Design of LC Filter with Shunt Damping Resistor for Non-linear Load to Reduce the Total Harmonic Distortion in Load Voltage

The electrical power distribution system is the part of a power system, which supplies electrical power to consumers for utilization. Recently the utilization of nonlinear loads has been increasing in distribution system which badly affected the sinusoidal output voltage waveform. Every consumer of...

Full description

Saved in:
Bibliographic Details
Main Authors: Abdul Hameed soomro, Iqrar Ahmed Khoso, Naseeb Ullah Sawand, Lal Bux Nuhrio
Format: Article
Language:English
Published: Sir Syed University of Engineering and Technology, Karachi. 2024-05-01
Series:Sir Syed University Research Journal of Engineering and Technology
Subjects:
Online Access:http://www.sirsyeduniversity.edu.pk/ssurj/rj/index.php/ssurj/article/view/612
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849434262264086528
author Abdul Hameed soomro
Iqrar Ahmed Khoso
Naseeb Ullah Sawand
Lal Bux Nuhrio
author_facet Abdul Hameed soomro
Iqrar Ahmed Khoso
Naseeb Ullah Sawand
Lal Bux Nuhrio
author_sort Abdul Hameed soomro
collection DOAJ
description The electrical power distribution system is the part of a power system, which supplies electrical power to consumers for utilization. Recently the utilization of nonlinear loads has been increasing in distribution system which badly affected the sinusoidal output voltage waveform. Every consumer of electricity demand consistent and sinusoidal voltage waveform to run their loads properly but due to power quality issues such as harmonics, voltage sag, voltage swell, flickering, and interruption of power supply which badly affect the output voltage of the loads may result in equipment damages, and financial loss. This research study discusses the voltage harmonic which is one of the power quality problems. The harmonic is a Non sinusoidal waveform that is generated due to the applications of nonlinear loads which affect the power system reliability, increase the transformer losses, line losses,  and frequent faults are generated which results in poor utility revenue, and reduction in production in industries. So, in this research study, the LC filter with a damping resistor is designed to improve the output voltage waveform. The MATLAB simulation model is developed to analyze the performance of the distribution system under linear and nonlinear loads with and without an LC filter circuit and also THD% is analyzed through FFT.
format Article
id doaj-art-512e245c840546a59915214f2f55d80d
institution Kabale University
issn 1997-0641
2415-2048
language English
publishDate 2024-05-01
publisher Sir Syed University of Engineering and Technology, Karachi.
record_format Article
series Sir Syed University Research Journal of Engineering and Technology
spelling doaj-art-512e245c840546a59915214f2f55d80d2025-08-20T03:26:43ZengSir Syed University of Engineering and Technology, Karachi.Sir Syed University Research Journal of Engineering and Technology1997-06412415-20482024-05-0114110.33317/ssurj.612Design of LC Filter with Shunt Damping Resistor for Non-linear Load to Reduce the Total Harmonic Distortion in Load Voltage Abdul Hameed soomro0Iqrar Ahmed KhosoNaseeb Ullah SawandLal Bux NuhrioQuai-e-Awam University Nawabshah Campus Larkano The electrical power distribution system is the part of a power system, which supplies electrical power to consumers for utilization. Recently the utilization of nonlinear loads has been increasing in distribution system which badly affected the sinusoidal output voltage waveform. Every consumer of electricity demand consistent and sinusoidal voltage waveform to run their loads properly but due to power quality issues such as harmonics, voltage sag, voltage swell, flickering, and interruption of power supply which badly affect the output voltage of the loads may result in equipment damages, and financial loss. This research study discusses the voltage harmonic which is one of the power quality problems. The harmonic is a Non sinusoidal waveform that is generated due to the applications of nonlinear loads which affect the power system reliability, increase the transformer losses, line losses,  and frequent faults are generated which results in poor utility revenue, and reduction in production in industries. So, in this research study, the LC filter with a damping resistor is designed to improve the output voltage waveform. The MATLAB simulation model is developed to analyze the performance of the distribution system under linear and nonlinear loads with and without an LC filter circuit and also THD% is analyzed through FFT. http://www.sirsyeduniversity.edu.pk/ssurj/rj/index.php/ssurj/article/view/612Fast Fourier TransformLC Filter Power Quality issues Total Harmonic DistortionNon-linear load
spellingShingle Abdul Hameed soomro
Iqrar Ahmed Khoso
Naseeb Ullah Sawand
Lal Bux Nuhrio
Design of LC Filter with Shunt Damping Resistor for Non-linear Load to Reduce the Total Harmonic Distortion in Load Voltage
Sir Syed University Research Journal of Engineering and Technology
Fast Fourier Transform
LC Filter
Power Quality issues
Total Harmonic Distortion
Non-linear load
title Design of LC Filter with Shunt Damping Resistor for Non-linear Load to Reduce the Total Harmonic Distortion in Load Voltage
title_full Design of LC Filter with Shunt Damping Resistor for Non-linear Load to Reduce the Total Harmonic Distortion in Load Voltage
title_fullStr Design of LC Filter with Shunt Damping Resistor for Non-linear Load to Reduce the Total Harmonic Distortion in Load Voltage
title_full_unstemmed Design of LC Filter with Shunt Damping Resistor for Non-linear Load to Reduce the Total Harmonic Distortion in Load Voltage
title_short Design of LC Filter with Shunt Damping Resistor for Non-linear Load to Reduce the Total Harmonic Distortion in Load Voltage
title_sort design of lc filter with shunt damping resistor for non linear load to reduce the total harmonic distortion in load voltage
topic Fast Fourier Transform
LC Filter
Power Quality issues
Total Harmonic Distortion
Non-linear load
url http://www.sirsyeduniversity.edu.pk/ssurj/rj/index.php/ssurj/article/view/612
work_keys_str_mv AT abdulhameedsoomro designoflcfilterwithshuntdampingresistorfornonlinearloadtoreducethetotalharmonicdistortioninloadvoltage
AT iqrarahmedkhoso designoflcfilterwithshuntdampingresistorfornonlinearloadtoreducethetotalharmonicdistortioninloadvoltage
AT naseebullahsawand designoflcfilterwithshuntdampingresistorfornonlinearloadtoreducethetotalharmonicdistortioninloadvoltage
AT lalbuxnuhrio designoflcfilterwithshuntdampingresistorfornonlinearloadtoreducethetotalharmonicdistortioninloadvoltage