COMPARISON OF PERFORMANCE CHARACTERISTICS OF GAMMA CAMERAS WITH SCINTILLATION NaI(TI) AND SEMICONDUCTOR CdZnTe DETECTORS

Objective: In recent years, gamma cameras with semiconductor detectors (CdZnTe) have entered routine practise diagnostic scintigraphic imaging in nuclear medicine. In this study, we aimed to compare the performance characteristics of a gamma camera with a semiconductor detector (CdZnTe) and a conven...

Full description

Saved in:
Bibliographic Details
Main Authors: Armağan Aydın, Füsun Çetin, Mustafa Demir
Format: Article
Language:English
Published: Istanbul University Press 2024-10-01
Series:Sabiad
Subjects:
Online Access:https://cdn.istanbul.edu.tr/file/JTA6CLJ8T5/D434635A432B401D813C17A71915E80D
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850194109346611200
author Armağan Aydın
Füsun Çetin
Mustafa Demir
author_facet Armağan Aydın
Füsun Çetin
Mustafa Demir
author_sort Armağan Aydın
collection DOAJ
description Objective: In recent years, gamma cameras with semiconductor detectors (CdZnTe) have entered routine practise diagnostic scintigraphic imaging in nuclear medicine. In this study, we aimed to compare the performance characteristics of a gamma camera with a semiconductor detector (CdZnTe) and a conventional gamma camera with a NaI(Tl) detector. Material and Methods: In our experimental studies, spatial resolution, energy resolution, and linearity tests were performed using 3 capillary tubes of the same length and thickness, into which the Tc-99m radioisotope with different activities was placed. Sensitivity tests were performed by placing Tc-99m in a plastic Petri dish with a diameter of 3 cm. Scintigraphic images of the capillary tubes and the Petri dish were taken with both gamma cameras under equal geometric conditions. Regions of interest (ROI) were drawn on the images. The activity amount corresponding to the counts in the ROI was determined. Results: The spatial resolution, energy resolution, and sensitivity values of the gamma camera with the CdZnTe detector and the gamma camera with NaI(Tl) detector are respectively: 7.16 mm, 5.1% and 17.5 cps/µCi for CdZnTe, and 13.2 mm, 9.4% and 3.9 cps/µCi for NaI(Tl) µCi respectively. Conclusion: According to the results of our study, it was concluded that the energy resolution, spatial resolution, sensitivity, and linearity properties of the gamma camera with the semiconductor CdZnTe detector are superior to those of the gamma camera with the NaI(Tl) detector.
format Article
id doaj-art-4e876e9334db4900a911fc1d44209a38
institution OA Journals
issn 2651-4060
language English
publishDate 2024-10-01
publisher Istanbul University Press
record_format Article
series Sabiad
spelling doaj-art-4e876e9334db4900a911fc1d44209a382025-08-20T02:14:06ZengIstanbul University PressSabiad2651-40602024-10-017317417910.26650/JARHS2024-1424470123456COMPARISON OF PERFORMANCE CHARACTERISTICS OF GAMMA CAMERAS WITH SCINTILLATION NaI(TI) AND SEMICONDUCTOR CdZnTe DETECTORSArmağan Aydın0https://orcid.org/0000-0002-9126-8381Füsun Çetin1https://orcid.org/0000-0001-9135-2615Mustafa Demir2https://orcid.org/0000-0002-9813-1628İstanbul Üniversitesi-Cerrahpaşa, Istanbul, Turkiyeİstanbul Aydın Üniversitesi, Istanbul, Turkiyeİstanbul Üniversitesi-Cerrahpaşa, Istanbul, TurkiyeObjective: In recent years, gamma cameras with semiconductor detectors (CdZnTe) have entered routine practise diagnostic scintigraphic imaging in nuclear medicine. In this study, we aimed to compare the performance characteristics of a gamma camera with a semiconductor detector (CdZnTe) and a conventional gamma camera with a NaI(Tl) detector. Material and Methods: In our experimental studies, spatial resolution, energy resolution, and linearity tests were performed using 3 capillary tubes of the same length and thickness, into which the Tc-99m radioisotope with different activities was placed. Sensitivity tests were performed by placing Tc-99m in a plastic Petri dish with a diameter of 3 cm. Scintigraphic images of the capillary tubes and the Petri dish were taken with both gamma cameras under equal geometric conditions. Regions of interest (ROI) were drawn on the images. The activity amount corresponding to the counts in the ROI was determined. Results: The spatial resolution, energy resolution, and sensitivity values of the gamma camera with the CdZnTe detector and the gamma camera with NaI(Tl) detector are respectively: 7.16 mm, 5.1% and 17.5 cps/µCi for CdZnTe, and 13.2 mm, 9.4% and 3.9 cps/µCi for NaI(Tl) µCi respectively. Conclusion: According to the results of our study, it was concluded that the energy resolution, spatial resolution, sensitivity, and linearity properties of the gamma camera with the semiconductor CdZnTe detector are superior to those of the gamma camera with the NaI(Tl) detector.https://cdn.istanbul.edu.tr/file/JTA6CLJ8T5/D434635A432B401D813C17A71915E80Dgamma camerasemiconductor detectorcdznteenergy resolutionspatial resolution
spellingShingle Armağan Aydın
Füsun Çetin
Mustafa Demir
COMPARISON OF PERFORMANCE CHARACTERISTICS OF GAMMA CAMERAS WITH SCINTILLATION NaI(TI) AND SEMICONDUCTOR CdZnTe DETECTORS
Sabiad
gamma camera
semiconductor detector
cdznte
energy resolution
spatial resolution
title COMPARISON OF PERFORMANCE CHARACTERISTICS OF GAMMA CAMERAS WITH SCINTILLATION NaI(TI) AND SEMICONDUCTOR CdZnTe DETECTORS
title_full COMPARISON OF PERFORMANCE CHARACTERISTICS OF GAMMA CAMERAS WITH SCINTILLATION NaI(TI) AND SEMICONDUCTOR CdZnTe DETECTORS
title_fullStr COMPARISON OF PERFORMANCE CHARACTERISTICS OF GAMMA CAMERAS WITH SCINTILLATION NaI(TI) AND SEMICONDUCTOR CdZnTe DETECTORS
title_full_unstemmed COMPARISON OF PERFORMANCE CHARACTERISTICS OF GAMMA CAMERAS WITH SCINTILLATION NaI(TI) AND SEMICONDUCTOR CdZnTe DETECTORS
title_short COMPARISON OF PERFORMANCE CHARACTERISTICS OF GAMMA CAMERAS WITH SCINTILLATION NaI(TI) AND SEMICONDUCTOR CdZnTe DETECTORS
title_sort comparison of performance characteristics of gamma cameras with scintillation nai ti and semiconductor cdznte detectors
topic gamma camera
semiconductor detector
cdznte
energy resolution
spatial resolution
url https://cdn.istanbul.edu.tr/file/JTA6CLJ8T5/D434635A432B401D813C17A71915E80D
work_keys_str_mv AT armaganaydın comparisonofperformancecharacteristicsofgammacameraswithscintillationnaitiandsemiconductorcdzntedetectors
AT fusuncetin comparisonofperformancecharacteristicsofgammacameraswithscintillationnaitiandsemiconductorcdzntedetectors
AT mustafademir comparisonofperformancecharacteristicsofgammacameraswithscintillationnaitiandsemiconductorcdzntedetectors