The Improved Measurement of Building Thermal Transmittance in Zagreb Using a Temperature-Based Method
Theoretical <i>U</i>-values, which measure thermal transmittance, can be calculated based on the thermal parameters of an opaque element’s layers. However, practical measurements are essential to validate these theoretical values. The heat flux meter (HFM) method, is a widely accepted st...
Saved in:
| Main Authors: | Igor Štambuk, Roman Malarić, Ivica Bakota, Zvonko Trzun |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
MDPI AG
2025-05-01
|
| Series: | Sensors |
| Subjects: | |
| Online Access: | https://www.mdpi.com/1424-8220/25/11/3456 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
Influence of Boundary Conditions on the Estimation of Thermal Properties in Insulated Building Walls
by: Manon Rendu, et al.
Published: (2024-11-01) -
Thermal performance assessment of opaque ventilated façades for residential buildings in hot humid climates
by: Fulya Gökşen, et al.
Published: (2023-01-01) -
Processing Water‐Medium Spinal Endoscopic Images Based on Dual Transmittance
by: Ning Hu, et al.
Published: (2025-06-01) -
Biomimetic Opaque Ventilated Façade for Low-Rise Buildings in Hot Arid Climate
by: Ahmed Alyahya, et al.
Published: (2025-07-01) -
An automatic VHF transmitter monitoring system for wildlife research
by: A. Torbjörn Johansson, et al.
Published: (2011-12-01)