Development of an In-Field Method for the Detection of Barium in Various Water Samples Using Differential Pulse Anodic Stripping Voltammetry
This work presents a reliable, cost-effective, rapid and in-field voltammetric method for the detection of barium. The optimized method consists of an ultrathin mercury film deposited in situ on a glassy carbon electrode in dilute potassium chloride without deoxygenation, using differential pulse an...
Saved in:
| Main Authors: | , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Wiley
2019-01-01
|
| Series: | International Journal of Electrochemistry |
| Online Access: | http://dx.doi.org/10.1155/2019/5813492 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Summary: | This work presents a reliable, cost-effective, rapid and in-field voltammetric method for the detection of barium. The optimized method consists of an ultrathin mercury film deposited in situ on a glassy carbon electrode in dilute potassium chloride without deoxygenation, using differential pulse anodic stripping voltammetry (DP-ASV). Application of the method allowed for the quantitative determination of barium concentration in a variety of waters and brake pad dust samples. Comparative analysis of sample results from DP-ASV with inductively coupled plasma mass spectroscopy (ICP-MS) showed a mean percent difference of 1.8%. |
|---|---|
| ISSN: | 2090-3529 2090-3537 |