Examining the Existing Criteria for the Evaluation of Window Ejected Plume Attachment

Both single-skin and double-skin glass facades are extensively employed in commercial high-rise buildings and are gaining increasing popularity. However, the capability to deploy firefighting agents in such ultra-high structures remains limited and has been minimally investigated. To provide guidanc...

Full description

Saved in:
Bibliographic Details
Main Authors: Jianlong Xing, Chaoting Nie, Bin Zheng, Lei Miao
Format: Article
Language:English
Published: MDPI AG 2025-04-01
Series:Fire
Subjects:
Online Access:https://www.mdpi.com/2571-6255/8/5/168
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Both single-skin and double-skin glass facades are extensively employed in commercial high-rise buildings and are gaining increasing popularity. However, the capability to deploy firefighting agents in such ultra-high structures remains limited and has been minimally investigated. To provide guidance for single-layer exterior wall fire protection, this study examines the impact of vertical walls on window ejected plumes by simulating the upper portion of jet plumes using a square burner flame. Experimental and numerical simulations were conducted. The findings revealed that plumes from propane burners could attach to the wall even when <i>L</i><sub>E. burner fire</sub> > 0.7<i>W</i>, contradicting previous criteria. This discrepancy arises because prior studies underestimated the induced pressure difference in large fires. This pressure difference propels the plume toward the wall, behaving like a rigid body.
ISSN:2571-6255