POLARIZATION HYSTERESIS CURVE MEASUREMENT FOR AN Au/PZT/YBCO DEVICE BY DOUBLE PULSE TECHNIQUE

Polarization for Au/Pb(Zr Ti )O /YBa Cu O ferroelectric capacitor has been studied and measured by pulse method. A sequence of pulses with amplitudes varying from 0 to 10 volts in 2 volt steps is applied and a conventional polarization curve is obtained by integrating the charge flow from the pola...

Full description

Saved in:
Bibliographic Details
Format: Article
Language:English
Published: University of Tehran 1998-06-01
Series:Journal of Sciences, Islamic Republic of Iran
Online Access:https://jsciences.ut.ac.ir/article_31475_21b9a45c45f89fee48e83a8e01a50590.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849730781130260480
collection DOAJ
description Polarization for Au/Pb(Zr Ti )O /YBa Cu O ferroelectric capacitor has been studied and measured by pulse method. A sequence of pulses with amplitudes varying from 0 to 10 volts in 2 volt steps is applied and a conventional polarization curve is obtained by integrating the charge flow from the polarization switching induced by the voltage ramp. A value of 25?C/cm2 is measured for the saturated polarization from the hysteresis curve. The polarization retention is also measured at 200°C for the device and the polarization change over 24 hours was about 5.7%.
format Article
id doaj-art-4fff2f3e92d5460ba9da3cc266b9a03c
institution DOAJ
issn 1016-1104
2345-6914
language English
publishDate 1998-06-01
publisher University of Tehran
record_format Article
series Journal of Sciences, Islamic Republic of Iran
spelling doaj-art-4fff2f3e92d5460ba9da3cc266b9a03c2025-08-20T03:08:46ZengUniversity of TehranJournal of Sciences, Islamic Republic of Iran1016-11042345-69141998-06-019231475POLARIZATION HYSTERESIS CURVE MEASUREMENT FOR AN Au/PZT/YBCO DEVICE BY DOUBLE PULSE TECHNIQUEPolarization for Au/Pb(Zr Ti )O /YBa Cu O ferroelectric capacitor has been studied and measured by pulse method. A sequence of pulses with amplitudes varying from 0 to 10 volts in 2 volt steps is applied and a conventional polarization curve is obtained by integrating the charge flow from the polarization switching induced by the voltage ramp. A value of 25?C/cm2 is measured for the saturated polarization from the hysteresis curve. The polarization retention is also measured at 200°C for the device and the polarization change over 24 hours was about 5.7%.https://jsciences.ut.ac.ir/article_31475_21b9a45c45f89fee48e83a8e01a50590.pdf
spellingShingle POLARIZATION HYSTERESIS CURVE MEASUREMENT FOR AN Au/PZT/YBCO DEVICE BY DOUBLE PULSE TECHNIQUE
Journal of Sciences, Islamic Republic of Iran
title POLARIZATION HYSTERESIS CURVE MEASUREMENT FOR AN Au/PZT/YBCO DEVICE BY DOUBLE PULSE TECHNIQUE
title_full POLARIZATION HYSTERESIS CURVE MEASUREMENT FOR AN Au/PZT/YBCO DEVICE BY DOUBLE PULSE TECHNIQUE
title_fullStr POLARIZATION HYSTERESIS CURVE MEASUREMENT FOR AN Au/PZT/YBCO DEVICE BY DOUBLE PULSE TECHNIQUE
title_full_unstemmed POLARIZATION HYSTERESIS CURVE MEASUREMENT FOR AN Au/PZT/YBCO DEVICE BY DOUBLE PULSE TECHNIQUE
title_short POLARIZATION HYSTERESIS CURVE MEASUREMENT FOR AN Au/PZT/YBCO DEVICE BY DOUBLE PULSE TECHNIQUE
title_sort polarization hysteresis curve measurement for an au pzt ybco device by double pulse technique
url https://jsciences.ut.ac.ir/article_31475_21b9a45c45f89fee48e83a8e01a50590.pdf