Experimental demonstration of dark current mitigation by an over-inserted plug in a normal conducting very-high-frequency gun
The room temperature continuous wave (cw) very-high-frequency (VHF) gun is one of the candidates for the electron gun of the high-repetition-rate free-electron lasers (FELs). The VHF gun operates with a cathode gradient of ∼20 MV/m and an accelerating voltage of ∼750 kV. The gun dark current emiss...
Saved in:
| Main Authors: | Xing-Heng Wang, Guan Shu, Hou-Jun Qian, Xu-Dong Li, Zi-Peng Liu, Zeng-Gong Jiang, Hao Meng, Cao-Cao Xing, Qin Zhou, Hai-Xiao Deng |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
American Physical Society
2025-04-01
|
| Series: | Physical Review Accelerators and Beams |
| Online Access: | http://doi.org/10.1103/PhysRevAccelBeams.28.043401 |