. Calloni
T. Calloni
G. Carone
M. Cavaliere
M. Cavaliere
C. de Laurentis
C. de Laurentis
C. de Laurentis
M. Bussa
L. Antolini
F. Nicolosi
G. G. Carrabba
G. G. Carrabba
M. M. Fontanella
M. Cenzato
F. DiMeco
F. DiMeco
F. DiMeco
F. Acerbi
F. Acerbi
F. Acerbi
C. G. Giussani
C. G. Giussani
author_facet T. Calloni
T. Calloni
G. Carone
M. Cavaliere
M. Cavaliere
C. de Laurentis
C. de Laurentis
C. de Laurentis
M. Bussa
L. Antolini
F. Nicolosi
G. G. Carrabba
G. G. Carrabba
M. M. Fontanella
M. Cenzato
F. DiMeco
F. DiMeco
F. DiMeco
F. Acerbi
F. Acerbi
F. Acerbi
C. G. Giussani
C. G. Giussani
author_sort T. Calloni
collection DOAJ
description IntroductionWhile the improved ergonomics, depth of field, and freedom of movement offered by Exoscopes compared to Operative Microscopes are well established, their value in surgical education and training is often mentioned but remains poorly documented.MethodsIn this study, we used a using a slightly modified version of the NOMAT score to compare the microvascular anastomoses on an artificial model made using traditional Operative Microscopes and the Orbeye 4K 3D Exoscope. Each participant performed the task 3 times.ResultsThe results showed that microscope users initially scored higher in several aspects, likely due to greater prior familiarity with the device. However, by the third repetition, the differences were no longer significant, demonstrating that the Exoscope is not inferior to the traditional Microscope in laboratory training. Moreover, the Exoscope group exhibited a faster learning curve for specific skills, highlighting its potential for early adoption by young surgeons.DiscussionThese findings emphasize the educational promise of Exoscopes, particularly in facilitating a smooth transition from traditional microscopes. However, further studies with larger sample sizes and extended training periods are needed to validate these conclusions.
format Article
id doaj-art-51a264a4d6f44ce49c2e95221fb26ac2
institution Kabale University
issn 2296-875X
language English
publishDate 2025-08-01
publisher Frontiers Media S.A.
record_format Article
series Frontiers in Surgery
spelling doaj-art-51a264a4d6f44ce49c2e95221fb26ac22025-08-20T03:59:36ZengFrontiers Media S.A.Frontiers in Surgery2296-875X2025-08-011210.3389/fsurg.2025.15733331573333Comparison of operative microscope and exoscope for execution of microanastomoses on an artificial modelT. Calloni0T. Calloni1G. Carone2M. Cavaliere3M. Cavaliere4C. de Laurentis5C. de Laurentis6C. de Laurentis7M. Bussa8L. Antolini9F. Nicolosi10G. G. Carrabba11G. G. Carrabba12M. M. Fontanella13M. Cenzato14F. DiMeco15F. DiMeco16F. DiMeco17F. Acerbi18F. Acerbi19F. Acerbi20C. G. Giussani21C. G. Giussani22Department of Neurosurgery, IRCCS San Gerardo dei Tintori, Monza, ItalySchool of Medicine and Surgery, University of Milano- Bicocca, Milan, ItalyDepartment of Neurosurgery, IRCCS Carlo Besta Neurological Institute Foundation, Milan, ItalySchool of Medicine and Surgery, University of Milano- Bicocca, Milan, ItalyDepartment of Neurosurgery, ASST Fatebenefratelli—Sacco, Milan, ItalySchool of Medicine and Surgery, University of Milano- Bicocca, Milan, ItalyDepartment of Neurosurgery, Groupement Hospitalier Est, Hospices Civils de Lyon, Lyon, FranceFaculté de Médecine Lyon Est, Claude Bernard University Lyon 1, Lyon, FranceSchool of Medicine and Surgery, University of Milano- Bicocca, Milan, ItalySchool of Medicine and Surgery, University of Milano- Bicocca, Milan, ItalySchool of Medicine and Surgery, University of Milano- Bicocca, Milan, ItalyDepartment of Neurosurgery, IRCCS San Gerardo dei Tintori, Monza, ItalySchool of Medicine and Surgery, University of Milano- Bicocca, Milan, ItalyDivision of Neurosurgery, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, Brecia, ItalyDepartment of Neurosurgery, Great Metropolitan Hospital Niguarda, Milan, ItalyDepartment of Neurosurgery, IRCCS Carlo Besta Neurological Institute Foundation, Milan, ItalyDepartment of Pathophysiology and Transplantation, University of Milan, Milan, Italy0Department of Neurosurgery, Johns Hopkins Medical School, Baltimore, MD, United StatesDepartment of Neurosurgery, IRCCS Carlo Besta Neurological Institute Foundation, Milan, Italy1Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy2Neurosurgery Department, Azienda Ospedaliero-Universitaria Pisana, Pisa, ItalyDepartment of Neurosurgery, IRCCS San Gerardo dei Tintori, Monza, ItalySchool of Medicine and Surgery, University of Milano- Bicocca, Milan, ItalyIntroductionWhile the improved ergonomics, depth of field, and freedom of movement offered by Exoscopes compared to Operative Microscopes are well established, their value in surgical education and training is often mentioned but remains poorly documented.MethodsIn this study, we used a using a slightly modified version of the NOMAT score to compare the microvascular anastomoses on an artificial model made using traditional Operative Microscopes and the Orbeye 4K 3D Exoscope. Each participant performed the task 3 times.ResultsThe results showed that microscope users initially scored higher in several aspects, likely due to greater prior familiarity with the device. However, by the third repetition, the differences were no longer significant, demonstrating that the Exoscope is not inferior to the traditional Microscope in laboratory training. Moreover, the Exoscope group exhibited a faster learning curve for specific skills, highlighting its potential for early adoption by young surgeons.DiscussionThese findings emphasize the educational promise of Exoscopes, particularly in facilitating a smooth transition from traditional microscopes. However, further studies with larger sample sizes and extended training periods are needed to validate these conclusions.https://www.frontiersin.org/articles/10.3389/fsurg.2025.1573333/fullmicroanastomosesmicrovascular trainingeducationresidentslearning curve3D exoscope
spellingShingle T. Calloni
T. Calloni
G. Carone
M. Cavaliere
M. Cavaliere
C. de Laurentis
C. de Laurentis
C. de Laurentis
M. Bussa
L. Antolini
F. Nicolosi
G. G. Carrabba
G. G. Carrabba
M. M. Fontanella
M. Cenzato
F. DiMeco
F. DiMeco
F. DiMeco
F. Acerbi
F. Acerbi
F. Acerbi
C. G. Giussani
C. G. Giussani
Comparison of operative microscope and exoscope for execution of microanastomoses on an artificial model
Frontiers in Surgery
microanastomoses
microvascular training
education
residents
learning curve
3D exoscope
title Comparison of operative microscope and exoscope for execution of microanastomoses on an artificial model
title_full Comparison of operative microscope and exoscope for execution of microanastomoses on an artificial model
title_fullStr Comparison of operative microscope and exoscope for execution of microanastomoses on an artificial model
title_full_unstemmed Comparison of operative microscope and exoscope for execution of microanastomoses on an artificial model
title_short Comparison of operative microscope and exoscope for execution of microanastomoses on an artificial model
title_sort comparison of operative microscope and exoscope for execution of microanastomoses on an artificial model
topic microanastomoses
microvascular training
education
residents
learning curve
3D exoscope
url https://www.frontiersin.org/articles/10.3389/fsurg.2025.1573333/full
work_keys_str_mv AT tcalloni comparisonofoperativemicroscopeandexoscopeforexecutionofmicroanastomosesonanartificialmodel
AT tcalloni comparisonofoperativemicroscopeandexoscopeforexecutionofmicroanastomosesonanartificialmodel
AT gcarone comparisonofoperativemicroscopeandexoscopeforexecutionofmicroanastomosesonanartificialmodel
AT mcavaliere comparisonofoperativemicroscopeandexoscopeforexecutionofmicroanastomosesonanartificialmodel
AT mcavaliere comparisonofoperativemicroscopeandexoscopeforexecutionofmicroanastomosesonanartificialmodel
AT cdelaurentis comparisonofoperativemicroscopeandexoscopeforexecutionofmicroanastomosesonanartificialmodel
AT cdelaurentis comparisonofoperativemicroscopeandexoscopeforexecutionofmicroanastomosesonanartificialmodel
AT cdelaurentis comparisonofoperativemicroscopeandexoscopeforexecutionofmicroanastomosesonanartificialmodel
AT mbussa comparisonofoperativemicroscopeandexoscopeforexecutionofmicroanastomosesonanartificialmodel
AT lantolini comparisonofoperativemicroscopeandexoscopeforexecutionofmicroanastomosesonanartificialmodel
AT fnicolosi comparisonofoperativemicroscopeandexoscopeforexecutionofmicroanastomosesonanartificialmodel
AT ggcarrabba comparisonofoperativemicroscopeandexoscopeforexecutionofmicroanastomosesonanartificialmodel
AT ggcarrabba comparisonofoperativemicroscopeandexoscopeforexecutionofmicroanastomosesonanartificialmodel
AT mmfontanella comparisonofoperativemicroscopeandexoscopeforexecutionofmicroanastomosesonanartificialmodel
AT mcenzato comparisonofoperativemicroscopeandexoscopeforexecutionofmicroanastomosesonanartificialmodel
AT fdimeco comparisonofoperativemicroscopeandexoscopeforexecutionofmicroanastomosesonanartificialmodel
AT fdimeco comparisonofoperativemicroscopeandexoscopeforexecutionofmicroanastomosesonanartificialmodel
AT fdimeco comparisonofoperativemicroscopeandexoscopeforexecutionofmicroanastomosesonanartificialmodel
AT facerbi comparisonofoperativemicroscopeandexoscopeforexecutionofmicroanastomosesonanartificialmodel
AT facerbi comparisonofoperativemicroscopeandexoscopeforexecutionofmicroanastomosesonanartificialmodel
AT facerbi comparisonofoperativemicroscopeandexoscopeforexecutionofmicroanastomosesonanartificialmodel
AT cggiussani comparisonofoperativemicroscopeandexoscopeforexecutionofmicroanastomosesonanartificialmodel
AT cggiussani comparisonofoperativemicroscopeandexoscopeforexecutionofmicroanastomosesonanartificialmodel