Correlation between T-Wave Alternans and Cardiac Volume Status via Intrathoracic Impedance Measurements

Introduction. The presence of T-wave alternans (TWA) has been shown to correlate with a higher risk for sudden cardiac death. The mechanism of TWA may be related to abnormalities in intracellular calcium handling, which is a mechanism in heart failure and associated arrhythmias as well. However, a...

Full description

Saved in:
Bibliographic Details
Main Authors: Jose' Dizon, Kathleen Hickey, Hasan Garan
Format: Article
Language:English
Published: Wiley 2012-01-01
Series:Case Reports in Cardiology
Online Access:http://dx.doi.org/10.1155/2012/167562
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832562468140875776
author Jose' Dizon
Kathleen Hickey
Hasan Garan
author_facet Jose' Dizon
Kathleen Hickey
Hasan Garan
author_sort Jose' Dizon
collection DOAJ
description Introduction. The presence of T-wave alternans (TWA) has been shown to correlate with a higher risk for sudden cardiac death. The mechanism of TWA may be related to abnormalities in intracellular calcium handling, which is a mechanism in heart failure and associated arrhythmias as well. However, an association between TWA and cardiac volume status has not been demonstrated. Methods Used. We report the case of a 54-year-old man with a dilated cardiomyopathy who had a biventricular defibrillator system implanted with intrathoracic impedance measurement capability. We performed baseline TWA testing, which was normal and was associated with normal clinical status and normal intrathoracic impedance. We followed intrathoracic impedance measurements, and when the measurement suggested volume overload eight months later, we repeated the TWA test. TWA was grossly positive, and volume overload was corroborated with clinical heart failure. The patient was diuresed, and when clinical status and intrathoracic impedance returned to normal a month later, we repeated TWA, which was again negative. Conclusion. This case demonstrates a correlation between cardiac volume status, as measured by intrathoracic impedance measurements, and TWA status. This data suggests that conditions of volume overload such as heart failure could be causally related to increased TWA, perhaps by the common mechanism of altered intracellular calcium handling.
format Article
id doaj-art-4f74892989d94e7f935e70b91c01e46c
institution Kabale University
issn 2090-6404
2090-6412
language English
publishDate 2012-01-01
publisher Wiley
record_format Article
series Case Reports in Cardiology
spelling doaj-art-4f74892989d94e7f935e70b91c01e46c2025-02-03T01:22:34ZengWileyCase Reports in Cardiology2090-64042090-64122012-01-01201210.1155/2012/167562167562Correlation between T-Wave Alternans and Cardiac Volume Status via Intrathoracic Impedance MeasurementsJose' Dizon0Kathleen Hickey1Hasan Garan2Division of Cardiology, Department of Medicine and Columbia University Medical Center, Columbia University, New York, NY 10032, USADivision of Cardiology, Department of Medicine and Columbia University Medical Center, Columbia University, New York, NY 10032, USADivision of Cardiology, Department of Medicine and Columbia University Medical Center, Columbia University, New York, NY 10032, USAIntroduction. The presence of T-wave alternans (TWA) has been shown to correlate with a higher risk for sudden cardiac death. The mechanism of TWA may be related to abnormalities in intracellular calcium handling, which is a mechanism in heart failure and associated arrhythmias as well. However, an association between TWA and cardiac volume status has not been demonstrated. Methods Used. We report the case of a 54-year-old man with a dilated cardiomyopathy who had a biventricular defibrillator system implanted with intrathoracic impedance measurement capability. We performed baseline TWA testing, which was normal and was associated with normal clinical status and normal intrathoracic impedance. We followed intrathoracic impedance measurements, and when the measurement suggested volume overload eight months later, we repeated the TWA test. TWA was grossly positive, and volume overload was corroborated with clinical heart failure. The patient was diuresed, and when clinical status and intrathoracic impedance returned to normal a month later, we repeated TWA, which was again negative. Conclusion. This case demonstrates a correlation between cardiac volume status, as measured by intrathoracic impedance measurements, and TWA status. This data suggests that conditions of volume overload such as heart failure could be causally related to increased TWA, perhaps by the common mechanism of altered intracellular calcium handling.http://dx.doi.org/10.1155/2012/167562
spellingShingle Jose' Dizon
Kathleen Hickey
Hasan Garan
Correlation between T-Wave Alternans and Cardiac Volume Status via Intrathoracic Impedance Measurements
Case Reports in Cardiology
title Correlation between T-Wave Alternans and Cardiac Volume Status via Intrathoracic Impedance Measurements
title_full Correlation between T-Wave Alternans and Cardiac Volume Status via Intrathoracic Impedance Measurements
title_fullStr Correlation between T-Wave Alternans and Cardiac Volume Status via Intrathoracic Impedance Measurements
title_full_unstemmed Correlation between T-Wave Alternans and Cardiac Volume Status via Intrathoracic Impedance Measurements
title_short Correlation between T-Wave Alternans and Cardiac Volume Status via Intrathoracic Impedance Measurements
title_sort correlation between t wave alternans and cardiac volume status via intrathoracic impedance measurements
url http://dx.doi.org/10.1155/2012/167562
work_keys_str_mv AT josedizon correlationbetweentwavealternansandcardiacvolumestatusviaintrathoracicimpedancemeasurements
AT kathleenhickey correlationbetweentwavealternansandcardiacvolumestatusviaintrathoracicimpedancemeasurements
AT hasangaran correlationbetweentwavealternansandcardiacvolumestatusviaintrathoracicimpedancemeasurements