The effect of evaluation of dry weight using bioimpedance method on residual renal function in maintenance hemodialysis patients
Objective To evaluate the dry weight of maintenance hemodialysis(MHD) patients using bioimpedance method and to observe the protective effect of the accurate evaluation of dry weight on residual renal function in patients with MHD. Methods Forty patients with MHD were enrolled, whose 24-hour urinary...
Saved in:
| Main Authors: | , , , , , , |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
Editorial Department of Journal of Clinical Nephrology
2019-01-01
|
| Series: | Linchuang shenzangbing zazhi |
| Subjects: | |
| Online Access: | http://www.lcszb.com/thesisDetails?columnId=57912365&Fpath=home&index=0 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850143286440755200 |
|---|---|
| author | YANG Fan LIU Xiao-jing JIN Li-qin YUAN Dan JIAO Jian CAO Qian-ying LI Zhong-xin |
| author_facet | YANG Fan LIU Xiao-jing JIN Li-qin YUAN Dan JIAO Jian CAO Qian-ying LI Zhong-xin |
| author_sort | YANG Fan |
| collection | DOAJ |
| description | Objective To evaluate the dry weight of maintenance hemodialysis(MHD) patients using bioimpedance method and to observe the protective effect of the accurate evaluation of dry weight on residual renal function in patients with MHD. Methods Forty patients with MHD were enrolled, whose 24-hour urinary volumes were ≥400 mL. They were randomly divided into the trial group and control group. The dry weight in the trial group was determined with a bioimpedance analyzer, and the dry weight in the control group was evaluated clinically. After 4 months of follow-up, the 24-hour urine volume, body weight, mean arterial pressure, dialysis ultrafiltration volume, percentage of weight gain during inter-dialysis, BNP, EF value of colorful ECG, left ventricular mass index, and dialysis-related acute complications were compared between theirbaselines and values at the last follow-up. Results Thetrial group had lower mean arterial pressure \[(92.0±9.3) vs(96.5±8.5), P<0.05\], lower BNP \[(280.3±410.5) vs(471.7±786.0), P<0.05\], and higher 24-hour urine volume \[(649.2±289.3) vs(562.5±224.8),P<0.05\] than the control group. Conclusions The application of bioimpedance technology in accurately assessing dry weight can delay the urine reduction caused by excessive ultrafiltration,has a protective effect on residual renal function, and can improve mean arterial pressure at the same time. Increasing the frequency of detection may further reduce dialysis-related complications. |
| format | Article |
| id | doaj-art-4fbfcf1f4a5d4e46ac753a416f9de080 |
| institution | OA Journals |
| issn | 1671-2390 |
| language | zho |
| publishDate | 2019-01-01 |
| publisher | Editorial Department of Journal of Clinical Nephrology |
| record_format | Article |
| series | Linchuang shenzangbing zazhi |
| spelling | doaj-art-4fbfcf1f4a5d4e46ac753a416f9de0802025-08-20T02:28:46ZzhoEditorial Department of Journal of Clinical NephrologyLinchuang shenzangbing zazhi1671-23902019-01-0134735157912365The effect of evaluation of dry weight using bioimpedance method on residual renal function in maintenance hemodialysis patientsYANG FanLIU Xiao-jingJIN Li-qinYUAN DanJIAO JianCAO Qian-yingLI Zhong-xinObjective To evaluate the dry weight of maintenance hemodialysis(MHD) patients using bioimpedance method and to observe the protective effect of the accurate evaluation of dry weight on residual renal function in patients with MHD. Methods Forty patients with MHD were enrolled, whose 24-hour urinary volumes were ≥400 mL. They were randomly divided into the trial group and control group. The dry weight in the trial group was determined with a bioimpedance analyzer, and the dry weight in the control group was evaluated clinically. After 4 months of follow-up, the 24-hour urine volume, body weight, mean arterial pressure, dialysis ultrafiltration volume, percentage of weight gain during inter-dialysis, BNP, EF value of colorful ECG, left ventricular mass index, and dialysis-related acute complications were compared between theirbaselines and values at the last follow-up. Results Thetrial group had lower mean arterial pressure \[(92.0±9.3) vs(96.5±8.5), P<0.05\], lower BNP \[(280.3±410.5) vs(471.7±786.0), P<0.05\], and higher 24-hour urine volume \[(649.2±289.3) vs(562.5±224.8),P<0.05\] than the control group. Conclusions The application of bioimpedance technology in accurately assessing dry weight can delay the urine reduction caused by excessive ultrafiltration,has a protective effect on residual renal function, and can improve mean arterial pressure at the same time. Increasing the frequency of detection may further reduce dialysis-related complications.http://www.lcszb.com/thesisDetails?columnId=57912365&Fpath=home&index=0Bioelectrical impedance analysisDry weightHemodialysisResidual renal function |
| spellingShingle | YANG Fan LIU Xiao-jing JIN Li-qin YUAN Dan JIAO Jian CAO Qian-ying LI Zhong-xin The effect of evaluation of dry weight using bioimpedance method on residual renal function in maintenance hemodialysis patients Linchuang shenzangbing zazhi Bioelectrical impedance analysis Dry weight Hemodialysis Residual renal function |
| title | The effect of evaluation of dry weight using bioimpedance method on residual renal function in maintenance hemodialysis patients |
| title_full | The effect of evaluation of dry weight using bioimpedance method on residual renal function in maintenance hemodialysis patients |
| title_fullStr | The effect of evaluation of dry weight using bioimpedance method on residual renal function in maintenance hemodialysis patients |
| title_full_unstemmed | The effect of evaluation of dry weight using bioimpedance method on residual renal function in maintenance hemodialysis patients |
| title_short | The effect of evaluation of dry weight using bioimpedance method on residual renal function in maintenance hemodialysis patients |
| title_sort | effect of evaluation of dry weight using bioimpedance method on residual renal function in maintenance hemodialysis patients |
| topic | Bioelectrical impedance analysis Dry weight Hemodialysis Residual renal function |
| url | http://www.lcszb.com/thesisDetails?columnId=57912365&Fpath=home&index=0 |
| work_keys_str_mv | AT yangfan theeffectofevaluationofdryweightusingbioimpedancemethodonresidualrenalfunctioninmaintenancehemodialysispatients AT liuxiaojing theeffectofevaluationofdryweightusingbioimpedancemethodonresidualrenalfunctioninmaintenancehemodialysispatients AT jinliqin theeffectofevaluationofdryweightusingbioimpedancemethodonresidualrenalfunctioninmaintenancehemodialysispatients AT yuandan theeffectofevaluationofdryweightusingbioimpedancemethodonresidualrenalfunctioninmaintenancehemodialysispatients AT jiaojian theeffectofevaluationofdryweightusingbioimpedancemethodonresidualrenalfunctioninmaintenancehemodialysispatients AT caoqianying theeffectofevaluationofdryweightusingbioimpedancemethodonresidualrenalfunctioninmaintenancehemodialysispatients AT lizhongxin theeffectofevaluationofdryweightusingbioimpedancemethodonresidualrenalfunctioninmaintenancehemodialysispatients AT yangfan effectofevaluationofdryweightusingbioimpedancemethodonresidualrenalfunctioninmaintenancehemodialysispatients AT liuxiaojing effectofevaluationofdryweightusingbioimpedancemethodonresidualrenalfunctioninmaintenancehemodialysispatients AT jinliqin effectofevaluationofdryweightusingbioimpedancemethodonresidualrenalfunctioninmaintenancehemodialysispatients AT yuandan effectofevaluationofdryweightusingbioimpedancemethodonresidualrenalfunctioninmaintenancehemodialysispatients AT jiaojian effectofevaluationofdryweightusingbioimpedancemethodonresidualrenalfunctioninmaintenancehemodialysispatients AT caoqianying effectofevaluationofdryweightusingbioimpedancemethodonresidualrenalfunctioninmaintenancehemodialysispatients AT lizhongxin effectofevaluationofdryweightusingbioimpedancemethodonresidualrenalfunctioninmaintenancehemodialysispatients |