Investigation of the effect of coagulation with high-energy methods of hemostasis implementation on the resected liver surface (experimental research).

The peculiarity of using high-energy methods to implement hemostasis is in difficulty of comparing the degree of exposure to high temperature with the achievement of the desired effect, at the same time, excessive temperature in the area of impact leads to the formation of a layer of carbonized tiss...

Full description

Saved in:
Bibliographic Details
Main Author: O. P. Ternavskyi
Format: Article
Language:English
Published: Dnipro State Medical University 2018-11-01
Series:Medičnì Perspektivi
Subjects:
Online Access:http://journals.uran.ua/index.php/2307-0404/article/view/147961
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850215573599813632
author O. P. Ternavskyi
author_facet O. P. Ternavskyi
author_sort O. P. Ternavskyi
collection DOAJ
description The peculiarity of using high-energy methods to implement hemostasis is in difficulty of comparing the degree of exposure to high temperature with the achievement of the desired effect, at the same time, excessive temperature in the area of impact leads to the formation of a layer of carbonized tissues or their evaporation. In order to analyze the peculiarities of changes in the liver parenchyma after coagulation with high-energy methods of hemostasis, an experiment that provided liver resection with coagulation of the resection surface using convection-infrared thermosurgical technology in a temperature mode of 600°C, bipolar electro-coagulation and high-frequency electric welding of living biological tissues was performed. The study analyzed the results of experimental studies on 25 outbred rabbits of different sex and age, weighing from 3350.0 g to 4180.0 g. Depending on the use of the high-energy coagulation method, 3 groups were formed: group 1 - high-frequency electric welding of living biological tissues; group 2 - bipolar electro-coagulation; group 3 - convection-infrared thermo­surgical technology at a temperature mode of 600°C. The data of histological research were analysed. Statistical analysis was performed using SPSS Statistics. Studies have found that the average trend of the thickness of the disaggregation/disintegration zone is 1936 (1630.83-2523) μm in the 1st group, 648 (508.33-734.33) μm in the 2nd group and 470.6 (453.5-507) μm in the 3rd group. The zone of compacted parenchyma: the 1st group – 2732 (2591.5-2798.5) μm, the second group 4538 (4421.5-4687.5) μm (p=0.001). The results of the study indicate that the use of convection-infrared thermosurgical technology in a temperature mode of 600°C has a less destructive effect on the surrounding tissues as compared with bipolar electrocoagulation and high-frequency electric welding of biological tissues.
format Article
id doaj-art-50775e8e825247f0bfcd4f300a0d93a2
institution OA Journals
issn 2307-0404
language English
publishDate 2018-11-01
publisher Dnipro State Medical University
record_format Article
series Medičnì Perspektivi
spelling doaj-art-50775e8e825247f0bfcd4f300a0d93a22025-08-20T02:08:35ZengDnipro State Medical UniversityMedičnì Perspektivi2307-04042018-11-01233788310.26641/2307-0404.2018.3.147961147961Investigation of the effect of coagulation with high-energy methods of hemostasis implementation on the resected liver surface (experimental research).O. P. TernavskyiThe peculiarity of using high-energy methods to implement hemostasis is in difficulty of comparing the degree of exposure to high temperature with the achievement of the desired effect, at the same time, excessive temperature in the area of impact leads to the formation of a layer of carbonized tissues or their evaporation. In order to analyze the peculiarities of changes in the liver parenchyma after coagulation with high-energy methods of hemostasis, an experiment that provided liver resection with coagulation of the resection surface using convection-infrared thermosurgical technology in a temperature mode of 600°C, bipolar electro-coagulation and high-frequency electric welding of living biological tissues was performed. The study analyzed the results of experimental studies on 25 outbred rabbits of different sex and age, weighing from 3350.0 g to 4180.0 g. Depending on the use of the high-energy coagulation method, 3 groups were formed: group 1 - high-frequency electric welding of living biological tissues; group 2 - bipolar electro-coagulation; group 3 - convection-infrared thermo­surgical technology at a temperature mode of 600°C. The data of histological research were analysed. Statistical analysis was performed using SPSS Statistics. Studies have found that the average trend of the thickness of the disaggregation/disintegration zone is 1936 (1630.83-2523) μm in the 1st group, 648 (508.33-734.33) μm in the 2nd group and 470.6 (453.5-507) μm in the 3rd group. The zone of compacted parenchyma: the 1st group – 2732 (2591.5-2798.5) μm, the second group 4538 (4421.5-4687.5) μm (p=0.001). The results of the study indicate that the use of convection-infrared thermosurgical technology in a temperature mode of 600°C has a less destructive effect on the surrounding tissues as compared with bipolar electrocoagulation and high-frequency electric welding of biological tissues.http://journals.uran.ua/index.php/2307-0404/article/view/147961convection-infrared thermosurgical technologycoagulation hemostasisbipolar electrocoagulationhigh-frequency electric welding of living biological tissuescoagulation zoneliver parenchymaexperiment
spellingShingle O. P. Ternavskyi
Investigation of the effect of coagulation with high-energy methods of hemostasis implementation on the resected liver surface (experimental research).
Medičnì Perspektivi
convection-infrared thermosurgical technology
coagulation hemostasis
bipolar electrocoagulation
high-frequency electric welding of living biological tissues
coagulation zone
liver parenchyma
experiment
title Investigation of the effect of coagulation with high-energy methods of hemostasis implementation on the resected liver surface (experimental research).
title_full Investigation of the effect of coagulation with high-energy methods of hemostasis implementation on the resected liver surface (experimental research).
title_fullStr Investigation of the effect of coagulation with high-energy methods of hemostasis implementation on the resected liver surface (experimental research).
title_full_unstemmed Investigation of the effect of coagulation with high-energy methods of hemostasis implementation on the resected liver surface (experimental research).
title_short Investigation of the effect of coagulation with high-energy methods of hemostasis implementation on the resected liver surface (experimental research).
title_sort investigation of the effect of coagulation with high energy methods of hemostasis implementation on the resected liver surface experimental research
topic convection-infrared thermosurgical technology
coagulation hemostasis
bipolar electrocoagulation
high-frequency electric welding of living biological tissues
coagulation zone
liver parenchyma
experiment
url http://journals.uran.ua/index.php/2307-0404/article/view/147961
work_keys_str_mv AT opternavskyi investigationoftheeffectofcoagulationwithhighenergymethodsofhemostasisimplementationontheresectedliversurfaceexperimentalresearch