Assessment of lead contamination in drinking water in zone I and zone III of Islamabad, Pakistan

Abstract This study assesses the level of Pb contamination in sources of drinking water from Zone I and Zone III of Islamabad, Pakistan, to help identify sources of contamination and quantify associated health risks while providing actionable insights. Altogether, 169 water samples were collected fr...

Full description

Saved in:
Bibliographic Details
Main Authors: Kashaf Waseem, Abdul Saboor Akhtar, Ahsan Nawaz
Format: Article
Language:English
Published: Springer 2025-06-01
Series:Discover Water
Subjects:
Online Access:https://doi.org/10.1007/s43832-025-00231-z
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849688014629896192
author Kashaf Waseem
Abdul Saboor Akhtar
Ahsan Nawaz
author_facet Kashaf Waseem
Abdul Saboor Akhtar
Ahsan Nawaz
author_sort Kashaf Waseem
collection DOAJ
description Abstract This study assesses the level of Pb contamination in sources of drinking water from Zone I and Zone III of Islamabad, Pakistan, to help identify sources of contamination and quantify associated health risks while providing actionable insights. Altogether, 169 water samples were collected from springs and bore water with depths ranging from 17 to 300 feet. The focus lies on the comparison of anthropogenic sources (bore water of Zone III) along with the pipe types (PVC and metal) with the natural source of water (springs of Zone III) to identify the reason for contamination. Pb concentrations were determined using atomic absorption spectrophotometry, with health risk assessments done on HQ and lifetime cancer risk indices. Results showed that Pb levels in Zone III, spring waters were below detection limits at < 0.01 mg/L, which suggests less natural Pb contamination. Zone I from metal pipes showed a median Pb value above 0.1 mg/L, which is beyond WHO’s permissible limit of 0.01 mg/L. Regression analysis revealed that pipe material, water chemistry, and stagnation time were the significant contributors to Pb contamination. Spatial distribution maps indicated that high-risk sectors were H9, G6, and I10 with Pb concentrations of 0.307 mg/L. Health risk assessments indicated high non-carcinogenic and carcinogenic risks, particularly for children in low-income sectors. The PCA highlighted the leading role of anthropogenic sources, specifically corrosion in metal pipes, in driving Pb contamination. This study calls for policy intervention, upgrades and alternatives for pipes, and targeted risk mitigation strategies to promote public health, particularly that of vulnerable populations exposed in high-risk areas.
format Article
id doaj-art-4cb47dd2db0a4ce8a4053b22d77b7cb4
institution DOAJ
issn 2730-647X
language English
publishDate 2025-06-01
publisher Springer
record_format Article
series Discover Water
spelling doaj-art-4cb47dd2db0a4ce8a4053b22d77b7cb42025-08-20T03:22:11ZengSpringerDiscover Water2730-647X2025-06-015112110.1007/s43832-025-00231-zAssessment of lead contamination in drinking water in zone I and zone III of Islamabad, PakistanKashaf Waseem0Abdul Saboor Akhtar1Ahsan Nawaz2Department of Environmental Science, International Islamic UniversityDepartment of Environmental Science, Quaid-I-Azam UniversityDepartment of Environmental Science, Quaid-I-Azam UniversityAbstract This study assesses the level of Pb contamination in sources of drinking water from Zone I and Zone III of Islamabad, Pakistan, to help identify sources of contamination and quantify associated health risks while providing actionable insights. Altogether, 169 water samples were collected from springs and bore water with depths ranging from 17 to 300 feet. The focus lies on the comparison of anthropogenic sources (bore water of Zone III) along with the pipe types (PVC and metal) with the natural source of water (springs of Zone III) to identify the reason for contamination. Pb concentrations were determined using atomic absorption spectrophotometry, with health risk assessments done on HQ and lifetime cancer risk indices. Results showed that Pb levels in Zone III, spring waters were below detection limits at < 0.01 mg/L, which suggests less natural Pb contamination. Zone I from metal pipes showed a median Pb value above 0.1 mg/L, which is beyond WHO’s permissible limit of 0.01 mg/L. Regression analysis revealed that pipe material, water chemistry, and stagnation time were the significant contributors to Pb contamination. Spatial distribution maps indicated that high-risk sectors were H9, G6, and I10 with Pb concentrations of 0.307 mg/L. Health risk assessments indicated high non-carcinogenic and carcinogenic risks, particularly for children in low-income sectors. The PCA highlighted the leading role of anthropogenic sources, specifically corrosion in metal pipes, in driving Pb contamination. This study calls for policy intervention, upgrades and alternatives for pipes, and targeted risk mitigation strategies to promote public health, particularly that of vulnerable populations exposed in high-risk areas.https://doi.org/10.1007/s43832-025-00231-zLead contaminationDrinking water qualityHealth risk assessmentPipe materialsIslamabadPakistan
spellingShingle Kashaf Waseem
Abdul Saboor Akhtar
Ahsan Nawaz
Assessment of lead contamination in drinking water in zone I and zone III of Islamabad, Pakistan
Discover Water
Lead contamination
Drinking water quality
Health risk assessment
Pipe materials
Islamabad
Pakistan
title Assessment of lead contamination in drinking water in zone I and zone III of Islamabad, Pakistan
title_full Assessment of lead contamination in drinking water in zone I and zone III of Islamabad, Pakistan
title_fullStr Assessment of lead contamination in drinking water in zone I and zone III of Islamabad, Pakistan
title_full_unstemmed Assessment of lead contamination in drinking water in zone I and zone III of Islamabad, Pakistan
title_short Assessment of lead contamination in drinking water in zone I and zone III of Islamabad, Pakistan
title_sort assessment of lead contamination in drinking water in zone i and zone iii of islamabad pakistan
topic Lead contamination
Drinking water quality
Health risk assessment
Pipe materials
Islamabad
Pakistan
url https://doi.org/10.1007/s43832-025-00231-z
work_keys_str_mv AT kashafwaseem assessmentofleadcontaminationindrinkingwaterinzoneiandzoneiiiofislamabadpakistan
AT abdulsaboorakhtar assessmentofleadcontaminationindrinkingwaterinzoneiandzoneiiiofislamabadpakistan
AT ahsannawaz assessmentofleadcontaminationindrinkingwaterinzoneiandzoneiiiofislamabadpakistan