Analysis of Energy Performance on Envelope Ratio Exposed to the Outdoor
The shape of a building largely contributes to its energy consumption. The current study utilized metrics of surface-to-volume ratio, surface-to-floor ratio, area-to-perimeter ratio, and volume ratio to evaluate building energy performance. Also, the paper focused on the relation between the air-con...
Saved in:
| Main Authors: | , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Wiley
2018-01-01
|
| Series: | Advances in Civil Engineering |
| Online Access: | http://dx.doi.org/10.1155/2018/7483619 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850225608834940928 |
|---|---|
| author | Hong Soo Lim Gon Kim |
| author_facet | Hong Soo Lim Gon Kim |
| author_sort | Hong Soo Lim |
| collection | DOAJ |
| description | The shape of a building largely contributes to its energy consumption. The current study utilized metrics of surface-to-volume ratio, surface-to-floor ratio, area-to-perimeter ratio, and volume ratio to evaluate building energy performance. Also, the paper focused on the relation between the air-conditioned room and non-air-conditioned room. This approach affects both the design stages of the floor plan and the main designing factors that decide which spaces would become air-conditioned spaces such as those mostly occupied by residents or non-air-conditioned space such as staircases and elevators. The heating load and cooling load were calculated using the new equation based on the location of non-air-conditioned spaces and envelope ratio facing the outdoor. Both the width-depth ratio and envelope ratio were analyzed using the IES_V.E (Integrated Environmental Solutions Virtue Environment) program. It turns out that, as the non-air-conditioned spaces increase, both heating load and cooling load were reduced. |
| format | Article |
| id | doaj-art-506d33eb457d4d99a159754d6db349fe |
| institution | OA Journals |
| issn | 1687-8086 1687-8094 |
| language | English |
| publishDate | 2018-01-01 |
| publisher | Wiley |
| record_format | Article |
| series | Advances in Civil Engineering |
| spelling | doaj-art-506d33eb457d4d99a159754d6db349fe2025-08-20T02:05:18ZengWileyAdvances in Civil Engineering1687-80861687-80942018-01-01201810.1155/2018/74836197483619Analysis of Energy Performance on Envelope Ratio Exposed to the OutdoorHong Soo Lim0Gon Kim1Department of Architectural Engineering, Kyung Hee University, Yongin 446-701, Republic of KoreaDepartment of Architectural Engineering, Kyung Hee University, Yongin 446-701, Republic of KoreaThe shape of a building largely contributes to its energy consumption. The current study utilized metrics of surface-to-volume ratio, surface-to-floor ratio, area-to-perimeter ratio, and volume ratio to evaluate building energy performance. Also, the paper focused on the relation between the air-conditioned room and non-air-conditioned room. This approach affects both the design stages of the floor plan and the main designing factors that decide which spaces would become air-conditioned spaces such as those mostly occupied by residents or non-air-conditioned space such as staircases and elevators. The heating load and cooling load were calculated using the new equation based on the location of non-air-conditioned spaces and envelope ratio facing the outdoor. Both the width-depth ratio and envelope ratio were analyzed using the IES_V.E (Integrated Environmental Solutions Virtue Environment) program. It turns out that, as the non-air-conditioned spaces increase, both heating load and cooling load were reduced.http://dx.doi.org/10.1155/2018/7483619 |
| spellingShingle | Hong Soo Lim Gon Kim Analysis of Energy Performance on Envelope Ratio Exposed to the Outdoor Advances in Civil Engineering |
| title | Analysis of Energy Performance on Envelope Ratio Exposed to the Outdoor |
| title_full | Analysis of Energy Performance on Envelope Ratio Exposed to the Outdoor |
| title_fullStr | Analysis of Energy Performance on Envelope Ratio Exposed to the Outdoor |
| title_full_unstemmed | Analysis of Energy Performance on Envelope Ratio Exposed to the Outdoor |
| title_short | Analysis of Energy Performance on Envelope Ratio Exposed to the Outdoor |
| title_sort | analysis of energy performance on envelope ratio exposed to the outdoor |
| url | http://dx.doi.org/10.1155/2018/7483619 |
| work_keys_str_mv | AT hongsoolim analysisofenergyperformanceonenveloperatioexposedtotheoutdoor AT gonkim analysisofenergyperformanceonenveloperatioexposedtotheoutdoor |